The purpose of this study is to evaluate real-time gap detection using EPD D700 dielectric sensing compared with customary electrical isolation tests and Adenosine infusion at the end of the procedure. Furthermore, safety, usability and clinical applicability of the system for guided AF ablation will be confirmed.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Interventional
Not applicable
Novosibirsk, 630055, Russia
Prospective, single-center, non-randomized, non-blinded, open label, and single arm study.
All procedures will be performed under CARTO-3 guidance for the treatment of atrial fibrillation (AF). The EPD D700 system will be used in-tandem, to record pre-, during and immediate post-ablation tissue characteristics and compute likelihood of lesion transmurality and permanency. Additionally, D700 system safety, feasibility, usability and clinical applicability will be documented.
The entire procedure will be conducted as customary, using standard and approved off-the-shelf equipment (body surface electrodes, diagnostic and irrigated ablation catheters, RF generator and recording system), in a completely clinically independent manner from the EPD D700 system. The physician will neither use nor rely on any of the D700 system output for clinical decision making and will be blinded to the D700 lesion assessment forecasts. After 30 days following the initial procedure, a repeated procedure will be performed for gap detection and its results will be correlated with the D700 predictions.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Atrial Fibrillation Ablation Procedure
Time frame: 30 days
ETA Reading at Index Procedure vs. Actual Gaps at 1-month Restudy. All patients underwent PVI at index procedure. The physicians were blinded to the D700 (KODEX-EPD) ETA function pairwise real-time lesion assessment readings.
All patients were restudied at 1-mont, and ETA reading, which is the number of gaps as predicted by the system, were compared to the actual gaps as validated in the second procedure after one month.
Time frame: 30 days
ETA Reading at Index Procedure vs. Actual Gaps at 1-month Restudy
EPD Solutions, A Philips Company
Industry
Acronym: DURABLE-I
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05820295
Arrhythmias, Cardiac, Atrial Fibrillation
New York, United States
View Trial DetailsNCT05993897
Arrhythmias, Cardiac, Atrial Fibrillation
Aswān, Aswan Governorate, Egypt
View Trial DetailsNCT05357690
Arrhythmias, Cardiac, Atrial Fibrillation
Rochester, Minnesota, United States
View Trial DetailsNCT05164718
Arrhythmias, Cardiac, Atrial Fibrillation
Drammen, Norway
View Trial Details