Skip to main content
OpenTrials
Completed

NCT Number: NCT05664555

Dose Optimization for Safe and Efficient Fluorescein Angiography (DOSE Study)

This study aims to compare the efficacy and safety of fluorescein angiography using 1mL versus 3mL of 10% fluorescein dye.

Completed

Looking for future studies?

Notify Me

Key information

Age range

19 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

Seoul National University Bundang Hospital

Seongnam-si, Gyeonggi-do, 13620, South Korea

About this study

The investigators will recruit patients who need fluorescein angiography for their retinal diseases.

The investigators will collect data on image quality and complications.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients who required an fluorescein angiography for their retinal diseases (eg. diabetic retinopathy, retinal vein occlusion, etc.)

Exclusion criteria

  • media opacity (corneal opacity, vitreous hemorrhage grade 2 or more, cataract LOCS III grade 3 or more)
  • known history of adverse reactions to fluorescein
  • dilated pupil diameter less than 5 mm

Treatment and study plan

fluorescein sodium

Drug

Patients will receive Fluorescein Sodium 3mL (300mg) or 1mL (100mg) intravenously prior to fluorescein angiography.

Primary outcomes

  1. Subjective image quality from 3 experts

    Time frame: One month

    Images from two dose groups will be compared in terms of central and peripheral image quality. Three retinal experts were masked to the fluorescein dose the patients had received. Each expert graded patients' fluorescein angiography images on a scale of 1 to 5 (1:very poor, 2: poor, 3: average, 4: better than average, 5: excellent) with respect to the subjective quality of the image and aid of making a diagnosis. The mean value of the image quality score will be compared between the two dose groups.

Secondary outcomes

  1. Objective vessel intensity

    Time frame: One month

    Mean vascular pixel intensity was quantitatively measured using ImageJ (version 1.54f, National Institutes of Health). The 8-bit grayscale image was imported into imageJ and processed with a top-hat filter to suppress the background noise. This UWFA image was divided via a customized grid, consisting of 2 rings centered on the fovea. The mean vascular pixel intensity in each of these zones was then automatically measured using imageJ software.

  2. Complication

    Time frame: immediately after the test

    frequency of complication of fluorescein angiography will be compared between two groups

Sponsors and collaborators

Lead sponsor

Seoul National University Bundang Hospital

Other

Registry information

Official study title

Low Dose Fluorescein Angiography Comparing 1mL and 3mL of 10% Fluorescein: A Randomized Controlled Trial

Acronym: DOSE

Important dates

Study start
2023
Primary completion
2024
Study completion
2024
First posted
Dec 23, 2022
Registry last updated
Apr 17, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.