Skip to main content
OpenTrials
Completed

NCT Number: NCT04006964

Diagnostic Accuracy Of Forced Oscillation Technique To Detect Lung Function Anomalies

The diagnosis of a lung function anomaly requires the evaluation of pulmonary function by spirometry. However, some patients (e.g. children, elderly, or diseased individuals) may have difficulty performing the related forced maximal respiratory maneuver correctly. Forced Oscillation Technique (FOT) measures lung impedance during tidal breathing, requiring minimal patient cooperation. The purpose of this study is to establish the diagnostic accuracy of FOT parameters alone or in combination with lung volumes in detecting lung function anomalies as compared with spirometry and with the diagnosis made by the physician.

Completed

Looking for future studies?

Notify Me

Key information

Age range

3 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Azienda Ospedaliero, Universitaria Meyer, Florence, FI, Italy

Loading trial locations.

About this study

Purpose and Rationale The diagnosis of a lung function anomaly requires the evaluation of pulmonary function by spirometry. However, some patients (e.g. children, elderly, or diseased individuals) may have difficulty performing the related forced maximal respiratory maneuver correctly. FOT measures lung impedance during tidal breathing, requiring minimal patient cooperation. The within-breath calculation of impedance allows separating the contribution of inspiration and expiration to the measured parameters. The purpose of this study is to establish the diagnostic accuracy of FOT parameters alone or in combination with lung volumes in detecting lung function anomalies as compared with spirometry and with the diagnosis made by the physician.

Objectives Primary: To compare the diagnostic accuracy of FOT with spirometry to detect a lung function anomaly (i.e. an obstructive and/or restrictive respiratory disease).

Secondary: To compare the diagnostic accuracy of FOT with the final diagnosis made by the physician (i.e. the diagnosis based on current guidelines) to detect a lung function anomaly (i.e. an obstructive and/or restrictive respiratory disease).

Study Design This will be a multi-center prospective study of consecutive subjects attending the pulmonary function test laboratory for pulmonary function tests (PFT) or randomly taken from the clinical site's records among those with symptoms with two separate study phases, an Identification Phase and a Validation Phase. Subjects will undergo the same study procedures in both phases. After signing the Informed Consent, a medical history will be obtained, a physical examination performed, and PFT (FOT, spirometry and, if required by the physician to reach a final diagnosis, additional lung function measurements) will be performed.

Identification Phase: Subject data will be used to identify two separate rules based on abnormal lung volumes and impedance (FOT) parameters that will maximize the accuracy in identifying a lung function anomaly. For the primary objective, the reference test for the determination of such lung anomaly will be spirometry. For the secondary objective, the reference test for the determination of the presence of a lung function anomaly will be the final diagnosis made by the physician.

Validation Phase: A separate and independent dataset of subjects will be used to test the accuracy of the rules identified from analysis of the Identification Phase in detecting a lung function anomaly.

Study Duration Subject participation will be completed in 1 day. Study duration is expected to be 7 months

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • All subjects ≥3 years old attending the pulmonary function laboratory with an order for PFT or
  • Subjects ≥3 years old randomly chosen from a database of subjects having respiratory symptoms at the time of inclusion into the database.

Exclusion criteria

  • Subjects unable to provide written Informed Consent (or not provided by the participant's parent/guardian) and Assent Form (where applicable).

Treatment and study plan

Resmon PRO FULL v2

Device

Measurement of lung impedance by the Forced Oscillation Technique

Primary outcomes

  1. Decision rule that maximises sensitivity and specificity as compared with spirometry

    Time frame: 1 day

    This will be a rule to detect lung anomalies as compared with spirometry that will be identified and validated in two separate populations

Secondary outcomes

  1. Decision rule that maximises sensitivity and specificity as compared with physician's diagnosis

    Time frame: 1 day

    This will be a rule to detect lung anomalies as compared with physician's final diagnosis that will be identified and validated in two separate populations

Sponsors and collaborators

Lead sponsor

Restech Srl

Industry

Collaborators

  • MGC Diagnostics

Registry information

Important dates

Study start
2018
Primary completion
2022
Study completion
2022
First posted
Jul 5, 2019
Registry last updated
Nov 3, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.