Department of Oral and Maxillofacial Surgery Faculty of Dentistry Damascus University Damascus, Syrian Arab Republic
Damascus, Syria
NCT Number: NCT07694388
This randomized controlled triple-blind split-mouth clinical trial was conducted to evaluate the effect of early loading on ultraviolet photofunctionalized dental implants placed in the posterior mandible. Ten patients received a total of 20 implants, with each participant receiving one ultraviolet photofunctionalized implant and one non-photofunctionalized control implant. Ultraviolet photofunctionalization was performed 24 hours before implant placement by an independent investigator. All implants were early loaded 4 weeks after surgery. Implant stability was assessed using Resonance Frequency Analysis (RFA) and expressed as Implant Stability Quotient (ISQ) values at implant placement, 3 weeks, and 4 weeks after surgery. Peri-implant marginal bone loss was evaluated radiographically during a one-year follow-up period. The study compared implant stability and radiographic outcomes between ultraviolet photofunctionalized and conventional implants under early loading conditions.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Damascus, Syria
Dental implants have become a predictable and widely accepted treatment modality for the rehabilitation of partially and completely edentulous patients.
Successful implant therapy depends largely on achieving and maintaining osseointegration between the implant surface and the surrounding bone. Traditionally, implants were left unloaded for several months to allow sufficient healing and osseointegration before functional loading. However, the growing demand for shorter treatment times has encouraged the development of early loading protocols. Early loading of dental implants offers several clinical advantages, including reduced treatment duration, earlier restoration of function and esthetics, and improved patient satisfaction. Nevertheless, successful early loading requires adequate implant stability during the critical healing period. Consequently, considerable research has focused on improving implant surface characteristics to accelerate osseointegration and enhance implant stability. Ultraviolet (UV) photofunctionalization is a surface modification technique that involves exposing titanium implants to ultraviolet light before placement. This process reduces hydrocarbon contamination on the implant surface, increases surface hydrophilicity, and enhances the biological activity of titanium. Previous experimental and clinical studies have suggested that UV photofunctionalization may improve cell attachment, promote bone formation, increase bone-to-implant contact, and enhance implant stability during the early stages of healing. This randomized controlled triple-blind split-mouth clinical trial was conducted to evaluate the effect of early loading on ultraviolet photofunctionalized dental implants placed in the posterior mandible. Ten patients requiring bilateral implant-supported rehabilitation in comparable posterior mandibular sites were included. A total of twenty implants were placed, with each participant receiving one ultraviolet photofunctionalized implant and one non photofunctionalized control implant. Implant allocation was randomized, and ultraviolet photofunctionalization was performed by an independent investigator 24 hours before surgery. Participants, the surgeon/outcome assessor, and the statistician were blinded to treatment allocation throughout the study. All implants were restored using an early loading protocol four weeks after implant placement. Implant stability was evaluated using Resonance Frequency Analysis (RFA) and expressed as Implant Stability Quotient (ISQ) values. Measurements were obtained at implant placement, three weeks after surgery, and four weeks after surgery. In addition, peri-implant marginal bone loss was assessed radiographically during a one-year follow-up period. The split-mouth design was selected to minimize inter-individual variability and allow direct comparison between test and control implants within the same participant. The study aimed to determine whether ultraviolet photofunctionalization could improve implant stability and support the clinical performance of early-loaded dental implants in the posterior mandible.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Dental implants assigned to the experimental arm underwent ultraviolet photofunctionalization 24 hours before implant placement by an independent investigator. The implants were subsequently placed in posterior mandibular edentulous sites and restored using an early loading protocol 4 weeks after surgery
Dental implants assigned to the control arm were placed without ultraviolet photofunctionalization. The implants were inserted in comparable posterior mandibular edentulous sites and restored using the same early loading protocol 4 weeks after surgery
Time frame: At implant placement (baseline), 3 weeks after implant placement, and 4 weeks after implant placement.
Implant stability was measured using Resonance Frequency Analysis (RFA) with the Mega ISQ II device. Stability values were recorded as Implant Stability Quotient (ISQ) scores ranging from 1 to 100, with higher values indicating greater implant stability. Measurements were obtained immediately after implant placement, at 3 weeks, and at 4 weeks postoperatively before early loading.
Time frame: At implant placement (baseline) and one year after early loading.
Peri-implant marginal bone loss was evaluated using standardized periapical radiographs obtained immediately after implant placement and one year after early loading. Measurements were performed by assessing the vertical distance from the implant platform to the first bone-to-implant contact on both mesial and distal aspects of the implant. Bone level changes were calculated and recorded in millimeters (mm), with greater values indicating increased marginal bone loss
Damascus University
Other
Effect of Early Loading on Ultraviolet Photofunctionalized Dental Implants: A Randomized Controlled Triple-Blind Split-Mouth Clinical Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.