Mount-Sinai Roosevelt hospital
New York, 10019, United States
NCT Number: NCT02207972
The investigators believe that ultrasound guided CSE technique will accurately place the epidural needle in the midline position compared to epidural needle placement via palpation of anatomical landmarks. This will result in positive CSF in the spinal needle, correct placement of the catheter, and adequate symmetrical labor analgesia/anesthesia.
Looking for future studies?
Notify Me18 year–48 year
Female
Interventional
Not applicable
New York, 10019, United States
Epidurals provide superior labor analgesia and anesthesia. Unfortunately, failure of epidural anesthesia and analgesia is a frequent clinical problem. In a heterogeneous cohort of 2,140 surgical patients, a failure rate of 27% for lumbar epidural was described. However, the definition of a failed epidural is broad. Different definitions include insufficient analgesia to catheter dislodgement to conversion to general anesthesia. Epidural analgesia failures may result from technical difficulties, insufficiencies or overdosing of local anesthetics, epidural septum or midline adhesions, and placement of the epidural catheter through an intervertebral foramen or into the anterior epidural space. In an imaging study of failed epidurals, incorrect catheter placement accounted for half of the failures, while the remaining patients experienced suboptimal analgesia through a correctly positioned catheter.
The incidence of overall failure was lower in patients receiving combined spinal-epidural (CSE) catheters versus epidural analgesia. In one study, the CSE technique provided decreased failure rates for labor analgesia and comparable or decreased failure rates for surgical anesthesia, when compared with reported failure rates for epidural anesthesia. It is believed that positive CSF flow in the spinal needle confirms correct epidural needle placement in the epidural space and also confirms the epidural needle to be in the midline position. Placement of the epidural needle in the midline position will minimize the incorrect placement of the catheter to one side, providing a symmetrical analgesia versus unilateral analgesia.
However, the practice of CSE and epidural catheter placement relies on the palpation of anatomical landmarks that are not always easy to feel. Therefore, the epidural needle maybe placed "off midline" despite positive loss of resistance (LOR) that causes negative CSF flow in the spinal needle and an incorrectly placed catheter. As a result, the incorrect catheter placement will result in a "failed" or suboptimal epidural analgesia.
Ultrasound has recently been utilized to facilitate lumbar epidurals and spinals. The US imaging of the lumbar spine in different scanning planes facilitates the identification of the landmarks necessary for appropriate epidural space location in pregnant patients. There are two acoustic windows that are effective for lumbar spine sonographic assessment: one seen on the transverse approach, and the other seen on the longitudinal paramedian approach. The ultrasound single-screen method using the transverse approach of the lumbar spine provides reliable information regarding the landmarks required for labor epidurals. The correct interspace and midline position are identified for correct placement of the CSE analgesia.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The ultrasound imaging of the lumbar spine in different scanning planes facilitates the identification of the landmarks necessary for appropriate epidural space location in pregnant patients. There are two acoustic windows that are effective for lumbar spine sonographic assessment: one seen on the transverse approach, and the other seen on the longitudinal paramedian approach. The ultrasound single-screen method using the transverse approach of the lumbar spine provides reliable information regarding the landmarks required for labor epidurals. The correct interspace and midline position are identified for correct placement of the CSE analgesia.
Palpation of anatomical landmarks is used for placement of labor analgesia
Time frame: 2 hours
Number of ultrasound guided CSE technique accurately placed epidural needle in the midline position
Time frame: Immediate
The number of participants who had first attempt success to locate the epidural space and midline position
Time frame: immediate
the number of participants with successes without any readjustment of the angle in the space
St. Luke's-Roosevelt Hospital Center
Other
Does Ultrasound-guided CSE Technique Improve Midline Placement of Epidural Needle With Positive CSF Flow, Thereby Facilitating Correct Placement of the Catheter Compared to Catheter Placement Using Palpation of Anatomical Landmarks?
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07725549
Birth Weight, Body Weight
Purwodadi Grobogan, Central Java, Indonesia
View Trial DetailsNCT02447159
Behavior, Blood-Borne Infections
Eket, Akwa Ibom State, Nigeria
View Trial DetailsNCT07072507
Birth, Birth Memory
Bursa, Turkey (Türkiye)
View Trial DetailsNCT04446611
Acquired Immunodeficiency Syndrome, Antenatal Care
East London, Eastern Cape, South Africa
View Trial Details