Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06415721

Developing Functional Connectivity-Guided TMS for Alcohol Use Disorder

Alcohol Use Disorders are currently positioned as the third leading cause of preventable death in the United States, constituting a humanitarian crisis with substantial financial burden on society and medical facilities. While several pharmacological interventions exist, 60% of individuals who seek these treatments relapse to alcohol within 6 months. These high relapse rates are due in part to elevated brain response to alcohol cues in the environment. This study seeks to evaluate the efficacy of one session of functional Magnetic Resonance Imaging (fMRI) guided transcranial magnetic stimulation (TMS) as a strategy to reduce brain reactivity to alcohol cues.

Recruiting

Interested in participating?

Request Info

Key information

Age range

25 year–75 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

VA Palo Alto Health Care System

Palo Alto, California, 94304, United States

Location status: Recruiting

Location contact

Luzille Cowlah

CONTACT

[email protected]

4152799462

About this study

At least 60% of those with AUD will experience a major relapse period within 6 months of treatment, irrespective of the intervention (psychosocial and/or pharmacological) employed. Consequently, the high prevalence of AUD and relapse following treatment in Veterans is associated with substantial resource allocation and costs for the VA Health Care System. Current pharmacological and psychosocial interventions demonstrate only a moderate level of efficacy, which is reflected in the high rate of relapse in AUD. Transcanial Magnetic Stimulation (TMS) is a neurostimulation method that is at the forefront of innovative, non-invasive, and safe treatments for AUD, and other psychiatric disorders. To reduce the high rate of relapse in Veterans with AUD, it is necessary for interventions to more effectively address the associated neurobiological dysfunction. Non-invasive neuromodulation techniques are showing promise toward the aim of modifying specific and selective neural targets related to AUD and relapse. To date, TMS has been primarily delivered to the dorsolateral and medial prefrontal cortices as these regions are, on average, highly reactive to alcohol cues. On an individual basis, however, peak brain response to alcohol cues can vary substantially in spatial location within the brain. Retrospective analyses of TMS-AUD clinical trails has demonstrated that when TMS is delivered to an individual's peak brain response to alcohol cues, the likelihood of remaining abstinent is increased by a factor of 5.6 (relative to sham TMS treatment). This study aims to deliver one session of TMS to a cortical target which displays peak functional connectivity to the ventral striatum, a key brain region mediating reward and alcohol cue reactivity. The ultimate goal of this study evaluate change in brain reactivity to alcohol cues following active and sham TMS.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Between age 25 and 75.
  • Current DSM-5 diagnosis of moderate to severe AUD (≥4 diagnostic symptoms).
  • Able to attend scheduled clinic visits
  • Able to read, understand and voluntarily sign Informed Consent prior to participating in any study-specific procedures or assessments.
  • If on a medication regimen, that regimen will be stable for the duration of the study;
  • Fluency in English.

Exclusion criteria

  • Transcranial magnetic stimulation (TMS) and magnetic resonance imaging (MRI) contraindications: such as a cardiac pacemaker, cochlear implant, or an implanted device (deep brain stimulation, metal in the head, metal in the body, claustrophobia, pregnant or breastfeeding or other ferromagnetic device/objected in the head and body within 30 cm of the treatment coil.
  • General medical condition, disease or neurological disorder that interferes with the assessments or participation.
  • Unable to safely withdraw, at least two weeks prior to treatment, from medications that increase seizure risk.
  • Current substance abuse (except caffeine or nicotine) as determined by positive toxicology screen.
  • Have a mass lesion, cerebral infarct, or other active CNS disease, including an alcohol-related seizure or a seizure disorder. • A recent suicide attempt (defined as within the last 30 days) or presence of current suicidal plan or intent. Patients at risk for suicide will be required to establish a written safety plan involving their primary therapist before entering the study.
  • Severe impediment to vision, hearing and/or hand movement, likely to interfere with the ability to follow study protocols. • Greater than mild traumatic brain injury (defined as greater than 10 minutes loss of consciousness).
  • Taking benzodiazepine or neuroleptic medications, or any medication known to alter seizure threshold
  • unstable chronic illness.
  • Current or lifetime history of bipolar disorder or psychosis.
  • Participation in another concurrent intervention based clinical trial.

Treatment and study plan

Active Transcranial Magnetic Simulation

Device

1 session of active continuous theta burst stimulation (3600 pulses, 110% RMT) will be delivered to the cortical region demonstrating maximal functional connectivity with the striatum during alcohol cue presentation. TMS will be delivered using the Magventure MagPro X100.

Other names: MagVenture MagPro X100, Continuous Theta Burst Stimulation

SHAM

Device

1 session of sham continuous theta burst stimulation (3600 pulses, 110% RMT) will be delivered to the cortical region demonstrating maximal functional connectivity with the striatum during alcohol cue presentation. The MagVenture MagPro x100 is capable of administering a sham stimulation. The reverse side of the TMS coil is plated with a magnetic shield such that electromagnetic energy cannot stimulate the brain. The device offers compatibility with Transcutaneous Electrical Nerve Stimulation devices such that titrated electrical pulses can be delivered to the scalp location to mimic the sensation of a TMS pulse without stimulating the brain.

Other names: MagVenture MagPro X100

Primary outcomes

  1. Change in blood-oxygen level dependent signal as a measure of change in alcohol cue reactivity

    Time frame: Baseline (pre-TMS) and Day 2 (post-TMS)

    The effect of real versus sham fMRI-guided TMS on alcohol cue reactivity will be assessed by comparing brain reactivity to images of alcohol ('alcohol cues') shown during the fMRI scan. Change in blood-oxygen level dependent signal magnitude will be measured within the striatum, a key brain region involved in cue-reactivity.

Study contacts

Contact information is provided by the study sponsor or research team.

Daniel McCalley

CONTACT

[email protected]

650-493-5000

Sponsors and collaborators

Lead sponsor

VA Palo Alto Health Care System

Fed

Collaborators

  • National Institute on Alcohol Abuse and Alcoholism (NIAAA)
  • Stanford University

Registry information

Important dates

Study start
2025
Primary completion
2026
Study completion
2026
First posted
May 16, 2024
Registry last updated
Aug 13, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.