Faculty of dentistry, Alexandria university
Alexandria, 21523, Egypt
NCT Number: NCT07156812
This investigation aimed to determine the clinical and radiographic efficacy of patient-specific, custom-made 3D PEEK plates in comparison with 3D titanium plates for the management of mandibular angle fractures.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Phase 4
Alexandria, 21523, Egypt
Eighteen patients with recent mandibular angle fractures indicated for open reduction and internal fixation were randomly allocated into two groups. The study group (n = 9) underwent fixation with custom-made 3D PEEK plates, while the control group (n = 9) received prebent 3D titanium plates adapted on virtually reduced models. Follow-up extended to 12 weeks. Clinical parameters included operative time, postoperative occlusion, interfragmentary stability, wound healing, and bite force recovery. Radiographic evaluation was conducted using computed tomography scans acquired immediately postoperatively and at 12 weeks, assessing fracture healing and mean bone density.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Custome made 3D PEEK plate
Pre-bent 3D Titanium plate
Time frame: 12 weeks
Mean bone density at the fracture line was assessed using Computed Tomography (CT) scan in Hounsfield Units (HU)
Time frame: 12 weeks
bite force recovery measured by a Piezoresistive force transduce sensor: FlexiForce A201 sensor (FlexiForce sensor, by Tekscan Boston, MA, USA. www.tekscan.com)
Time frame: 12 weeks
Intra-fragmentary mobility was evaluated by bimanual palpation at the fracture site
Time frame: 14 days
Wound healing is graded according to Southampton wound-grading system
Time frame: 12 week
By checking the maximal intercuspal position (centric occlusion) to ensure proper occlusal relationship including molar relation, canine relation and midline centralization
Alexandria University
Other
Custom-Made 3D PEEK Plates Versus 3D Titanium Plates in Mandibular Angle Fracture Fixation: A Randomized Controlled Clinical Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07375030
Mandibular Angle Fracture
Alexandria, Egypt
View Trial DetailsNCT07231042
Craniocerebral Trauma, Facial Injuries
Tanta, Gharbia Governorate, Egypt
View Trial DetailsNCT07390734
Mandibular Angle Fracture
Alexandria, Egypt
View Trial DetailsNCT06622642
Mandibular Angle Fracture, Surgical Approach &Amp; Incisions
Lahore, Punjab Province, Pakistan
View Trial Details