National Heart Centre Singapore
Singapore, 169609
NCT Number: NCT02790918
In this study, study team aim to i) evaluate the accuracy of 3D IVS curvedness for prediction of RV systolic pressure (RVSP), mean pulmonary artery pressure (mPAP) and pulmonary vascular resistance (PVR) with RHC; ii) evaluate the usefulness of 3D IVS curvedness for predicting the response to vasodilator challenge with RHC, in patients clinically suspected or known to have primary PH.
Looking for future studies?
Notify Me16 year–99 year
All sexes
Observational
Singapore, 169609
Right heart catheterization (RHC) is the current reference standard for diagnosing PH (Galie et al 2009; McLaughlin et al 2009), according to ACCF/AHA expert consensus (McLaughlin et al 2009) and ESC/ERS guidelines (Galie et al 2009). Three hemodynamic measurements are essential from RHC: right ventricular systolic pressure (RVSP), mean pulmonary artery pressure (mPAP) and pulmonary vascular resistance (PVR). Further, patients with PH undergo RHC to assess clinical response to vasodilator challenge in order to guide therapy. It helps identify patients with better prognosis and patients who could potentially benefit from treatment with calcium channel blockers. A positive acute response is defined as a reduction of pulmonary artery pressure ≥10mmHg and ≤40mmHg. Although RHC plays a pivotal role in PH diagnosis, it is invasive and not without its own inherent risks (Hoeper et al 2006). For these reasons, development of a noninvasive alternative to RHC for diagnosis of PH is paramount.
Noninvasive diagnosis of PH and prediction of response to vasodilator challenge is clinically needed.
Several noninvasive methods for diagnosis of PH have been propounded, the most common being Doppler echocardiography. While routinely used to estimate pulmonary arterial pressure, Doppler measurement of tricuspid regurgitation jet peak velocity has inherent limitations: (i) the reliance on the visualization of the tricuspid regurgitant jet which is not always detectable, (ii) the fact that peak velocity of the jet may be difficult to measure in the presence of severe tricuspid regurgitation, and (iii) the need for adequate acoustic windows (Hinderliter et al 2003; Hachulla et al 2005). Furthermore, as recently emphasized in the ERS/ESC guideline (Galie et al 2009), estimation of mPAP or PVR must be an integral part of a complete cardiac echocardiographic examination.
It has long been recognized that systolic flattening and abnormal motion of the inter-ventricular septum (IVS), from either echocardiography (King et al 1983; Reisner et al 1994; Ricciardi et al 1999) or cine CMR images (Roeleveld et al 2005; Dellegrottaglie et al 2007; Alunni et al 2010), are signs of increased pulmonary arterial pressures. However, these studies are either qualitative or limited to 2D assessment, relying for analysis on subjective selection of the imaging plane and cardiac cycle phase. In the last 10 years, despite advances in biomedical engineering and computational approaches, no rigorous studies have been undertaken to study the relationship between quantitative 3D IVS shape and PH.
It is well documented that RV dysfunction and the 6-min walk test (6MWT) are associated with increased risk of mortality in PH (van Wolfersen 2007). Study team has recently developed a new method for assessment of RV function in terms of area strain, integrating radial, circumferential and longitudinal deformation (Zhong et al 2012). Therefore, we will also investigate the relationship between RV area strain and exercise capacity in PH.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Contraindication to MR examination:
Each patient will also receive 6MWT at cardiovascular rehabilitation and preventive cardiology laboratory. Besides the distance covered in meters or converted measure (such as feet) over 6 minutes, a portable metabolic system is used to measure oxygen uptake during exercise (VO2 testing) for each patient.
MRI uses interaction of the magnetic properties of body tissues with strong magnetic fields to create images; for about 1 hour. Several sets of images are needed. No injection of drug or dye will be used for this procedure.
Time frame: 1-Year
National Heart Centre Singapore
Other
Noninvasive Diagnosis of Pulmonary Hypertension Using Three-dimensional Interventricular Septal Curvedness From Cardiac Magnetic Resonance Images
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00011648
Anemia, Anemia, Hemolytic
Washington D.C., District of Columbia, United States
View Trial DetailsNCT00678821
Cardiovascular Diseases, Hypertension
Bethesda, Maryland, United States
View Trial DetailsNCT03629340
Cardiovascular Diseases, Heart Diseases
San Francisco, California, United States
View Trial DetailsNCT03626688
Cardiovascular Diseases, Connective Tissue Diseases
Birmingham, Alabama, United States
View Trial Details