Dynamic Electronic Filter for Arterial Waveform Distortion

Invasive blood pressure (IBP) is the gold standard for arterial pressure (AP) monitoring in critically ill patients. Nevertheless, IBP may be affected by underdamping/resonance artifacts, that eventually lead to AP overestimation. In these cases, when a pulse contour method is applied, wrong hemodynamic data are also delivered by the monitor. In order to overtake this issue, MostCareUp (a PCM powered by Pressure Recording Analytical Method, PRAM), has been implemented with a dynamic electronic filter (EFMC) that automatically corrects the resonant AP waveform.

In order to test the EFMC, the electronically corrected AP and the derived cardiac output were compared with respective raw data corrected with the Accudynamic, an adjustable damping device specifically manufactured for normalizing the pressure waveform (in our study: the reference method).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Azienda Ospedaliero-Universitaria Careggi

Florence, 50134, Italy

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • ICU patients with invasive blood pressure (radial artery) affected by underdamping/resonance artifacts;

Exclusion criteria

  • Arrhythmias

Treatment and study plan

MostCareUp

Device

Pressure transducers have been connected to the MostCareUp and the hemodynamic parameters compared as follows: no filter, electronic filter, no electronic filter plus Accudynamic (our reference system). Invasive pressure values have been then compared with the non-invasive ones.

Primary outcomes

  1. The present study was aimed to test the MostCareUp electronic filter

    Time frame: 15 minutes

    To test the electronic filter comparing the electronically corrected arterial pressure and the derived cardiac output values with those corrected with the Accudynamic, a mechanical adjustable damping device commonly used in clinical practice.

Sponsors and collaborators

Lead sponsor

University of Florence

Other

Registry information

Official study title

Arterial Pressure Waveform Distortion: a New Dynamic Electronic Filter for Automatic Correction of Underdamping/Resonance Artifact. A Prospective Study

Important dates

Study start
2017
Primary completion
2018
Study completion
2018
First posted
Dec 22, 2021
Registry last updated
Jan 12, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.