Harvard Eye Associates
Laguna Hills, California, 92653, United States
NCT Number: NCT04984590
This early feasibility study aims to improve near vision in subjects 55 years or older who have a clinical diagnosis of Age-Related Macular Degeneration. Subjects must have previously been implanted with either the Alcon Model SN60WF or Model SA60AT intraocular lens at least 6-months prior to receiving the IOPCL (intraocular pseudophakic capsular lens). Subject will be followed for a period of 12-months.
Looking for future studies?
Notify Me55 year and older
All sexes
Interventional
Laguna Hills, California, 92653, United States
This will be a 12-month study, in which a maximum of 10 pseudophakic subjects from up to three clinical sites with a diagnosis of age-related macular degeneration will be enrolled. The IOPCL MAG (intraocular pseudophakic capsular lens magnifier) consists of a 4.5mm diameter optic. The IOPCL MAG is centered above the existing intraocular lens. The IOPCL MAG is designed to improve near vision of the AMD subject by providing magnification of 10 diopters in the central 1.8mm zone of the lens optic.
The primary objective of this study is to determine the stability of the IOPCL-AMD-MAG to successfully adhere to a pseudophakic intraocular lens (PCIOL) without slippage or rotation.
The secondary objective of this study is to determine if the IOPCL-AMD-MAG can improve uncorrected near vision in subjects previously implanted with the Alcon Models SN60WF or SA60AT.
Outcome simulation testing will be performed prior to the subject receiving the IOPCL. To qualify for the study the subject must demonstrate an improvement in uncorrected near visual acuity of 10 letters over baseline.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
-
The IOPCL MAG (intraocular pseudophakic capsular lens magnifier) consists of a 4.5 mm diameter optic. The central 1.8mm of the anterior surface has a power of 10.0 diopters. This IOPCL MAG will be implanted over an Alcon Model SN60WF or SA60AT intraocular lens to improve near vision.
Time frame: 12 Months
Measuring postoperative tilt of the PCIOL and IOPCL MAG complex. Tilt was defined as less than or equal to 10 degrees.
Time frame: 12 Months
Measures the decentration of the IOPCL MAG against the PCIOL. Decentration was defined as the horizontal and vertical distances greater than or equal to 0.25mm or less than or equal to 0.75mm.
Time frame: 12 Months
Proportion of eyes (≥ 75%) able to achieve improvement of 10 letters or more of uncorrected near visual acuity (at 14 cm) at 12 months from baseline
Time frame: 12 months
Proportion of eyes (≥ 50%) able to achieve improvement of 20 letters or more of uncorrected near visual acuity (at 14 cm) at 12 months from baseline
Time frame: 12 months
Proportion of eyes (≥ 75%) able to achieve improvement of 10 letters or more when comparing uncorrected near visual acuity (UCNVA) (at 14 cm) at 12 months from baseline BCNVA (at 30 cm, wearing the appropriate preoperative distance refractive correction in addition to +3.0D add)
Time frame: 12 months
Proportion of eyes (≥ 50%) able to achieve improvement of 20 letters or more when comparing uncorrected near visual acuity (UCNVA) (at 14 cm) at 12 months from baseline BCNVA (at 30 cm, wearing the appropriate preoperative distance refractive correction in addition to +3.0D add)
Time frame: 12 months
Proportion of eyes (≥ 75%) able to achieve improvement of 10 letters or more when comparing best corrected near visual acuity (BCNVA) (at 14 cm) at 12 months from baseline BCNVA (at 30 cm, wearing the appropriate preoperative distance refractive correction in addition to +3.0D add)
Time frame: 12 months
Proportion of eyes (≥ 50%) able to achieve improvement of 20 letters or more when comparing best corrected near visual acuity (BCNVA) (at 14 cm) at 12 months from baseline BCNVA (at 30 cm, wearing the appropriate preoperative distance refractive correction in addition to +3.0D add)
OnPoint Vision Inc
Industry
Early Feasibility Study to Evaluate the Safety and Effectiveness of the Intraoperative Pseudophakic Capsular Lens Magnifier for Age-Related Macular Degeneration (IOPCL AMD-MAG) for Secondary Implantation in the Capsular Bag to Improve Near Vision in Subjects With Age-Related Macular Degeneration After Cataract Surgery
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05904444
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Eye Diseases
Guangzhou, Guangdong, China
View Trial DetailsNCT03728660
Eye Diseases, Low Vision
Baltimore, Maryland, United States
View Trial DetailsNCT07577219
Blindness, Blindness, Cortical
Boston, Massachusetts, United States
View Trial DetailsNCT04066075
Eye Diseases, Low Vision
Fullerton, California, United States
View Trial Details