In recent years there has been increasing focus on the earlier detection of deterioration in the clinical condition of hospital patients with the aim of instigating earlier treatment to reverse this deterioration and prevent adverse outcomes. This is especially important in the ED, a dynamic environment with large volumes of undifferentiated patients, which carries inherent patient risk. SNAP40 is an innovative medical-grade device that can be worn on the upper arm that continuously monitors patients' vital signs including relative changes in systolic blood pressure, respiratory rate, heart rate, movement, blood oxygen saturation and temperature. It uses automated risk analysis to potentially allow clinical staff to easily and quickly identify high-risk patients. The aim of this study is to investigate whether the SNAP40 device is able to identify deterioration in the vital sign physiology of an ED patient earlier than current standard monitoring and observation charting techniques.
Looking for future studies?
Notify Me16 year and older
All sexes
Interventional
Not applicable
Edinburgh, Midlothian, EH16 4SA, United Kingdom
As well as the potential of the SNAP40 device to improve patient safety, we believe that the SNAP40 device will increase ED efficiency, improve and increase use of resources and enable improved patient flow through the ED. Currently the only option for continuous monitoring or regular observations in the ED is to connect the patient to a standard monitor. Whilst these monitors can be portable they are not lightweight enough to allow the patient to be ambulatory within the ED and therefore require the patient to have a bed and a bed space or cubicle. This leads to lack of space within the ED, less cubicles (which allow privacy) free for performing history taking, examination and procedures, difficulty accessing patients and difficulty transporting them to areas where specialist tests can be performed (i.e. radiology and ECG). SNAP40 may remove the need for patients to be confined to beds and bed spaces (unless clinically required) freeing up space within the ED and allowing the ED care processes to occur much more freely increasing efficiency and speed of patient processing. This will undoubtedly lead to improved patient experiences around their ED and hospital journey.
The SNAP40 device also has the potential to free up resources, which can be used to improve patient care and experience in the ED. SNAP40 may reduce clinical staff time taken to record observations enabling them to provide patients with other aspects of care (i.e. analgesia and treatments) more regularly and in a timelier manner. Clinical staff may be able to spend more time with patients allowing better quality communication with them and their relatives. There will potentially be more time for traditional nursing care and personal care.
Whilst there are some other similar medical devices on the market (i.e. www.biovotion.com, www.sensium-healthcare.com, www.vitalconnect.com, http://www.caretakermedical.net) using wristbands, patches or finger cuff technology, currently none are being used in ED clinical practice.
This study will examine the SNAP40 device by comparing its performance to detect physiological deterioration against standard observations taken by clinical staff (nurses, doctors and clinical support workers) within the ED. The study will assess whether the device is able to detect physiological derangement sooner that standard monitoring devices.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
SNAP40 ambulatory monitoring device
Time frame: 4 hours
Time to detection of deterioration in an ED patient's vital sign physiology defined as an increase in NEWS score. This would include a deterioration in blood pressure, pulse/heart rate, respiratory rate, skin temperature (SNAP40)/core temperature (Standard), oxygen saturation reading or movement (SNAP40)/GCS (Standard).
Time frame: 4 hours
Time ED staff spend performing a charting observations and responding to standard monitoring alarms.
Time frame: 4 hours
Percentage clinical escalation of care when deterioration detected.
Time frame: 4 hours
Participants rating of experience of both SNAP40 and current monitoring.
Time frame: 4 hours
ED staff rating of experience of both SNAP40 and current monitoring.
NHS Lothian
Other Gov
Detection of Physiological Deterioration by the SNAP40 Wearable Device Compared to Standard Monitoring Devices in the Emergency Department
Acronym: SNAP40ED
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07676227
Vital Sign Monitoring, Vital Signs
Tampere, Finland
View Trial DetailsNCT04725747
Vital Signs
Sioux Falls, South Dakota, United States
View Trial DetailsNCT07194122
Elderly (People Aged 65 or More), Vital Signs
Usansolo, Bizkaia, Spain
View Trial DetailsNCT07009275
Academic Acheivement, Animation
İzmit, Kocaeli, Turkey (Türkiye)
View Trial Details