University of Nebraska at Omaha Health Science Collaborative
Omaha, Nebraska, 68182, United States
Location status: Recruiting
NCT Number: NCT07226193
1) The purpose of this study is to assess segmental pulse arrival time (PAT) as an alternative biomarker to detect lower-extremity peripheral artery disease (PAD), and to investigate the impacts of local skin heating and foot elevation. The secondary purpose will be to investigate the impacts of age on segmental PAT. The subject population will include any adults 19 years of age or older with or without PAD. Exclusion criteria include having an aortic aneurysm with or without previous intervention, previous revascularization surgeries of the arteries in the legs/aorta, walking impairments independent of PAD, gangrene or ulcers of the toes/feet, and currently pregnant or breastfeeding. 3) All aims of the present study will be completed with a single laboratory visit. Descriptive measurements will include height, weight, age, sex, body fat percentage, and self-reported medication and health history. Subjects will lie in the supine position for 20-min. After rest, either the ankle-brachial index (ABI) or PAT will be assessed. After 10-min of further rest, the other measurement will be performed. ABIs will be assessed according to current guidelines: blood pressures will be assessed in the dorsal pedis and tibialis posterior arteries of both legs and the brachial arteries of both arms using a blood pressure cuff and Doppler ultrasound. PAT will be simultaneously assessed in both arms and legs using an investigational device with a 3-lead electrocardiogram sensor and four photoplethysmography (PPG) sensors. A PPG sensor will be applied to a finger on each hand and both big toes. Signals will be collected for 15-min with finger and toe sensor temperatures at 30 C. Toe sensor temperature will then be elevated to 45 C for 15-min. Finally, toe sensor temperature will remain at 45 C, and the feet will be elevated 8-in with a soft cushion for 15-min. Blood pressure in the arm and legs will be assessed at the end of each stage. Thermal images of the fingers and toes will be assessed before using the investigational device and after each stage. Subjects will then participate in a 6-min walking test (6MWT) to objectively establish walking capacity. The 6MWT will be performed in accordance with current guidelines. Segmental PATs will be compared with ABI and 6-min walking time to determine if segmental PATs can predict lower-extremity PAD (ABI) and the associated walking impairment (6MWT). This study is expected to last ~2.5hrs. 4) There will be no follow-up.
Interested in participating?
Request Info19 year and older
All sexes
Interventional
Not applicable
Omaha, Nebraska, 68182, United States
Location status: Recruiting
Specific Aim 1: Determine if segmental pulse arrival times can predict lower-extremity peripheral artery disease assessed with ankle-brachial index and the 6-min walking test.
Specific Aim 2: Determine if local skin heating of the toes and foot elevation improves the prediction of peripheral artery disease using segmental pulse arrival times.
Specific Aim 3: Determine the effects of age on segmental pulse arrival times.
After the process of informed consent, descriptive measurements will be assessed. Descriptive measures include height, weight, body composition, age, and sex. Height and weight will be assessed with a standard stadiometer and scale, respectively. Body composition will be assessed non-invasively with bio-electric impedance analysis (Omron HBF-306C Handheld Scanner, OMRON Healthcare, Kyoto, Japan). Bioelectric impedance devices send a small electric current through the body and estimates body fat percentage based on the impedance to electrical flow through the body segments. Our bio-electric impedance device creates a circuit between the hands and feet of the subject to estimate body fat percentage. The electric current used in bioelectric impedance devices is very small and cannot be felt by the participant. Subjects will also self-report their medication and health history.
After the assessment of descriptive measurements, subjects will rest in the supine position for 20-min. After 20-min of rest, the subjects will have either ankle-brachial index (ABI) or segmental pulse arrival times (PATs) assessed. After a 10-min period of rest, the other measurement will be assessed (either ABI or PAT). The order of ABI and PAT will be randomized, and all subjects will have ABI and PAT assessed.
