University of Wisconsin
Madison, Wisconsin, 53792, United States
NCT Number: NCT03863509
This study is designed to enhance the understanding of the possible health effects of e-cigarette use by relating the acute and long-term use of e-cigarettes and conventional cigarettes ("products") to well-validated cardiovascular and pulmonary disease biomarkers. Participants will be enrolled in 3 groups: exclusive e-cigarette users, exclusive cigarette smokers, and a control group of never-users. Participants can expect up to 4 weeks of study participation.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Madison, Wisconsin, 53792, United States
E-cigarette use is increasing rapidly in the United States, especially amongst youth, underscoring the vital need to improve understanding of its health risks. Relevant data could inform policy, guide public health and clinical intervention efforts, and inform individuals who might use or who are using this product. This research will significantly enhance the understanding of the possible health effects of e-cigarette use by relating the acute and long-term use of e-cigarettes and conventional cigarettes ("products") to well-validated cardiovascular and pulmonary disease biomarkers. 3 different "use-groups" of participants will be enrolled: exclusive e-cigarette users (n=165), exclusive cigarette smokers (n=165), and a "control" group of never-users (n=110). These groups reflect the primary decisions that people can make regarding their future tobacco use: to continue to smoke cigarettes, to switch to e-cigarettes, or to avoid tobacco use entirely. It is essential that smokers and health care providers have accurate information on the health effect of these choices.
[Additionally, 100 participants will be invited to be part of an epigenetics sub-study (50 E-cig users, 25 smokers and 25 controls), prior to smoking, an additional 16 ml of blood will be collected in Vacutainer cell separation tubes for peripheral blood monocyte (PBMC) Isolation containing sodium citrate.]
Product use will be related to well-validated biomarkers that sensitively and reproducibly reflect mechanisms, injury, and/or future risk related to cardiovascular or pulmonary disease. Biomarkers will be related to: 1) acute product use in the laboratory (exposure challenges), 2) lifetime history of product use, and/or 3) real-time measures of product use in participants' daily lives. The primary cardiovascular biomarkers are brachial artery flow-mediated dilation (a measure of endothelial function) and carotid intima-media thickness, a measure of subclinical arterial injury and atherosclerosis. The primary pulmonary disease biomarkers will be measures of lung volumes and flow rates (Forced Expiatory Volume exhaled in the first second (FEV1), Forced vital capacity (FVC), FEV1/FVC) obtained by spirometry. Treadmill exercise stress testing will be performed (to assess aerobic fitness), electrocardiography (to measure heart rate variability, HRV), and measure heart rate, blood pressure, lipids, HgbA1c, and inflammation/oxidation markers (leukocyte count, C-reactive protein, urinary F2 isoprostanes and exhaled nitric oxide). This research will show how product use-groups differ in response to acute product use and long-term use as they are related to key cardiovascular and pulmonary biomarkers. Objective measures of product use include exhaled CO and plasma nicotine/cotinine and urinary nicotine/cotinine concentrations. History of product use within use-groups will be related to biomarker status.
The proposed research will yield vital and comprehensive data regarding product use, subclinical arterial injury, atherosclerosis burden, arterial and pulmonary function, cardiac and aerobic fitness, cardiac autonomic regulation, systemic and pulmonary inflammation, and oxidative stress, as well as other key outcomes. These data will serve as a foundation for future longitudinal investigations of e-cigarette health effects and will inform public policy decisions, clinical intervention, and patient guidance regarding e-cigarettes.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
smokes daily
E-cigarette usage >/= 5 days/week
Other names: E-cig, Vape
Time frame: V2 up to 4 weeks from enrollment visit, fasting
Brachial Artery Flow-Mediated Dilation is a primary cardiovascular biomarker and a measure of endothelial function that will be assessed before and after an acute exposure challenge. These are pre-challenge values.
