University College London Hospitals NHS Foundation Trust
London, NW1 2PG, United Kingdom
Location status: Recruiting
Location contact
Manish Chand, MBBS FRCS PhD
CONTACT
NCT Number: NCT05064124
The purpose of the study is to assess whether the AI characterisation system of the CADDIE device improves the endoscopists accuracy in the optical diagnosis of diminutive colorectal polyps in the bowel during colonoscopy. Participants will either have a colonoscopy with the assistance of the CADDIE device characterisation AI system ("intervention group") or have a colonoscopy in line with routine clinical practice i.e., without the CADDIE device characterisation AI system ("control group"). The randomisation method of this trial will allocate enrolled participants to the "intervention" group and to the "control" group by a technique similar to flipping a coin.
Interested in participating?
Request Info18 year and older
All sexes
Observational
London, NW1 2PG, United Kingdom
Location status: Recruiting
Manish Chand, MBBS FRCS PhD
CONTACT
The CADDIE system comprises a computer attached to the output of the endoscopy stack and a screen which shows the normal video output of the colon in real-time. Using artificial intelligence (AI) software, it highlights the characteristics of a polyp to help the endoscopist in their optical diagnosis of the polyp histology. Pressing on a foot pedal, which is connected to the computer, presents the information from the AI software to the user as an overlay on the endoscopy screen in text format.
The CADDIE device is capable of recording the video output of the colon in real-time irrespective of whether the CADDIE's AI system is active.
In the endoscopist recruitment phase, we will identify endoscopists expertise and experience in colonoscopy.
In the study phase of the trial, the endoscopist will be kept the same for the CADDIE and control arm. At the beginning of each procedure, participant information will be entered into an electronic system (Redcap) which will generate a random allocation into one of two arms. The CADDIE arm involves a colonoscopy assisted by the CADDIE AI system (i.e., AI software). The control arm is a colonoscopy without the CADDIE's polyp characterisation AI system (i.e., standard practice). Each endoscopist will have the CADDIE device present during all endoscopy lists and will record all procedures in both CADDIE and control arms. The CADDIE's polyp characterisation system (i.e., AI software) will only be active in the CADDIE arm. The recordings in the control arms will allow an extra post-hoc assessment of how CADDIE might have performed compared to the actual assessment by the endoscopist.
In both arms of the trial, for each polyp the endoscopist detects, they will:
Polyps are to be measured using an instrument of known size. For polyps measured to be <10mm, the endoscopist will capture a still image of the polyp in both white light and Narrow Band Imaging (NBI) or equivalent imaging modality.
The endoscopist will optically diagnosis polyps <10mm, stating whether the diagnosis is made with high or low confidence.
Management of rectosigmoid hyperplastic polyps will be standardised. Rectosigmoid polyps that are optically diagnosed as hyperplastic by the endoscopist will be resected/biopsied. If multiple rectal hyperplastic polyps are optically diagnosed by the endoscopist, a maximum of 5 will be resected/biopsied for histopathology.
Each polyp resected (regardless of size) must be labelled according to instructions of the Specimen Handling SOP. Each unique polyp ID will be logged in chronological order on a per colonoscopy basis and sent for histopathology. Histopathology will be referenced as the ground truth for polyp diagnosis and characterisation.
Documentation will be made in the endoscopy report of polyp site, size, morphology, segmental Boston Bowel Preparation Score (BBPS). A photograph will also be taken of the caecum and stored in the endoscopy report.
Populate the optical diagnosis CRF at the end of the procedure with the polyp ID of each polyp sample (regardless of size), their optical diagnosis of each polyp <10mm in size and whether their optical diagnosis was made with high or low confidence.
In the CADDIE arm, the endoscopist presses the foot pedal once they have frozen an image of the polyp in the endoscopy screen in narrow band imaging (NBI) mode. This will output the CADDIE's characterisation of the polyp. Using this information and the endoscopist's own assessment, the endoscopist will log an optical diagnosis of the polyp and the confidence of their diagnosis (high or low). In the control arm, the endoscopist optically diagnoses the polyps without CADDIE's polyp characterisation function. The optical diagnosis will be assessed against the polyp histopathology which will be referred as the ground truth. Post-hoc analysis of the recorded footage will allow for comparison with the CADDIE generated polyp characterisation.
Safety of the device will be assessed through monitoring of adverse events. Acceptability will be assessed through a qualitative questionnaire for the endoscopist, endoscopy nurse and participant in addition to measuring endoscopy markers such as caecal intubation time, procedural time, withdrawal time.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 1 year
The primary endpoint will be the proportion of diminutive colorectal polyps optically diagnosed correctly by endoscopists (correct optical diagnoses divided by total number of diminutive polyps), expressed as a percentage, in the CADDIE arm compared to the control arm, with the polyp histopathology being referenced as the ground truth.
Time frame: 1 year
The endpoint will be the proportion of diminutive rectosigmoid colorectal polyps optically diagnosed correctly by endoscopists (correct optical diagnoses divided by total number of diminutive rectosigmoid polyps), expressed as a percentage, in the CADDIE arm compared to the control arm, with the polyp histopathology being referenced as the ground truth.
Time frame: 1 year
The endpoint will be the NPV in optically diagnosing rectosigmoid diminutive adenomas in the CADDIE arm compared to the control arm, with the polyp histopathology being referenced as the ground truth.
Time frame: 1 year
The concordance of colonoscopy surveillance intervals in the CADDIE arm when using endoscopists CADDIE assisted OD in comparison to histopathology derived intervals (ground truth) - per patient analysis.
Time frame: 1 year
The concordance of colonoscopy surveillance intervals in the control arm when using endoscopists OD without the CADDIE system in comparison to histopathology derived intervals (ground truth) - per patient analysis.
Time frame: 1 year
To compare the concordance of colonoscopy surveillance intervals against histopathology derived surveillance intervals (ground truth) in the CADDIE arm with the control arm (expressed as a percentage) - per patient analysis.
Time frame: 1 year
Compare the rate of endoscopists high-confidence optical diagnosis when using the CADDIE system compared to without.
Time frame: 1 year
Frequency of adverse events based on maximum severity of event for each participant in each arm. Adverse events will be recorded at 30 days post-procedure.
Time frame: 1 year
i) Compare caecal intubation time in both arms of the study. ii) Compare caecal intubation rate in both arms of the study. iii) Endoscopist/endoscopy nurse/patient experience and acceptability of the CADDIE system assessed by qualitative questionnaire.
Contact information is provided by the study sponsor or research team.
Rawen Kader, MBBS MRCP
CONTACT
Sharon Cheung, MSc
CONTACT
University College, London
Other
Acronym: EARTHSCAN
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04325815
Adenoma Colon, Colon Polyp
London, United Kingdom
View Trial DetailsNCT05551052
Adenoma, Adenomas Colon
Chula Vista, California, United States
View Trial DetailsNCT04889352
Colo-rectal Cancer, Colon Polyp
Winnipeg, Manitoba, Canada
View Trial DetailsNCT03688906
Adenoma, Adenoma Colon
Huntsville, Alabama, United States
View Trial Details