Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT06649396

Determination of New Detection and Quantification Thresholds for Serological and Molecular Tests for Hepatitis Delta Virus (HDV) Using Capillary Blood on Blotting Paper (DBS)

The Delta hepatitis virus (HDV) is a satellite virus that requires the presence of hepatitis B virus (HBV) for infection. Approximately 5% of HBV-infected individuals, or about 12 million people globally, are also carriers of HDV. This dual infection significantly heightens the risk of liver damage and the progression to hepatocellular carcinoma (HCC).

Historically, the diagnosis of HDV has been limited, leading to an underestimation of its true prevalence both nationally and internationally. Recent advancements in treatments for viral hepatitis and the introduction of new HDV-specific therapies have spurred increased interest in the virus, prompting public health authorities to call for improved diagnostic and monitoring tools.

Detection of HDV typically involves serological tests (ELISA/CLIA) on serum or plasma, followed by viral load quantification using RT-qPCR if positive. However, laboratory access is often insufficient in many regions, particularly affecting marginalized populations and high-endemic areas, especially in low-resource countries. New sample collection methods that help connect patients to expert laboratories are needed, as shipping frozen biological samples can be complex and costly.

In response, Dried Blood Spot (DBS) sampling-where serum, plasma, or whole blood is dried on filter paper-has been adopted by numerous public health organizations as a simple, cost-effective, and non-infectious means of storage and transport. DBS is already validated for diagnosing and monitoring infections such as HIV, HBV, and HCV.

Given the unique biology of each virus, specific studies are required to determine how using DBS affects detection and quantification thresholds for each laboratory technique. The National Reference Center for Delta Hepatitis (CNR-Delta), commissioned by Public Health France, has developed a DBS protocol for HDV, based on available literature and prior studies regarding storage conditions and reconstitution solutions. Two retrospective studies utilizing CNR collections have established new positivity thresholds for serology and detection/quantification in molecular biology for serum/plasma and EDTA whole blood on DBS.

To finalize this protocol, further study of thresholds for capillary blood tests on DBS is essential. Capillary blood, obtained via finger prick, could simplify the use of this tool, reducing the need for specialised equipment and expertise, and potentially allowing for self-sampling by patients.

The current study aims to validate the DBS tool for HDV serological and molecular testing using capillary blood. The hypothesis posits that geographical barriers to accessing hospitals and laboratories for HDV patients complicate the shipping of frozen plasma samples, increasing costs. Developing a serological screening and viral load testing technique from a drop of capillary blood on DBS paper could effectively link patients to specialized centers. Since DBS is considered non-infectious, it also mitigates administrative complications.

By comparing results from paired samples-plasma (the gold standard) from EDTA whole blood and capillary blood on DBS-we aim to redefine detection and quantification thresholds for both methods. Validating these new thresholds will allow the use of this tool while maintaining quality standards for diagnosing and monitoring active HDV infections.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Centre National de Référence associé de l'Hépatite Delta (CNR-Delta)

Bobigny, 93100, France

Location contact

Anaïs Vallet-Pichard

PRINCIPAL_INVESTIGATOR

Bruno Roche

PRINCIPAL_INVESTIGATOR

Jessica Coelho

PRINCIPAL_INVESTIGATOR

Julie Chas

PRINCIPAL_INVESTIGATOR

Ségolène Brichler, MCU-PH

CONTACT

[email protected]

01 48 95 75 96 ext. +33

Tarik Asselah

PRINCIPAL_INVESTIGATOR

Vincent Leroy

PRINCIPAL_INVESTIGATOR

Violaine Ozenne

PRINCIPAL_INVESTIGATOR

Véronique Grando

PRINCIPAL_INVESTIGATOR

About this study

The Delta hepatitis virus (HDV) is a satellite virus that requires the presence of hepatitis B virus (HBV) for infection. Approximately 5% of HBV-infected individuals, or about 12 million people globally, are also carriers of HDV. This dual infection significantly heightens the risk of liver damage and the progression to hepatocellular carcinoma (HCC).

Historically, the diagnosis of HDV has been limited, leading to an underestimation of its true prevalence both nationally and internationally. Recent advancements in treatments for viral hepatitis and the introduction of new HDV-specific therapies have spurred increased interest in the virus, prompting public health authorities to call for improved diagnostic and monitoring tools.

Detection of HDV typically involves serological tests (ELISA/CLIA) on serum or plasma, followed by viral load quantification using RT-qPCR if positive. However, laboratory access is often insufficient in many regions, particularly affecting marginalized populations and high-endemic areas, especially in low-resource countries. New sample collection methods that help connect patients to expert laboratories are needed, as shipping frozen biological samples can be complex and costly.

