Department of Neurology, University of Regensburg
Regensburg, Bavaria, 93053, Germany
NCT Number: NCT04771858
The aim of this study is the development of novel telemedical examination methods based on sensor-based gait analysis in patients with multiple sclerosis (MS). In a first step, the basic technical feasibility of measuring gait parameters in MS patients under standardized conditions in the clinic and in the home environment of the study participants will be investigated.
In a subsequent two-week study phase, gait parameters (real-life monitoring) and standardized gait tests will be continuously recorded in the home environment of the study participants. The comparability of the collected gait parameters from standardized gait tests and real-life monitoring to clinical scales (e.g. EDSS) will investigate the medical applicability of gait analysis as a target parameter in MS patients.
New algorithms for detecting indication-specific gait patterns from gait analysis in patients' daily lives and their possible changes over time (progression) will be explored and implemented into the study system. In addition, a patient app annotates the standardized gait tests and collects questionnaire-based data from the study participants during real-life monitoring. Via a study tablet, the data of the gait analysis and the patient app are transmitted to a study platform (Digital Patient Manager). The clinical assessment data (neurological examination, questionnaires) can be entered via a web front-end of the study platform and assigned to the patient via a pseudonym.
A further aim of this study is to validate the technology used for its applicability in the home environment. By means of structured interviews after the study phase, the study participants will be asked about compliance and adherence.
The following scientific questions will be investigated in this project:
(a) Is gait analysis a feasible and meaningful target parameter for MS centers? b) Are gait parameters from real-life monitoring suitable biomarkers for the detection of MS symptoms? c) Can gait parameters from standardized gait tests be compared with different testing environments (clinic / home environment)? d) How do gait parameters from standardized gait tests differ from gait data from real-life monitoring? e) How is the telemedical application for the collection of gait parameters evaluated by the patients? f) Can disease progression be detected using sensor-based gait parameters from the home environment?
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Regensburg, Bavaria, 93053, Germany
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: day 1 to day 14
Number of sensor-detected gait cycles (one gait cycle are two steps) per patient per day
Time frame: day 1 to day 14
Percentage of sensor wear time per patient per day - range from 0 hours (0%) to 6 hours (100%)
Time frame: day 1 to day 14
Percentage of days with sensor data recorded per patient - range from 0 days (0%) to 14 days (100%)
Time frame: day 14 (closeout visit)
SUS score per patient - range from 0 to 100 score points (Higher scores mean a better outcome.)
Time frame: day 1
Difference in time, measured in seconds, of 25FWT performed at home and performed at clinic
Time frame: day 14
Difference in time, measured in seconds, of 25FWT performed at home and performed in clinic
Time frame: day 1
Difference in gait parameters (gait length in cm, speed in m/s, contact angle in degree, swing-through phase in percent, standing phase in percent, lateral swing in cm, toe clearance in cm, lifting angle of toes in cm, impact intensity in g, variability of these parameters and symmetry between left and right foot) during 25FWT performed at home versus 25FWT performed at clinic
Time frame: day 14
Difference in gait parameters (gait length in cm, speed in m/s, contact angle in degree, swing-through phase in percent, standing phase in percent, lateral swing in cm, toe clearance in cm, lifting angle of toes in cm, impact intensity in g, variability of these parameters and symmetry between left and right foot) during 25FWT performed at home versus 25FWT performed at clinic
Time frame: day 1 and day 14
Correlation of change of EDSS (range from 0.0 to 10.0, Lower scores mean a better outcome.) and change of time to execute 25FWT in seconds performed at home
Time frame: day 1 and day 14
Correlation of change of EDSS (range from 0.0 to 10.0, Lower scores mean a better outcome.) and change of time to execute 25FWT in seconds performed at clinic
Medical Valley Digital Health Application Center GmbH
Industry
MSgoesHome - Digital Gait Analysis in the Home Environment of Patients With Multiple Sclerosis
Acronym: MSgoesHome
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03963375
Autoimmune Diseases, Autoimmune Diseases of the Nervous System
St Louis, Missouri, United States
View Trial DetailsNCT02511028
Autoimmune Diseases, Autoimmune Diseases of the Nervous System
Bethesda, Maryland, United States
View Trial DetailsNCT07175792
Autoimmune Diseases, Autoimmune Diseases of the Nervous System
Diepenbeek, Belgium
View Trial DetailsNCT07726667
Autoimmune Diseases, Autoimmune Diseases of the Nervous System
Gaziantep, Gaz, Turkey (Türkiye)
View Trial Details