Ospedale Regionale di Locarno
Locarno, Canton Ticino, 6928, Switzerland
NCT Number: NCT01898234
Background:
High- and low-flux dialysis membranes made of different materials may correlate with various hemodynamic tolerance profiles. This study aims to investigate hemodynamic response and incidence of hypotensive episodes by comparing some of the most commonly used high- and low-flux dialyzers.
Methodology:
The study was designed as an open label, randomized, cross-over investigation, including 25 patients undergoing chronic hemodialysis. Four polysulfone dialyzers of 1.8 m2, A (Revaclear, Gambro), B (Helixone high flux, Fresenius), C (Xevonta, BBraun) and D (Helixone low flux, Fresenius), were compared with each other. The hemodynamic profile was assessed with a non-invasive technique and patients were asked to provide tolerance feedback through a questionnaire.
Looking for future studies?
Notify Me18 year–95 year
All sexes
Interventional
Not applicable
Locarno, Canton Ticino, 6928, Switzerland
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Four polysulfone dialyzers of 1.8 m2, A (Revaclear, Gambro), B (Helixone high flux, Fresenius), C (Xevonta, BBraun) and D (Helixone low flux, Fresenius), were compared with each other
Other names: -Revaclear, Gambro 1.8 m2
Four polysulfone dialyzers of 1.8 m2, A (Revaclear, Gambro), B (Helixone high flux, Fresenius), C (Xevonta, BBraun) and D (Helixone low flux, Fresenius), were compared with each other
Other names: Helixone high flux, Fresenius 1.8 m2
Four polysulfone dialyzers of 1.8 m2, A (Revaclear, Gambro), B (Helixone high flux, Fresenius), C (Xevonta, BBraun) and D (Helixone low flux, Fresenius), were compared with each other
Other names: Xevonta, BBraun 1.8 m2
Four polysulfone dialyzers of 1.8 m2, A (Revaclear, Gambro), B (Helixone high flux, Fresenius), C (Xevonta, BBraun) and D (Helixone low flux, Fresenius), were compared with each other
Other names: Helixone low flux, Fresenius 1.8 m2
Time frame: 4 weeks
Time frame: 4 weeks
As to the assessment of subjective tolerance, we decided to administer the questionnaire designed by Cruz et al. [Cruz DN, Mahnensmith RL, Brickel HM, Perazella MA. Midodrine and cool dialysate are effective therapies for symptomatic intradialytic hypotension. Am. J. Kidney Dis. 1999 Mag;33(5):920-926] then modified by Teruel et al. [Teruel JL, Martins J, Merino JL, Fernández Lucas M, Rivera M, Marcén R, et al. Temperature of the dialysis bath and hemodialysis tolerance. Nefrología: PublicaciónOficial De La Sociedad Española Nefrologia. 2006;26(4):461-468] and to integrate it with a 1 to 10 numerical scale to assess patient well-being
Time frame: 4 weeks
Time frame: 4 weeks
Ospedale Regionale di Locarno
Other
Assessment of Subjective and Hemodynamic Tolerance of Different High- and Low-flux Dialysis Membranes in Patients Undergoing Chronic Intermittent Hemodialysis: a Randomized Controlled Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.