Ultrasound based changes in brachial artery diameter after a forearm cuff occlusion (250mmHg) for 5 minutes. FMD is the percent change in brachial diameter measured 60 to 90 seconds post cuff release compared to its resting diameter. A higher % dilation is an indication of better endothelial function.
Time frame: V2 up to 4 weeks from enrollment visit , fasting, pre challenge session
FEV1 is a primary measure of pulmonary disease obtained by spirometry that will be assessed before and after an acute exposure challenge. These are per-challenge values
Time frame: V2 up to 4 weeks from enrollment visit, only done pre-challenge
Carotid Intima-Media Thickness is a cardiovascular biomarker and a measure of sub-clinical arterial injury and atherosclerosis as a result of chronic exposure. IMT will be measured via ultrasonography.
Time frame: During Visit 2 (1 - 4 weeks post enrollment) before and after smoking/vaping challenge and for controls after a 10 minute break
Visit 2 was scheduled up to 4 weeks from enrollment visit, fasting.. They came in the morning after 8 hours of fasting and refraining from nicotine products. Systolic blood pressure (left brachial artery using an oscillometric method) was measured supine, after 10 minutes rest ("Pre") and repeated after they underwent smoking or vaping changes. The "post challenge" blood pressures were recorded 15-20 minutes post end of exposure. For controls, all measurements were repeated in the same order after a 10 minute break.
Time frame: before and after smoking/vaping challenge during Visit 2 (up to 4 weeks from enrollment)
Participants returned for V2 up to 4 weeks from enrollment visit, fasting. They came in the morning after 8 hours of fasting and refraining from nicotine products. Diastolic blood pressure (left brachial artery using an oscillometric method) was measured supine, after 10 minutes rest ("Pre") and repeated after they underwent smoking or vaping changes. The "post challenge" blood pressures were recorded 15-20 minutes post end of exposure. For controls, all measurements were repeated in the same order after a 10 minute break.
Time frame: Before and after smoking/vaping challenge during Visit 2 (up to 4 weeks from enrollment)
Visit 2 was scheduled up to 4 weeks from enrollment visit, fasting. Participants attended fasting and refraining from nicotine products for at least 8 hours prior. All visits were in the morning. Pre-challenge heart rate measured supine, after 10 minutes rest from blood pressure monitor (dinamap). The post challenge heart rates were recorded 15-20 minutes post end of exposure to smoking or vaping challenge completion or in the case of controls after a 10 minute break.
Time frame: before and after smoking/vaping challenge during Visit 2 (up to 4 weeks from enrollment)
Visit 2 was scheduled up to 4 weeks from enrollment visit. Participants attended fasting and refraining from nicotine products for at least 8 hours prior. All visits were in the morning. Pre-challenge brachial artery diameter imaged with ultrasound after resting supine for 10 minutes before and repeated 15-20 minutes after smoking/vaping challenge ended. or in the case of controls after a 10 minute break.
Time frame: Testing was done after 10 minutes rest and fasting for pre- and post-challenge. The post challenge FMD were recorded 15-20 minuted after end of exposure (up to 4 weeks from enrollment)
Visit 2 was scheduled up to 4 weeks from enrollment visit. Participants attended fasting and refraining from nicotine products for at least 8 hours prior. All visits were in the morning. Pre-challenge ultrasound of brachial artery diameter imaged with ultrasound after resting supine for 10 minutes before and repeated 15-20 minutes after smoking/vaping challenge ended. or in the case of controls after a 10 minute break. The FMD protocol includes measuring % change in resting diameter after 60-90 seconds post fore-arm cuff occlusion release.
Time frame: During V2 (scheduled up to 4 weeks from enrollment) and obtained after 10 minutes of supine rest, before and after smoking/vaping challenge
Expressed as a percentage of beats (supine recordings had be 5 minutes or longer to be valid). We used the SphygmoCor system for these recordings (Atcor medical). Participants attended V2 1-2 weeks after enrollment visit. They came in the morning fasting and refraining from nicotine for at least 8 hours. Heart rate variability was recorded supine for 10 minutes or more, pre and post smoking/vaping challenge. For controls is was repeated after a 10-minute break.
