Skip to main content
OpenTrials
Recruiting

NCT Number: NCT07097740

Early Feasibility Study of Surgical Implantation of a Polymer Prosthetic Mitral and Aortic Valve

The goal of this clinical trial is to explore the early feasibility, initial safety, and efficacy of surgical implantation of a polymer prosthetic heart valve in patients requiring either mitral valve replacement or aortic valve replacement.

The main question it aims to answer is:

-- What is the rate of valve-related complications, including thromboembolism, valve thrombosis, severe perivalvular leak, severe bleeding, and endocarditis, at 12 months post-operation?

Participants will undergo:

* Surgical implantation of a polymer prosthetic valve (mitral valve replacement for mitral valve group and aortic valve replacement for aortic valve group). * Regular follow-up visits at 30 days, 3-6 months, and 12 months post-operation to evaluate clinical outcomes, including echocardiographic assessment and clinical event monitoring.

Recruiting

Interested in participating?

Request Info

Key information

Age range

50 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University

Shanghai, Shanghai Municipality, 200000, China

Location status: Recruiting

Location contact

Chunsheng Wang, MD

PRINCIPAL_INVESTIGATOR

Lai Wei, MD

CONTACT

[email protected]

021-51371990

Lai Wei, MD

SUB_INVESTIGATOR

About this study

This is a prospective, exploratory, single-center clinical study designed to assess the early feasibility and initial safety of an investigational polymer prosthetic heart valve. A total of 10 patients will be enrolled, with 5 patients assigned to the mitral valve replacement group and 5 patients to the aortic valve replacement group.

Primary outcomes include the occurrence of valve-related complications within 12 months, such as thromboembolism, valve thrombosis, severe perivalvular leak, severe bleeding, and endocarditis.

Secondary outcomes include immediate device success rate, valve hemodynamic performance, comprehensive safety event evaluations (e.g., all-cause mortality, all-cause reoperation, valve extraction, and structural or non-structural valve dysfunction), cardiac functional classification (NYHA), and quality of life assessments (Kansas City Cardiomyopathy Questionnaire, KCCQ).

Eligible participants are patients requiring mitral or aortic valve replacement, capable of undergoing extracorporeal circulation and anticoagulation therapy, and who have provided informed consent.

Exclusion criteria

include patients with prior valve replacement surgery (except transcatheter mitral valve edge-to-edge repair), urgent/emergency procedures, significant comorbidities (e.g., recent stroke or myocardial infarction, severe liver/kidney dysfunction, active infections), severe coagulation disorders, allergies to valve materials, substance abuse issues, psychiatric disorders, or anticipated life expectancy under 12 months. Patients who drop out after valve implantation will not be replaced.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adults requiring surgical replacement of either mitral or aortic valve
  • Capable of undergoing cardiopulmonary bypass
  • Able to tolerate anticoagulation therapy
  • Able to understand study purpose, willing to provide informed consent and comply with follow-up

