Respiratory resistor
OtherThe volunteers are breathing through the four respiratory resistors (inspiratory, expiratory, combined in- and expiratory and no resistor) in order to increase the intrathoracic pressure svings
NCT Number: NCT02549482
13 healthy volunteers (4 females) were tilted 45° head-up while breathing through a facemask fitted with an inspiratory and expiratory resistor. A brachial arterial catheter was used to measure blood pressure and thus systolic pressure variation and pulse contour analysis determined stroke volume and thereby cardiac output in order to detect a central volume deficit.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Thirteen healthy volunteers (4 women) at an age of 25 years (range 18-36) were recruited through www.forsøgsperson.dk.
The volunteers were placed on a tilt table and provided with a facemask with an opening of 30-33 mm. A Hook ring was fitted with an inspiratory resistor, an expiratory resistor, a combination of the two resistors, or with no resistance and each resistor provides a 7.5 cmH2O threshold resistance. Each resistor was applied for two minutes with variables obtained in the last minute. The table was then tilted 45° head-up to accumulating blood in the legs and therefore a reduction in the central blood volume. Conversely, 20° head-down tilt was used to expand the central blood volume. For each volunteer measurements with the four respiratory interventions was randomized, whereas the tilt table position was in fixed order: supine, head-up tilt, and head-down tilt.
Three-lead ECG recorded heart rate. A 20 G arterial catheter was placed in the brachial artery of the non-dominant arm and connected to a transducer for reading of blood pressure and stroke volume variation (Vigileo-Flotrac™, version 1.07, Edwards Lifesciences, Nyon, Switzerland). Also SV and CO variation and the arterial pressure curve were recorded for subsequent determination of arterial pressure variations. Additionally, a catheter was placed via a brachial vein to the superior caval vein for recording of central venous pressure and SvO2. While the subjects were breathing spontaneously, the respiratory rate was measured by capnography and peripheral oxygen saturation by fingerprobe.
Variation in the arterial pulse pressure (PPV) was 100 x ((PPmax - PPmin) / ((PPmax + PPmin)/2)), where PPmax and PPmin is the maximal and minimal difference between systolic and diastolic pressure during the respiratory cycle, respectively. By the same formula systolic pressure variation (SPV) was calculated.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The volunteers are breathing through the four respiratory resistors (inspiratory, expiratory, combined in- and expiratory and no resistor) in order to increase the intrathoracic pressure svings
Time frame: Two minutes
Relative difference between systolic blood pressure during inspiration and expiration. Meassured in percent.
Aalborg University Hospital
Other
Detecting a Central Volume Deficit in Spontaneous Breathing Healthy Volunteers by Systolic Blood Pressure Variation
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04186416
Fluid Responsiveness, Hemorrhage
Paris, France
View Trial DetailsNCT05705115
Fluid Loss, Hemodynamic Instability
Oslo, Norway
View Trial DetailsNCT05054452
Critical Illness, Disease Attributes
Le Kremlin-Bicêtre, France
View Trial DetailsNCT02193412
Hypovolemia, Neurologic Manifestations
Lille, Nord, France
View Trial Details