Time frame: heart rate variability recordings of at least 10 minutes per-challenge and 15 minutes post-challenge (up to 4 weeks from enrollment)
Participants attended V2 up to 4 weeks after enrollment visit. They came in the morning fasting and refraining from nicotine for at least 8 hours. Heart rate variability was recorded supine for 10 minutes or more, pre and post smoking/vaping challenge. For controls it was repeated after a 10 minute break.
Time frame: Ratio was measured pre- and post- smoking/vaping challenge after completion of the 10 minutes of heart rate variability measures (up to 4 weeks from enrollment)
We used the SphygmoCor system for these recordings (Atcor medical). Participants attended V2 up to 4 weeks after enrollment visit. They came in the morning fasting and refraining from nicotine for at least 8 hours. Heart rate variability standing ratio was assessed pre and post smoking/vaping challenge. For controls is was repeated after a 10-minute break. Ratio between maximal heart rate after abrupt standing from a supine position and the subsequent lowest heart rate value within 40 seconds of peak.
Time frame: before and after smoking/vaping challenge during Visit 2 (1-4 weeks after enrollment visit)
maximum amount of air that the subject can forcibly expel during the first second following maximal inhalation, expressed as a percentage of the predicted normal values in the population. Participants attended V2 1-4 weeks after enrollment. They came in the morning, fasting and refraining from nicotine exposure for at least 8 hours prior. Pre-challenge spirometry was performed sitting before all other tests and repeated within 15 minutes after smoking/vaping challenge.
Time frame: before and after smoking/vaping challenge during Visit 2 Visit 2 which was scheduled 1 to 4 weeks from enrollment visit, fasting
Amount of air that can be forcibly exhaled after taking the deepest breath possible expressed as a predicted percentage from the normal population. Participants attended V2 1-4 weeks after enrollment. They came in the morning, fasting and refraining from nicotine exposure for at least 8 hours prior. Pre-challenge spirometry was performed sitting before all other tests and repeated within 15 minutes after smoking/vaping challenge.
Time frame: before and after smoking/vaping challenge during Visit 2 (1-4 weeks after enrollment visit)
The post challenge spirometry was recorded <15 minutes post end of exposure. Participants attended V2 1-4 weeks after enrollment. They came in the morning, fasting and refraining from nicotine exposure for at least 8 hours prior. Pre-challenge spirometry was performed sitting before all other tests and repeated within 15 minutes after smoking/vaping challenge.
Time frame: Spirometry performed pre-challenge and within 15 minutes post-challenge (up to 4 weeks from enrollment)
Participants attended Visit 2 (1-4 weeks after enrollment visit). They came in the morning, fasting and refraining from nicotine exposure for at least 8 hours prior. Pre-challenge spirometry was performed sitting before all other tests and repeated within 15 minutes after smoking/vaping challenge.
Time frame: before and after less than 15 minutes from smoking/ vaping product (up to 4 weeks from enrollment)
Participants attended V2 1-4 weeks after enrollment. They came in the morning, fasting and refraining from nicotine exposure for at least 8 hours prior. Pre-challenge FeNO was obtained sitting and repeated within 15 minutes after smoking/vaping challenge.
Time frame: Participants attended V2 generally 1-4 weeks after enrollment with a window that allowed up to 4 weeks after enrollment
Heart Rate pre-acute exposure challenge was obtained after resting supine for 10 minutes during V2 in the morning, fasting and refraining from nicotine exposure for at least 8 hours prior.
Time frame: V2 two was generally scheduled 1-4 weeks after enrollment visit with a window up to 4 weeks. HRV measures obtained after resting supine for 10 minutes
Heart Rate Variability PNN50(%) measured before an exposure challenge. Participants attended visit 2 fasting and refraining from nicotine for at least 8 hours.
