Dynamic Arterial Elastance Measured by Uncalibrated Pulse Contour Analysis Predicts Arterial Pressure Response to a Decrease in Norepinephrine

Dynamic arterial elastance (Eadyn) has been proposed as an indicator of arterial tone that can predict norepinephrine-dependent arterial pressure. Eadyn is calculated using the ratio of respiratory pulse pressure variation (PPV) over the respiratory stroke volume variation (SVV). Guinot et al demonstrated a decrease in the duration of norepinephrine treatment with the use of Eadyn. To date, studies that have validated Eadyn at bedside have used cardiac output (CO) calibrated pulse contour analysis (PiCCO™, Pulsion™) or oesophageal doppler. Such monitoring systems need dedicated and specific arterial line and venous access that may limit their use at bedside. In addition to CO calibrated pulse contour analysis, CO uncalibrated pulse contour analysis has been developed and is considered less invasive. Nevertheless, one limitation of the latter CO monitoring is inaccuracy of CO measurement in patients who are being treated with norepinephrine. These limitations may affect the predictability of Eadyn. We conducted a prospective study in a university hospital ICU. Patients with vasoplegic syndrome for whom the intensive care physician planned to decrease the norepinephrine dosage were included. Hemodynamic and uncalibrated pulse contour analysis (Volume view, FloTrac, Edwards Lifescience, Irvine) values were obtained before and after decreasing the norepinephrine dosage. Responders were defined by a >10% decrease in mean arterial pressure (MAP).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

CHU Amiens-Picardie

Amiens, 80054, France

About this study

  • Background : Dynamic arterial elastance (Eadyn) has been proposed as an indicator of arterial tone that can predict norepinephrine-dependent arterial pressure. Eadyn is calculated using the ratio of respiratory pulse pressure variation (PPV) over the respiratory stroke volume variation (SVV). Guinot et al demonstrated a decrease in the duration of norepinephrine treatment with the use of Eadyn. To date, studies that have validated Eadyn at bedside have used cardiac output (CO) calibrated pulse contour analysis (PiCCO™, Pulsion™) or oesophageal doppler. Such monitoring systems need dedicated and specific arterial line and venous access that may limit their use at bedside. In addition to CO calibrated pulse contour analysis, CO uncalibrated pulse contour analysis has been developed and is considered less invasive. Nevertheless, one limitation of the latter CO monitoring is inaccuracy of CO measurement in patients who are being treated with norepinephrine. These limitations may affect the predictability of Eadyn.
  • Purpose : To date, no study has evaluated the ability of Eadyn measured by uncalibrated pulse contour analysis to assess arterial pressure response to a decreased dose of norepinephrine. We tested the hypothesis that Eadyn calculated from uncalibrated pulse contour analysis predicts the arterial-pressure response to a norepinephrine decrease in patients treated with norepinephrine

Who can participate

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Inclusion criteria

were all consecutive patients with a diagnosis of vasoplegic syndrome, treated with norepinephrine, for whom the attending physician decided to decrease the norepinephrine dosage. The vasoplegic syndrome was defined as persistent arterial hypotension with normal or high cardiac output and low systemic vascular resistance

Exclusion criteria

Exclusion criteria

were patients treated with epinephrine and/or dobutamine, arrhythmia, intra-abdominal hypertension and patients younger than 18 years.

Treatment and study plan

vasoplegic syndrome

Other

Patients with vasoplegic syndrome for whom the intensive care physician planned to decrease the norepinephrine dosage were included. Hemodynamic and uncalibrated pulse contour analysis (Volume view, FloTrac, Edwards Lifescience, Irvine) values were obtained before and after decreasing the norepineprhine dosage. Responders were defined by a >10% decrease in mean arterial pressure (MAP).

Primary outcomes

  1. Dynamic arterial elastance (Eadyn) defined as the ratio of PPV/SVV calculated from uncalibrated pulse contour analysis

    Time frame: 60 minutes

Sponsors and collaborators

Lead sponsor

Centre Hospitalier Universitaire, Amiens

Other

Registry information

Official study title

Dynamic Arterial Elastance Measured by Uncalibrated Pulse Contour Analysis Predicts Arterial Pressure Response to a Decrease in Norepinephrine (VESA) Dynamic Arterial Elastance Measured by Uncalibrated Pulse Contour Analysis

Acronym: VESA

Important dates

Study start
2016
Primary completion
2017
Study completion
2017
First posted
Mar 7, 2018
Registry last updated
Jun 25, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.