Skip to main content
OpenTrials
Completed

NCT Number: NCT01205568

Cutting Balloon Study

The primary objective of this study is to evaluate the safety and efficacy of transcatheter Cutting Balloon therapy for branch pulmonary artery stenosis resistant to low pressure dilation.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University of California at San Francisco, San Francisco, California, United States

Loading trial locations.

About this study

The proposed study will be a prospective, multi-center, randomized, blinded trial comparing 2 treatments for pulmonary artery stenosis. Specifically, vessels that fail to respond to balloon inflation at 8 ATM will be individually randomized to 1 of 2 treatment pathways. In the first treatment pathway, the vessel is dilated using a CB, followed by additional low pressure balloon dilation (< 8ATM). In the second pathway,the vessel is dilated with high pressure balloon angioplasty, with balloon inflation pressures exceeding 15 ATM. Cross-over therapy will be permitted for failed high pressure treatment starting with enrollment of patient #15. The primary outcome assessment for efficacy will be a comparison of percent change in minimum lumen diameter before and after randomized therapy, as determined by a core laboratory blinded to pathway assignment. The primary outcome assessment for safety will be a comparison of the proportion of vessel dilations resulting in any serious adverse events, as determined by the Data and Safety Monitoring Board. Patient-level safety endpoints will also be tabulated. Patients can have multiple vessels enrolled; analytical techniques will adjust for potential intra-patient correlation.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Patient Inclusion Criteria (Determined Prior to Cardiac Catheterization)

a. At least 1 branch pulmonary artery stenosis referred for planned catheterization for PA dilation b. At least one of the following: i.greater than one half systemic right ventricular pressure ii. regional decrease in pulmonary blood flow by lung scan iii. elevated pulmonary artery pressures (> 20 mmHg MPAP) iv. cyanosis at least in part due to PA stenosis c. Informed consent of patient and/or parent/guardian; assent of mature minors d. Agreement to participate in protocol, including follow-up testing

Vessel Inclusion Criteria (Determined During Cardiac Catheterization)

  • Native pulmonary artery or branch which fails balloon dilation up to 8 ATM; as defined by failure to eliminate a waist
  • Native pulmonary artery or branch with a balloon waist diameter less than 7.5 mm (i.e.,0.5 mm less than the largest available CB) with dilation at 8 ATM
  • All eligible vessels that are dilated during the catheterization must be enrolled as study vessels; "off-study" use of Cutting Balloons or high pressure dilations in eligible vessels is not allowed.

Exclusion criteria

  • Patient Exclusion Criteria (Determined Prior to Cardiac Catheterization)
  • Prior pulmonary artery angioplasty or surgery on the vessel within the previous 6 weeks
  • Pregnancy

Vessel Exclusion Criteria (Determined During Cardiac Catheterization)

  • Vessel with an aneurysm from a prior dilation or surgery, defined as a local enlargement of the vessel greater than 100% of the lumen diameter both proximally and distally to the aneurysm. The maximum aneurysm diameter and vessel lumen diameter proximal and distal to the aneurysm will be recorded. The location of the aneurysm relative to the angioplasty site will be determined and reported as proximal, distal, or in the region of waist formation.
  • Prior stent placement associated with the obstruction

i. balloon inflation for the purpose of expanding the diameter of the stent along its length with no residual waist proximal or distal to the stent edges ii. balloon inflation resulting in waist formation within the edges of a stent iii. dilation of a vessel through the cells of a stent c. Unifocalized nor non-unifocalized systemic to pulmonary artery collaterals. d. A vessel requiring therapy at a site not amenable to delivery or safe positioning of a Cutting Balloon device due to unfavorable anatomy as determined by the physician and based on as assessment of vessel angles, size, length, and proximity to other vessels.

Treatment and study plan

Transcatheter Cutting Balloon therapy

Device

High Pressure Balloon Angioplasty

Procedure

Primary outcomes

  1. Acute Change in Minimum Lumen Diameter Immediately Post-intervention

    Time frame: Pre-intervention to immediate post-intervention (approximately 10 minutes)

    The primary efficacy outcome is the percent change in minimum lumen diameter from pre-intervention to immediately post-intervention as measured by angiography.

Secondary outcomes

  1. Percent Change in Minimum Lumen Diameter at 3 Months Post-intervention

    Time frame: 3 months post-intervention

    Late percent change in minimum lumen diameter from pre-intervention to follow-up angiography.

Sponsors and collaborators

Lead sponsor

Boston Children's Hospital

Other

Registry information

Official study title

Safety and Efficacy of the Cutting Balloon to Treat Resistant Pulmonary Artery Stenosis

Acronym: CB

Important dates

Study start
2003
Primary completion
2009
Study completion
2009
First posted
Sep 20, 2010
Registry last updated
May 25, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.