Local de Saúde São José
Portugal, 1150-199
Location status: Recruiting
Location contact
Ana Luisa Basílio, MD
CONTACT
Rita Anjos, MD
CONTACT
NCT Number: NCT06839443
Hydroxychloroquine retinal toxicity affects a significant number of patients using this medication. Detection of toxicity is difficult in the early stages of the disease and depends on the subjectivity of the clinician who reads the tests (optical coherence tomography, autofluorescence and visual fields). Automating the reading of these diagnostic exams could lead to earlier detection of this pathology and reduce the burden associated with interpreting these exams in the ophthalmology service. The images that are usually taken in the screening and monitoring of hydroxychloroquine toxicity by will be collected - photography of the ocular fundus and optical coherence tomography with autofluorescence.
Interested in participating?
Request Info18 year–100 year
All sexes
Observational
Portugal, 1150-199
Location status: Recruiting
Ana Luisa Basílio, MD
CONTACT
Rita Anjos, MD
CONTACT
HCQ is one of the most prescribed drugs worldwide. Originally developed for the treatment and prevention of malaria, it was soon proven effective for several other non-related disorders, most commonly non-organ specific autoimmune diseases. The use of HCQ in patients with systemic lupus erythematosus (SLE), for example, is estimated at 50%, increasing to 90% in specialized centers. These numbers are likely to increase following the LUMINA study that found a survival benefit of SLE patients on HCQ. In recent years, HCQ indications have been expanding to other medical areas such as dermatological disorders and oncology. Adding to the growing list of clinical indications, there are other factors that increase HCQ prescription such as a favourable safety profile and the possibility of adjunctive use with primary therapies, leading to a growing confidence amongst physicians to start treatment.
But HCQ is not an innocuous drug. There are several HCQ related adverse effects, either from acute or chronic intake, in particular in the nervous and cardiovascular system. It is estimated that around 1.8-7.5% of patients with more than 5 years of HCQ therapy suffer from retinal toxicity, with prevalence increasing to 20% after 20 years. Other known risk factors for toxicity are a higher dose, kidney failure and concomitant tamoxifen use and it has been suggested that previous macular pathology and genetic factors should be taken in account when calculating disease probability. Due to increase in HCQ usage, HCQ maculopathy and subsequent screening has become a public health problem. Although toxicity is directly related to drug use, retinal degeneration might continue despite drug cessation, which adding to the increase of users empathises the need for early disease detection. HCQ maculopathy screening guidelines differ slightly from country to country and have been evolving over time. The American Academy of Ophthalmology recommends baseline examination with OCT, autofluorescence and visual fields with annual review after 5 years unless there are other risk factors. On the other hand, the Royal College of Ophthalmology currently suggests annual monitoring 5 years after drug therapy with OCT and Widefield FAF unless there are other risk factors.
Deep learning techniques are paving the way in image-centric specialities and promise to lower healthcare costs and increase accuracy when compared to current methods. In ophthalmology, systems are being developed for the detection of diabetic retinopathy, glaucoma and age-related macular degeneration with high sensitivity and sensibility. We believe that using RETINAI technology and a sequential analysis of HCQ toxicity patients, a higher prediction model could be achieved. Three blinded readers will validate data as controls or toxicity.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
OCT scans and Retinai algorithm will be performed
OCT scans and Retinai algorithm will be performed
Time frame: One year
We hypothesize that HCQ toxicity can be detected with a deep learning system with OCT
Time frame: One year
We hypothesize that deep learning in OCT might provide an accurate tool for the early detection of HCQ toxicity
Contact information is provided by the study sponsor or research team.
Ana Luisa Basílio, MD
CONTACT
Rita Anjos, MD
CONTACT
Centro Hospitalar de Lisboa Central
Other
Acronym: PLAQUINAI
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.