Skip to main content
OpenTrials
Completed

NCT Number: NCT01760200

Drug Eluting Balloon Versus Drug Eluting Stent in PCI

Drug eluting balloons (DEB) have been developed to overcome the limitations of drug eluting stent (DES), but clinical results of different studies about DEB are not consistent.

Thus, we planned a meta-analysis to compare outcomes of DEB and DES in coronary artery disease (CAD).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–89 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Azienda Ospedaliero Universitaria Maggiore della Carita

Novara, Piedmont, 28100, Italy

About this study

Drug eluting balloons (DEB) have been developed to overcome the limitations of drug eluting stent (DES), but clinical results of different studies about DEB are not consistent. Thus, we performed a meta-analysis to compare outcomes of DEB and DES in coronary artery disease (CAD).

The meta-analysis was performed according to the recommended methods [14-15]. A systematic search for eligible studies involved MEDLINE, CENTRAL, Embase, Highwire Press, Scopus and Google Scholar databases and was conducted without language restriction by two independent investigators (A.L. and A.R.), using the following keywords: "drug", "eluting" "balloon(s)", "DEB", "coronary", "angioplasty". Divergences were resolved by consensus. Endnote software v. 10 was used to build up libraries of results that were combined after erasing duplicates. The references of retrieved studies were searched manually for additional trials, and efforts to contact authors were performed to obtain further study details or additional references. The search is updated to December 2012.

Selection criteria: citations were screened at title and abstract level and retrieved as full reports.

  • Inclusion criteria were: 1) randomized studies or cohort studies reporting a comparison between a DEB treated group and a DES treated group; 2) availability of reports of late lumen loss (LLL) and/or overall death and/or myocardial infarction (MI) and/or stent thrombosis (ST) and/or target lesion revascularization (TLR).
  • Exclusion criteria were: 1) duplicate reporting (in which case the manuscript reporting the largest sample or the longest follow-up was selected), 2) follow up of at least 6 months; 3) studies presenting composite major adverse cardiac events (MACE) without mentioning individual end points. Data were abstracted on pre-specified forms by 2 unblinded reviewers; divergences were resolved by consensus.

Internal validity : the present meta-analysis was performed according to the Guidelines for randomized controlled trials of the Cochrane Collaboration and for non randomized studies in compliance with the Guidelines of the MOOSE group. Quality of included studies was appraised by 2 unblinded investigators. The risk of selection, performance, detection, and attrition bias (expressed as low risk of bias [A], moderate risk of bias [B], high risk of bias [C], or incomplete reporting leading to inability to ensure the underlying risk of bias [D]) were evaluated separately, as recommended. Non-randomized studies were evaluated using the Newcastle-Ottawa Scale a validated technique in assessing the quality of non-randomized studies.

Data analysis and synthesis: Odds ratios (ORs) were computed from individual studies and pooled according to a fixed effect (e.g. inverse variance weighting) or random effect model in case of statistical heterogeneity. Two separate subgroup analysis were pre-specified: 1) exclusion of studies with small vessel and bifurcation PCI; 2) exclusion of non-randomized studies 3) exclusion of studies in which DEBs were not used together with BMS deployment.

Results will be presented as overall meta-analysis and subgroups meta-analyses for DEB vs DES comparisons. Outcomes appraised were in-stent LLL, overall death, MI, ST and TLR. We used the Mantel-Haenszel method for combining ORs, a validated method to pool the data in a meta-analysis of binary outcomes. For the in-stent LLL outcome, the mean difference of 6-month LLL compared with baseline was used and the overall weighted mean difference (WMD) was built with the inverse variance method. Heterogeneity was assessed by Cochran's Q test, with 2-tailed p=0.1. Statistical inconsistency test (I2) was also employed to overcome the low statistical power of Cochran's Q test. The potential publication bias was examined by constructing a "funnel plot", in which sample size was plotted against odds ratios. In addition, a mathematical estimate of the asymmetry of this plot was provided by a linear regression approach. Asymmetry was considered to be present if the intercept of the regression line did deviate significantly from zero. To explore and mitigate heterogeneity, pre-specified covariates (prevalence of diabetes in the study population and reference coronary vessel diameter) as potential confounders were considered in the meta-regression analysis.

Pooling of data, subgroup analyses and publication bias tests were performed with Review Manager 5.1 (The Nordic Cochrane Center, Købehvn, Denmark) and StatsDirect v 2.7.8 (StatsDirect Ltd, Cheshire WA, UK). Meta-regression analyses were builded with Comprehensive Meta-analysis Version 2 (Biostat, Englewood, New Jersey, United States).

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • randomized studies or cohort studies reporting a comparison between a DEB treated group and a DES treated group
  • availability of reports of late lumen loss (LLL) and/or overall death and/or myocardial infarction (MI) and/or stent thrombosis (ST) and/or target lesion revascularization (TLR).

Exclusion criteria

  • duplicate reporting (in which case the manuscript reporting the largest sample or the longest follow-up was selected)
  • follow up of at least 1 year
  • studies presenting composite major adverse cardiac events (MACE) without mentioning individual end points.

Treatment and study plan

Primary outcomes

  1. Overall mortality

    Time frame: 1 year

    mortality rate from all cause

Secondary outcomes

  1. Myocardial infarction rates

    Time frame: 1 year

    Myocardial infarction rates

  2. Target vessel revascularization

    Time frame: 1 year

    symptoms or ischemia driven new revascularization of the coronary artery already treated with DEB at baseline

Sponsors and collaborators

Lead sponsor

Azienda Ospedaliero Universitaria Maggiore della Carita

Other

Registry information

Official study title

Drug Eluting Balloon Versus Drug Eluting Stent in Coronary Artery Disease PCI: Insights From a Meta-analysis of 1462 Patients

Important dates

Study start
2012
Primary completion
2012
Study completion
2012
First posted
Jan 4, 2013
Registry last updated
Jan 4, 2013

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.