Exclusion criteria

  • History of previous cardiac valve surgery or percutaneous valve replacement, including surgical aortic or mitral valve replacement (excluding Percutaneous Balloon Mitral Valvuloplasty [PBMV], which is permitted).
  • Requirement for urgent or emergency cardiac surgery.
  • Planned concurrent aortic valve surgery or combined valve procedure (e.g., simultaneous aortic and mitral valve surgery).
  • Scheduled coronary artery bypass graft (CABG) during the same admission.
  • Anticipated need for additional non-valve cardiac surgery within 12 months.
  • Active systemic infection, including pneumonia or infective endocarditis.
  • Intracardiac thrombus detected on echocardiography or imaging.
  • Stroke or transient ischemic attack within the prior 3 months.
  • Myocardial infarction, unstable coronary syndrome, or coronary revascularization within the prior 3 months.
  • Severe comorbidities with expected life expectancy <12 months, including Child-Pugh C liver disease, end-stage malignancy, or advanced pulmonary disease.
  • Participation in another interventional clinical trial involving investigational devices or drugs.
  • Anatomical risk factors such as ascending aortic aneurysm (≥50 mm), bicuspid aortic valve with ascending aorta ≥45 mm, or other high-risk features identified on imaging.
  • Left ventricular ejection fraction (LVEF) ≤35%, indicating severe systolic dysfunction.
  • Severe renal insufficiency, e.g., estimated GFR <30 mL/min/1.73 m² or requirement for chronic dialysis.
  • Coagulopathy or active bleeding disorders, e.g., INR >1.5 without anticoagulation therapy.
  • Hematologic abnormalities: hematocrit <30%, hemoglobin <100 g/L, platelet count <100 × 10⁹/L, or WBC <4 × 10⁹/L or >10 × 10⁹/L.
  • History of substance abuse, chronic alcoholism, or significant psychiatric illness impairing study compliance.
  • Preoperative or intraoperative anatomical unsuitability of the valve apparatus or cardiac structure.
  • Known allergy or hypersensitivity to polyurethane, polyester, or sulfonate-based biomaterials used in the valve prosthesis.
  • Withdrawal from the study after valve implantation (such participants are not allowed to re-enroll).

Treatment and study plan

Polymer Prosthetic Heart Valve

Device

Surgical implantation of polymer prosthetic valve.

Primary outcomes

  1. 12-Month Incidence of Valve-related Complications

    Time frame: 12 months post-operation

    Evaluate the incidence of valve-related complications at 12 months post-operation, including thromboembolism, valve thrombosis, severe perivalvular leak, severe bleeding, and endocarditis.

Secondary outcomes

  1. Immediate Device Success Rate

    Time frame: Immediately post-operation

    Proportion of participants achieving successful device implantation without intraoperative complications.

  2. Valve Hemodynamic Performance 1 Mean Transvalvular Gradient at 12 months

    Time frame: 12 months post-operation

    Mean pressure gradient across the valve measured by echocardiography (unit: mmHg).

  3. Valve Hemodynamic Performance2 Effective Orifice Area (EOA) at 12 months

    Time frame: 12 months post-operation

    Effective orifice area of the implanted valve measured by echocardiography (unit: cm²).

  4. Safety Outcomes and Adverse Events

    Time frame: Up to 12 months post-operation

    Incidence of safety-related events including all-cause mortality, all-cause reoperation, valve extraction, valve thrombosis, severe bleeding, severe perivalvular leak, structural and non-structural valve deterioration, hemolysis, endocarditis, and any other serious adverse events.

  5. Cardiac Function Classification (NYHA)

    Time frame: 12 months post-operation

    Assess participants' cardiac function using New York Heart Association (NYHA) classification.

  6. Kansas City Cardiomyopathy Questionnaire (KCCQ) Overall Summary Score at 12 months

    Time frame: 12 months post-operation

    Quality of life assessed using the Kansas City Cardiomyopathy Questionnaire (KCCQ).

    The KCCQ is a 23-item questionnaire measuring health status in heart failure patients, scored from 0 to 100, where higher scores indicate a better health status.

  7. Valve Hemodynamic Performance 3 Paravalvular Leakage Severity at 12 months

    Time frame: 12 months post-operation

    Severity of paravalvular leakage (PVL) assessed by echocardiography, classified as None/Trace, Mild, Moderate, or Severe.

Study contacts

Contact information is provided by the study sponsor or research team.

Chunming Du, Medical Master

CONTACT

Lai Wei, MD

CONTACT

[email protected]

021-51371990

Sponsors and collaborators

Lead sponsor

Mitrassist Lifesciences Limited Co., Ltd.

Industry

Collaborators

  • Shanghai Zhongshan Hospital

Registry information

Official study title

A Prospective Early Feasibility Clinical Study of Surgical Implantation of a Polymer Prosthetic Heart Valve

Acronym: POLYVALVE-FIH

Important dates

Study start
2025
Primary completion
2026
Study completion
2027
First posted
Jul 31, 2025
Registry last updated
Jul 31, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.