1a) Assessment of PAT with the Investigational Device: The subjects will be instrumented with an investigational device comprised of an array of four photoplethysmography (PPG) sensors and one 3-lead electrocardiogram (ECG) sensor. Electrocardiogram is a non-invasive technique that is used to monitor the electrical dipoles generated by membrane potentials within the myocardium and electrical conduction systems of the heart. PPG is a non-invasive technique to assess hemoglobin content within the microcirculation of the skin. Our PPG sensors are applied superficially on the skin and shines continuous-intensity green light into the skin (580 nm). The green light is absorbed by hemoglobin. Therefore, by the modified Beer-Lambert principle, the amount of light reflected back to the PPG unit gives an index of hemoglobin content within the microvasculature. The PPG and ECG sensors are integrated into a microcontroller (small computer), which reads the voltages of the sensors and displays the data in real time in a custom computer software. Each PPG sensor will have a skin-safe double-sided adhesive attached to the sensor housing. A PPG sensor will be adhered to a finger on the palmar side of both hands. A PPG sensor will be adhered to the plantar aspect of both big toes. Altogether, there will be one PPG sensor per hand and one PPG sensor per foot. The ECG sensor will be applied to form limb leads: one electrode per wrist on the ventral aspect of the forearm and one electrode on a hair-free portion of the left leg. If an adequate ECG signal is not obtained using limb leads, then chest leads will be utilized. In this configuration, electrodes will be placed inferior to the left and right clavicle, and medial to the shoulders, and one electrode will be placed on the left lateral aspect of the ribcage near the apex of the heart. Once all sensors have been placed, the subject will rest in the supine position. Next, the temperature of the sensor housings attached to the fingers and toes will be warmed to 30 C, which is thermoneutral with skin temperature, and subjects will rest for 15-min. Blood pressure will then be assessed in the arm and legs with a standard automatic blood pressure device. After 15-min of signal collection, the toe sensor housings will be heated to 45 C to warm up the skin of the toes, and the finger sensor housings will remain warmed at 30 C for an additional 15-min. Blood pressure will then be assessed in the arm and legs with a standard automatic blood pressure device. Next, the lower legs will be elevated 8-in with a soft cushion. The toe sensors will remain heated at 45 C, and the finger sensors will remain at 30 C. Signals will be collected continuously for an additional 15-min. Finally, blood pressure will then be assessed in the arm and legs with a standard automatic blood pressure device. For all conditions, PAT will be calculated for each arm and each leg as the difference in time between the R-wave appearing in the ECG signal and the pulse wave appearing in the distal PPG signals. All four PAT values will be used to develop a composite score to estimate the presence of lower-extremity PAD. Leg asymmetry will be assessed with the ratio of PATs from left and right legs. Atherosclerotic plaque-mediated pulse wave slowing will be assessed as the ratio of PATs in the arms compared to the legs. The product of these ratios forms the composite score to detect lower-extremity PAD, which is sensitive to both 1) asymmetry in PATs in the legs (may indicate unilateral lower-extremity PAD) and 2) longer PATs in the legs compared to the arms (may indicate the presence of lower-extremity PAD).
1b) Thermal Imaging:A thermal imaging camera (FLIR T540) will be used to take thermal images of the skin where the PPG sensors will be/were applied. Thermal images will be taken 1) prior to all sensors being applied, 2) after warming the finger and toe sensors to 30 C, 3) after warming the finger sensors to 30 C and the toe sensors to 45 C without leg elevation, and 4) after warming the finger sensors to 30 C and the toe sensors to 45 C with leg elevation. The purpose of using the thermal camera is to document the local skin temperature before and after using the investigational device at each setting. The thermal camera will automatically select the warmest region of the image and document the temperature. Of note, the thermal imaging camera will be zoomed in on the fingers and toes where the PPG sensors were located, and no identifiable body parts (e.g., face) or clusters of body parts (e.g., zoomed out images) will be included in the thermal images. Therefore, the risk of identifying subjects with the thermal images will be minimized.
The study duration is expected to be ~2.5 hrs, and there will be no follow-up.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
A proprietary device has been developed to obtain segmental pulse arrival times in the arms and legs. Using this information, the propagation time of the pulse is being investigated as a biomarker to detect the presence of lower-extremity atherosclerosis. Furthermore, the impacts of aging on the biomarker will be assessed.
Time frame: Day 1
Pulse arrival time will be assessed in both arms and legs with the investigational device
Time frame: Day 1
Segmental blood pressures in the arms and ankles will be assessed as an index of the presence and/or severity of lower-extremity atherosclerosis. The ankle-brachial index is the standard screening assessment for peripheral artery disease in the lower-extremities.
Time frame: Day 1
The 6-min walking test is a standard assessment of mobility in older adults and in patients with peripheral artery disease. The 6-min walking test will be performed to quantify the level of walking impairment in patients with peripheral artery disease.
Contact information is provided by the study sponsor or research team.
Cody P Anderson
CONTACT
Gwenael Layec, PhD
CONTACT
University of Nebraska
Other
Pulse Arrival Time as an Alternative Biomarker to Detect Lower-Extremity Peripheral Artery Disease
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03304821
Arterial Occlusive Diseases, Arteriosclerosis
Atlanta, Georgia, United States
View Trial DetailsNCT07318610
Arterial Occlusive Diseases, Arteriosclerosis
Alexander City, Alabama, United States
View Trial DetailsNCT06687590
Arterial Occlusive Diseases, Arteriosclerosis
Scottsdale, Arizona, United States
View Trial DetailsNCT07169045
Arterial Occlusive Diseases, Arteriosclerosis
Ankara, Çankaya, Turkey (Türkiye)
View Trial Details