This RCT aims to improve T1D care in East African children and young adults by testing the hypothesis that enabling patients to continuously monitor glucose levels with flash CGM technology will improve glucose time-in-range (glucose level 70-180 mg/dl). A second primary endpoint is to perform a cost analysis on flash glucose monitoring compared to 3x/day SMBG, to determine whether this technology is cost-effective in the setting of a less-resourced nation.
After a 2 week assessment with blinded CGM when a potential subject's ability to wear CGM is confirmed, subjects will be enrolled for 12 months in randomized, open label study, with a primary endpoint measurement at 6 months. All subjects will receive monthly diabetes self-management education.
For the first six months, months 1-6:
* Half of patients (n=90) will be randomized to an unblinded FreeStyle Libre 2 CGM.They and their care providers will be able to continuously see their CGM glucose levels to assist in insulin adjustment. * Half of patients (n=90) will be given sufficient test strips for 3x daily SMBG while wearing blinded CGM (control group). Neither they nor their care providers will be able to see their CGM glucose levels (the blinded CGM is simply for outcome measurement, not an intervention). As per usual clinical practice, only the SMBG glucose levels will be available to assist in insulin adjustment. * The change between baseline to 6 months in CGM-derived glucose percent time-in- range will be compared between groups (first primary study endpoint).
For the second six months, months 7-12:
* The control group will switch to unblinded CGM months 7-12 (their data months 7-12 months will be compared to their data months 1-6 as part of the primary endpoint assessment). * The patients who wore the unblinded CGM months 1-6 will continue for another 6 months to assess the impact of wearing the CGM for 12 continuous months (a secondary endpoint).
Once the clinical portion of the study is complete, study investigators who are health economists from the Uganda Ministry of Health will perform a costs analysis (second primary endpoint).
Interested in participating?
Request Info4 year–26 year
All sexes
Interventional
Phase 4
Minneapolis, Minnesota, 55455, United States
Location status: Recruiting
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The unblinded FreeStyle Libre 2 CGM will be placed every two weeks during months 0-12 for the CGM Cohort. Patients will be taught to insert the sensor themselves.
They will be given a 1 month supply at each monthly clinic visit and extra sensors in case a sensor falls out early. Patients will be given SMBG test strips to test capillary glucose for confirmation of any CGM glucose level <=60mg/dl. They will keep track of the number of times this is necessary. Patients will return used sensors at each clinic visit. The study team will upload the data to a study website. Patients and care providers will have access to unblinded sensor data for clinical use.
A glucose meter and sufficient teststrips for fingerpoke glucose monitoring 3x/day will be provided for months 1-6. This is standard-of-care in Uganda. Glucose meters will be downloaded monthly in clinic as per usual clinical practice.
DeviceBlinded CGM device: Libre Pro (blinded data collection device, not an intervention) The blinded FreeStyle Libre Pro CGM will be inserted at each monthly clinic visit to provide control data, months 0-6 for the Control Group. They will return all used sensors at each clinic visit. The study team will upload the data to a study website. Neither patients nor the local research teams will have access to the blinded sensor data for clinical use until the end of months 0-6 so as not to influence standard diabetes management. They will instead rely on SMBG values as per usual routine.
After the first 6 months they will receive Libre 2 CGM systems as described above for the intervention group.
Time frame: 6 months
The change in glucose Time-in-Range (percent time glucose levels are 70-180 mg/dl) from baseline to six months will be compared between patients wearing the unblinded CGM to those performing standard 3x/day SMBG.
Time frame: 1 year
Cost analysis on flash glucose monitoring compared to 3x/day SMBG, to determine whether this technology is cost effective in the setting of a low-resource nation.
Contact information is provided by the study sponsor or research team.
University of Minnesota
Other
Diabetes in African Youth: Improving Glucose Time-In-Range (DAYTime, Randomized Clinical Trial)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03528226
Autoimmune Diseases, Behavior
Lille, France
View Trial DetailsNCT05498974
Autoimmune Diseases, Diabetes
Lanzhou, Gansu, China
View Trial DetailsNCT03648918
Autoimmune Diseases, Diabetes Mellitus
Milwaukee, Wisconsin, United States
View Trial DetailsNCT05159856
Arterial Stiffness, Autoimmune Diseases
Herlev, Denmark
View Trial Details