NCT Number: NCT03160456

Domiciliary Transcutaneous Electrical Stimulation in Obstructive Sleep Apnoea

The aim of this study is to assess the efficacy of transcutaneous electrical stimulation of the pharyngeal dilator muscles in patients with obstructive sleep apnoea in the community compared to usual care, and follow the patients for three months, as well as to assess compliance of non-invasive electrical stimulation of the upper airway dilator muscles in obstructive sleep apnoea patients over time and evaluate the control of symptoms and improvement in quality of life.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–85 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Guy's & St Thomas' NHS Foundation Trust

London, SE1 7EH, United Kingdom

About this study

Obstructive sleep apnoea is highly prevalent, with the obesity epidemic increasing the problem. The best treatment for uncomplicated and moderate-severe OSA remains CPAP therapy. However, long-term adherence to treatment with CPAP is poor and there are few alternatives. Electrical stimulation of the dilator muscles of the upper airway has been shown to reduce nocturnal apnoeas significantly using an invasive approach, hypoglossal nerve stimulation, as well as by non-invasive transcutaneous stimulation. Although non-invasive transcutaneous stimulation may not be as effective as CPAP therapy in many OSA patients it could be an important option to treat some of the large number of patients who fail CPAP and might also be of use in those whose OSA is not judged sufficiently severe to warrant CPAP.

The investigators propose a study to use a transcutaneous electrical stimulation device in selected patients with OSA who do not tolerate CPAP therapy following assessment of the upper airway. Participants will undergo a baseline sleep study (polysomnography/home-based respiratory polygraphy). Following minimisation for gender (male/female) and OSA severity (mild/moderate-severe) they will be randomised into active treatment arm (transcutaneous electrical stimulation) or usual care (ongoing CPAP therapy). Patients will be treated over a period of 3-months in the community, re-assessed (including polysomnography/home-based respiratory polygraphy) and the results will be compared against usual care, ongoing CPAP therapy. This study will help to prepare a definitive multi-centre randomized controlled trial using the non-invasive method of upper airway stimulation in OSA.

The primary aim of this study is to assess efficacy and generate an accurate sample size estimation, test the subjective willingness of patients to use and objectively determined compliance with the treatment over a long period, as well as to specify the drop-out rate. The improvement in sleep apnoea will be the primary outcome measures. The symptomatic response, feasibility of the method, including compliance, comfort, adverse events, will be the secondary outcome measure. An ad-hoc analysis will be performed in the responder group (improvement in the apnoea-hypopnea index (AHI) by >50% from baseline OR improvement in the 4% oxygen-desaturation index (ODI) >25% from baseline OR AHI/4%ODI <5/hour at follow up).

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • mild-moderate OSA (AHI 5-35/hour)
  • difficulties with or failed CPAP and/or withdrawn from standard care (CPAP <4hours/night)
  • Body mass index (BMI) 18.5-32 kg/m2
  • No significant anatomical obstruction in the upper airway (e.g. normal sized tonsils).

Exclusion criteria

  • No OSA (AHI <5/h)
  • Severe obstructive sleep apnoea (AHI>35/hour)
  • Exclusively postural sleep apnoea
  • isolated Rapid-Eye-Movement (REM) sleep associated OSA
  • Cachexia (BMI <18.5 kg/m2)
  • Obesity (BMI >32 kg/m2)
  • Hypercapnic respiratory failure (pCO2>6.5 kPa)
  • Features of obesity hypoventilation syndrome (elevated bicarbonate, HCO3- >28mmol/L).
  • enlarged tonsils (size 3-4)
  • polyps and adenoids
  • neuromuscular disease
  • hypoglossal nerve palsy
  • abnormal pulmonary function tests
  • severe pulmonary hypertension
  • valvular heart disease
  • heart failure (New York Heart Association, NYHA III-IV)
  • myocardial infarction and significant cardiac arrhythmias
  • uncontrolled hypertension
  • active psychiatric disease
  • co-existing non-respiratory sleep disorder
  • significant metal implants or cardiac/other pacemakers.
  • facial hair that affects the correct placement of the hydrogel patch
  • endoscopically identified contraindication to upper airway stimulation (multi-level obstruction)

These criteria are consistent with our experience from previous trials using transcutaneous electrical stimulation in OSA and likely to identify potential responders; these criteria are also similar to those from trials using hypoglossal nerve stimulation.

Treatment and study plan

transcutaneous electrical stimulation

Device

The device needs to be started by pressing the 'on' button. Once the device is turned on the current intensity can be increased by pushing the '+' button and lowered by pushing the '-' button. When a comfortable skin sensation is felt the patients should press the '-' button once more. At that time the device stimulates with a low current which is not felt but provides a neuromuscular tone to the muscles whilst asleep. The device is kept on all night and in the morning taken off with the hydrogel and disconnected. Once disconnected it should be turned off by pressing the 'off' button.

Other names: TESLA home

Continuous Positive Airway Pressure

Device

CPAP will be applied according to usual clinical care, the follow up will be organised in the same way as the active intervention group.

Other names: CPAP (usual care)

Primary outcomes

  1. Apnoea Hypopnoea Index

    Time frame: 3 months

    AHI

Secondary outcomes

  1. Epworth Sleepiness Scale

    Time frame: 3 months

    ESS (0-24 points)

  2. Oxygen Desaturation Index

    Time frame: 3 months

    4%ODI (x hour-1)

  3. Usage of treatment

    Time frame: 3 months

    Usage per night (average hours)

  4. Compliance with treatment

    Time frame: 3 months

    Percentage of nights used (%)

  5. Acceptance of device

    Time frame: 3 months

    Visual analogue scale (points, 0-10)

  6. Sleep related quality of life

    Time frame: 3 months

    FOSQ

  7. Snoring

    Time frame: 3 months

    Percentage of the night (%)

  8. Genioglossus contraction

    Time frame: 3 months

    Ultrasound (thickness, mm)

  9. General quality of life

    Time frame: 3 months

    EQ-5D

  10. Anatomy of upper airway

    Time frame: at baseline

    Endoscopically identified diameter (mm)

Other outcomes

  1. Responder rate

    Time frame: 3 months

    Reduction in AHI by more than 50% and / or to below 5/hour

Sponsors and collaborators

Lead sponsor

Guy's and St Thomas' NHS Foundation Trust

Other

Collaborators

  • King's College Hospital NHS Trust
  • King's College London
  • Royal Brompton & Harefield NHS Foundation Trust

Registry information

Official study title

Randomised Controlled Trial of Domiciliary Transcutaneous Electrical Stimulation in Obstructive Sleep Apnoea

Acronym: TESLA-home

Important dates

Study start
2018
Primary completion
2023
Study completion
2023
First posted
May 19, 2017
Registry last updated
May 9, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.