In response, Dried Blood Spot (DBS) sampling-where serum, plasma, or whole blood is dried on filter paper-has been adopted by numerous public health organizations as a simple, cost-effective, and non-infectious means of storage and transport. DBS is already validated for diagnosing and monitoring infections such as HIV, HBV, and HCV.

Given the unique biology of each virus, specific studies are required to determine how using DBS affects detection and quantification thresholds for each laboratory technique. The National Reference Center for Delta Hepatitis (CNR-Delta), commissioned by Public Health France, has developed a DBS protocol for HDV, based on available literature and prior studies regarding storage conditions and reconstitution solutions. Two retrospective studies utilizing CNR collections have established new positivity thresholds for serology and detection/quantification in molecular biology for serum/plasma and EDTA whole blood on DBS.

To finalize this protocol, further study of thresholds for capillary blood tests on DBS is essential. Capillary blood, obtained via finger prick, could simplify the use of this tool, reducing the need for specialised equipment and expertise, and potentially allowing for self-sampling by patients.

The current study aims to validate the DBS tool for HDV serological and molecular testing using capillary blood. The hypothesis posits that geographical barriers to accessing hospitals and laboratories for HDV patients complicate the shipping of frozen plasma samples, increasing costs. Developing a serological screening and viral load testing technique from a drop of capillary blood on DBS paper could effectively link patients to specialized centers. Since DBS is considered non-infectious, it also mitigates administrative complications.

By comparing results from paired samples-plasma (the gold standard) from EDTA whole blood and capillary blood on DBS-we aim to redefine detection and quantification thresholds for both methods. Validating these new thresholds will allow the use of this tool while maintaining quality standards for diagnosing and monitoring active HDV infections.

The benefits of the capillary blood on DBS protocol include:

  • For patients: Improved access to care regardless of geographic location and easier sampling (self-sampling).
  • For clinicians: Simplified management and extended screening to hard-to-reach populations.
  • For laboratories: Reduced transportation costs and infectious risk.
  • For the CNR: The opportunity to study global prevalence with a simplified protocol.

In summary, the "gold standard" for diagnosing and monitoring HDV infection involves serology on serum or plasma, testing for total anti-HDV antibodies followed by viral load quantification. To assess whether tests from dried capillary blood can replace plasma/serum tests, a comparative study is necessary, where plasma samples and a drop of capillary blood are collected simultaneously from the same patient and tested in parallel. This comparison will evaluate the sensitivity and specificity of the DBS tool using capillary blood and establish new detection and quantification thresholds for viral load on DBS.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adult patients (18 years old and above)
  • Patient infected by the Hepatitis Delta Virus (HDV positive serology)
  • Patient followed by one of the participating APHP hospitals' hepatology department
  • Patient for whom peripheral blood sampling is already planned as part of their medical follow-up.
  • Free, informed and signed consent.

Exclusion criteria

  • Patient without blood sampling scheduled as part of medical follow-up.
  • Patient with a condition that makes fingertip capillary puncture impossible.
  • Patient refusing to participate in the study

Treatment and study plan

Dried Blood Spot

Diagnostic Test

Comparing analysis results between dried blood spot and plasma

Analysis on plasma

Diagnostic Test

Analysis on plasma

Primary outcomes

  1. HDV serology

    Time frame: At enrollment

    Comparison between total anti-HDV antibody detection results on Diasorin Liaison XL on plasma obtained from peripheral blood (EDTA) and on capillary blood blotted onto filter paper.

  2. HDV viral load

    Time frame: At enrollment

    Comparison between HDV viral load results obtained by RT-qPCR (Eurobioplex EBX-071) on plasma from peripheral blood (EDTA) and capillary blotted onto filter paper.

Secondary outcomes

  1. Genotyping

    Time frame: At enrollment

    Comparison between R0 RNA sequences (SANGER) on plasma obtained from peripheral blood (EDTA) and capillary blood blotted onto filter paper.

Study contacts

Contact information is provided by the study sponsor or research team.

Frederic Le Gal, PhD

CONTACT

[email protected]

01 48 95 74 03 ext. +33

Valérian Delagarde, MSc

CONTACT

[email protected]

01 48 95 55 55 Poste 52747 ext. +33

Sponsors and collaborators

Lead sponsor

Institut de Médecine et d'Epidémiologie Appliquée - Fondation Internationale Léon M'Ba

Other

Collaborators

  • CNR Hepatite Delta

Registry information

Acronym: SACADE

Important dates

Study start
2024
Primary completion
2025
Study completion
2026
First posted
Oct 18, 2024
Registry last updated
Oct 18, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.