TAVR for BAV Using Down Sizing with the Evolut Pro platform
ProcedureDown sizing strategy in Type 0 bicuspid aortic stenosis patients undergoing transcatheter aortic valve replacement with self-expanding valves
Other names: Down Sizing Strategy
NCT Number: NCT05511792
To compare down sizing strategy versus annular sizing strategy technique (control group) in Type 0 bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR) with self-expanding valves (SEVs): a randomized superiority trial
Interested in participating?
Request Info60 year and older
All sexes
Interventional
Not applicable
Fujian Provincial Hospital, Affiliated to Fuzhou University, Fuzhou, Fujian, China
Transcatheter aortic valve replacement (TAVR) has emerged as a favorable alternative for severe symptomatic aortic stenosis (AS) patients of all surgical risk profiles. Patients with bicuspid aortic valve (BAV) underwent TAVR had similar 30-day mortality as well as stroke and new pacemaker implantation rates compared to tricuspid aortic valve (TAV) subjects, but carried higher risk of moderate/severe perivalvular leakage (PVL), conversion to surgery and device failure. Clinical experience in China suggests BAV and heavy calcium burden are more common among TAVR candidates than US/EU cohorts.
Morphological characteristics at supra-annular structure (from annulus to the level of sinotubular junction) are quite complex in BAV, especially concomitant with heavily calcified leaflets. From our previous single center clinical practice, "waist sign" above the annulus during balloon aortic valvuloplasty in TAVR was often observed in patients with bicuspid AS, suggesting that supra-annular structures are the most constrained portion of BAV anatomy where the prosthesis anchors and seals. Therefore, we developed a balloon based supra-annular sizing strategy for self-expanding valves implantation in BAV and the device failure rate as well as pacemaker implantation rates were relatively low as shown in previous cohort study. Several other studies have also achieved successful outcomes associated with device "down sizing" (using a device smaller than that recommended by annular sizing).
The aim of this study is to compare "down sizing"strategy (experimental group) versus annular sizing strategy (control group) in BAV patients undergoing TAVR with self-expanding valves.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Down sizing strategy in Type 0 bicuspid aortic stenosis patients undergoing transcatheter aortic valve replacement with self-expanding valves
Other names: Down Sizing Strategy
Traditional sizing strategy in Type 0 bicuspid aortic stenosis patients undergoing transcatheter aortic valve replacement with self-expanding valves
Other names: Standard Sizing Strategy
Time frame: 1 month after index procedure
Composite endpoint of Device Success (VARC-3), Free of pacemaker implantation, and Free of new onset complete left bundle branch block at 1 month
Time frame: 1 month after index procedure
New onset complete left bundle branch block with QRS ≥120ms at 1 month
Time frame: 1 month after index procedure
Permanent pacemaker implantation within one month
Time frame: 1 month after index procedure
Device success per VARC-3 definition
Time frame: 1 month after index procedure
More than (≥) moderate regurgitation on echocardiography at 1month
Contact information is provided by the study sponsor or research team.
Second Affiliated Hospital, School of Medicine, Zhejiang University
Other
Transcatheter Aortic Valve Replacement For Patients With Bicuspid Aortic Stenosis (Type 0) Using Down Sizing Strategy Compared With Standard Sizing Strategy (HANGZHOU Solution): A Prospective, Multicenter, Randomized Controlled Trial
Acronym: TAILOR-TAVR
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04722796
Aortic Stenosis, Aortic Stenosis With Bicuspid Valve
Bengbu, Anhui, China
View Trial DetailsNCT05844969
Aortic Stenosis With Bicuspid Valve
Cambridge, United Kingdom
View Trial Details