Acuvue Oasys 1 Day for Astigmatism
DeviceCONTROL
NCT Number: NCT05778786
This will be a 4-visit, randomized, controlled, single-masked, bilateral wear, dispensing, 2-treatment, 2-sequence, 2-period crossover study.
Looking for future studies?
Notify Me18 year–39 year
All sexes
Interventional
Not applicable
Stam & Associates Eye Care, Jacksonville, Florida, United States
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
The subject must:
Exclusion criteria
The subject must not:
CONTROL
TEST
Time frame: 1-Week Follow-up
Distance Monocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. Visual acuity is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20.
Time frame: 1-Week Follow-up
Subjective vision was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120.
Time frame: 15-minutes after lens insertion
Absolute rotation was assessed for each subject eye using a slit lamp 15-minutes after lens insertion. Acceptable absolute rotation was dichotomized into a binary response where Y=1 if absolute rotation was less than or equal to 10 degrees and Y=0 otherwise (absolute rotation greater than 10 degrees). The proportion of eyes with absolute rotation less than or equal to 10 degrees was report for each lens.
Time frame: 15-minutes after lens insertion
Rotational Stability was assessed for each subject eye using a slit lamp 15-minutes after lens insertion. Rotational Stability was dichotomized into a binary response where Y=1 if Rotational Stability was less than or equal to 5 degrees and Y=0 otherwise (Rotational Stability greater than 5 degrees). The proportion of eyes with Rotational Stability less than or equal to 5 degrees was report for each lens.
Time frame: Up to 1-Week Follow-up
Contact lens fitting acceptance was assessed for each subject eye using a biomicroscope post lens insertion at the 1-week follow-up. Lens fit was a binary variable where acceptable lens fit=1 and unacceptable lens fit=0. The proportion of eyes with acceptable lens fit was reported for each lens.
Time frame: Up to 1-Week Follow-up
Slit Lamp Findings (SLF) were assessed using a biomicroscope and was graded using the FDA grading scale (Grade: 0, 1,2, 3 and 4) with grade 0 represents the absence of findings and 1 to 4 representing successively worse findings (i.e. Grade 1 = trace, Grade 2 = Mild, Grade 3 = moderate and Grade 4 = severe). This was performed on each subject eye at every study visit (baseline, unscheduled visits and 1-week follow-up). The data was then dichotomized into two groups. Those with grade 3 or higher and those with grade 2 or lower. The proportion of eyes with SLF with grade 3 or higher was reported for each lens.
Time frame: 1-Week Follow-up
Subjective comfort was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE comfort score was reported.
Time frame: 1-Week Follow-up
Subjective handling was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE handling score was reported.
Johnson & Johnson Vision Care, Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07174596
Visual Acuity
Roswell, Georgia, United States
View Trial DetailsNCT07076160
Eye Diseases, Presbyopia
Jacksonville, Florida, United States
View Trial DetailsNCT06864858
Visual Acuity
Maitland, Florida, United States
View Trial DetailsNCT07443215
Visual Acuity
Jacksonville, Florida, United States
View Trial Details