Time frame: V2 was up to 4 weeks from enrollment visit, after resting supine for 10 minutes
Blood Pressure measured using the oscillometric technique before an acute exposure challenge following standardized protocol. After resting supine for 10 minutes blood pressure was measured on both arms and the average of the last two values was used.
Time frame: recordings obtained during V2 in the morning, fasting and refraining from nicotine for at least 8 hours. This visit was generally 1-2 weeks after enrollment date with a window up to 4 weeks
Forced Vital Capacity is a measure of how much air can be exhaled forcefully obtained by spirometry pre acute exposure challenge.
Time frame: recordings obtained during V2 in the morning, fasting and refraining from nicotine for at least 8 hours. This visit was generally 1-2 weeks after enrollment date with a window up to 4 weeks
Fractional Exhaled Nitric Oxide is a measure of airway inflammation measured before an acute exposure challenge.
Time frame: v2 was generally 1-2 weeks after enrollment visit, with a window up to 4 weeks from V1
Root mean square of standard deviation of rr intervals. Obtained fasting and refraining from nicotine exposure using the Sphymocor system. We used 10 or more minutes of supine data to derive heart rate variability measures.
Time frame: v2 was generally 1-2 weeks after enrollment visit, with a window up to 4 weeks from V1
Analysis of radial pressure wave forms allows for non-invasive estimation of central aortic pressures, accounting for pressure amplification and the amplitude of the arterial pulse wave as it moves through arteries away from the heart. The Atcor Sphygmacor system can derive central aortic pressures from radial tracings using a validated transfer function. This computation is performed using the pulse wave analysis (PWA) mode. Pulse Wave Analysis via radial tonometry was obtained as a measure of chronic exposure.
Time frame: Treadmill test done only once at the end of v2 after completion of all other post-challenge assessment tests. V2 was scheduled 1-4 weeks from enrollment vist
An ETT to determine exercise capacity will be completed as a measure of chronic exposure. Peak metabolic equivalents (METs, 1 MET=3.5 ml O2 uptake/kg body weight/minute) were determined at all exercise stages, peak exercise, and 1-minute post-exercise.
Time frame: V2 was generally 1-2 weeks after enrollment with a window up to 4 weeks from V1, recorded after resting supine for 10 minutes
During V2, Diastolic Blood Pressure was measured using the oscillometric technique before an acute exposure challenge following a standardized protocol. After resting supine for 10 minutes blood pressure was measured on both arms and the average of the last two values was used. Participants attended v2 in the morning, fasting and refraining from nicotine products for at least 8 hours.
Time frame: During V2 (1-4 weeks after enrollment visit) the treadmill stress test was done last, following Nicotine-containing product challenge (users) or pretend 10 minute exposure for controls
Peak RPP was calculated by multiplying maximun heart rate during exercise by systolic blood pressure as a reliable assessment of cardiac workload
Time frame: During V2 (1-4 weeks after enrollment visit) the treadmill stress test was done last, following Nicotine-containing product challenge (users) or 10 minute pretend exposure for never-users
Measure of maximal exercise capacity adjusted for age, calculated as max heart rate during treadmill divided by (220 minus the participant's age in yrs)
Time frame: During V2 (1-4 weeks after enrollment visit) the treadmill stress test was done last, following Nicotine-containing product challenge (users) or pretend 10 minute exposure for controls
Difference in heart rate 60 seconds post treadmill minus maximal heart rate during treadmill..
University of Wisconsin, Madison
Other
E-Cigarette Effects on Markers of Cardiovascular and Pulmonary Disease Risk (Aka CLUES - Cardiac and Lung E-cig Smoking Study)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05671380
Behavior, Cardiovascular Diseases
Minneapolis, Minnesota, United States
View Trial DetailsNCT06372899
Behavior, Cigarette Smoking
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT06534905
Behavior, Chemically-Induced Disorders
Baltimore, Maryland, United States
View Trial DetailsNCT07213947
Behavior, Nicotine Pouch Self-Administration
Lexington, Kentucky, United States
View Trial Details