NCT Number: NCT01205568
Cutting Balloon Study
The primary objective of this study is to evaluate the safety and efficacy of transcatheter Cutting Balloon therapy for branch pulmonary artery stenosis resistant to low pressure dilation.
Looking for future studies?
Notify MeKey information
Conditions
Sex eligibility
All sexes
Study type
Interventional
Phase
Not applicable
Primary location
University of California at San Francisco, San Francisco, California, United States
About this study
The proposed study will be a prospective, multi-center, randomized, blinded trial comparing 2 treatments for pulmonary artery stenosis. Specifically, vessels that fail to respond to balloon inflation at 8 ATM will be individually randomized to 1 of 2 treatment pathways. In the first treatment pathway, the vessel is dilated using a CB, followed by additional low pressure balloon dilation (< 8ATM). In the second pathway,the vessel is dilated with high pressure balloon angioplasty, with balloon inflation pressures exceeding 15 ATM. Cross-over therapy will be permitted for failed high pressure treatment starting with enrollment of patient #15. The primary outcome assessment for efficacy will be a comparison of percent change in minimum lumen diameter before and after randomized therapy, as determined by a core laboratory blinded to pathway assignment. The primary outcome assessment for safety will be a comparison of the proportion of vessel dilations resulting in any serious adverse events, as determined by the Data and Safety Monitoring Board. Patient-level safety endpoints will also be tabulated. Patients can have multiple vessels enrolled; analytical techniques will adjust for potential intra-patient correlation.
Who can participate
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Patient Inclusion Criteria (Determined Prior to Cardiac Catheterization)
a. At least 1 branch pulmonary artery stenosis referred for planned catheterization for PA dilation b. At least one of the following: i.greater than one half systemic right ventricular pressure ii. regional decrease in pulmonary blood flow by lung scan iii. elevated pulmonary artery pressures (> 20 mmHg MPAP) iv. cyanosis at least in part due to PA stenosis c. Informed consent of patient and/or parent/guardian; assent of mature minors d. Agreement to participate in protocol, including follow-up testing
Vessel Inclusion Criteria (Determined During Cardiac Catheterization)
- Native pulmonary artery or branch which fails balloon dilation up to 8 ATM; as defined by failure to eliminate a waist
- Native pulmonary artery or branch with a balloon waist diameter less than 7.5 mm (i.e.,0.5 mm less than the largest available CB) with dilation at 8 ATM
- All eligible vessels that are dilated during the catheterization must be enrolled as study vessels; "off-study" use of Cutting Balloons or high pressure dilations in eligible vessels is not allowed.
Exclusion criteria
- Patient Exclusion Criteria (Determined Prior to Cardiac Catheterization)
- Prior pulmonary artery angioplasty or surgery on the vessel within the previous 6 weeks
- Pregnancy
Vessel Exclusion Criteria (Determined During Cardiac Catheterization)
- Vessel with an aneurysm from a prior dilation or surgery, defined as a local enlargement of the vessel greater than 100% of the lumen diameter both proximally and distally to the aneurysm. The maximum aneurysm diameter and vessel lumen diameter proximal and distal to the aneurysm will be recorded. The location of the aneurysm relative to the angioplasty site will be determined and reported as proximal, distal, or in the region of waist formation.
- Prior stent placement associated with the obstruction
i. balloon inflation for the purpose of expanding the diameter of the stent along its length with no residual waist proximal or distal to the stent edges ii. balloon inflation resulting in waist formation within the edges of a stent iii. dilation of a vessel through the cells of a stent c. Unifocalized nor non-unifocalized systemic to pulmonary artery collaterals. d. A vessel requiring therapy at a site not amenable to delivery or safe positioning of a Cutting Balloon device due to unfavorable anatomy as determined by the physician and based on as assessment of vessel angles, size, length, and proximity to other vessels.
Treatment and study plan
High Pressure Balloon Angioplasty
ProcedurePrimary outcomes
-
Acute Change in Minimum Lumen Diameter Immediately Post-intervention
Time frame: Pre-intervention to immediate post-intervention (approximately 10 minutes)
The primary efficacy outcome is the percent change in minimum lumen diameter from pre-intervention to immediately post-intervention as measured by angiography.
Secondary outcomes
-
Percent Change in Minimum Lumen Diameter at 3 Months Post-intervention
Time frame: 3 months post-intervention
Late percent change in minimum lumen diameter from pre-intervention to follow-up angiography.
Sponsors and collaborators
Lead sponsor
Boston Children's Hospital
Other
Registry information
Official study title
Safety and Efficacy of the Cutting Balloon to Treat Resistant Pulmonary Artery Stenosis
Acronym: CB
Important dates
- Study start
- 2003
- Primary completion
- 2009
- Study completion
- 2009
- First posted
- Sep 20, 2010
- Registry last updated
- May 25, 2018
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Related clinical trials
Published trials that share one or more normalized conditions with this study.
Evaluation of Visceral Pleural Lumbar Lymphatic Drainage
NCT03628326
Arterial Occlusive Diseases, Cardiovascular Diseases
Amiens, France
View Trial DetailsRetrospective Review of Anesthetic Considerations for Pulmonary Artery Rehabilitation
NCT02586740
Arterial Occlusive Diseases, Cardiovascular Abnormalities
Columbus, Ohio, United States
View Trial DetailsMinima Stent System Post- Approval Study (PAS)
NCT06828770
Aortic Coarctation, Arterial Occlusive Diseases
Los Angeles, California, United States
View Trial DetailsPost-Approval Study of PALMAZ MULLINS XD™ in Treating Pulmonary Artery Stenosis
NCT07122518
Arterial Occlusive Diseases, Cardiovascular Diseases
View Trial Details