NCT Number: NCT01248741
High Dose Rate (HDR) temporary prostate brachytherapy offers a precise form of dose escalation for prostate cancer. Needles are placed, the position is confirmed and treatment is delivered. Previously High Dose Rate prostate brachytherapy was performed under TransRectal UltraSound (TRUS) guidance but planned with Computed Tomography (CT) imaging which introduced a source of error through needle displacement while transporting and repositioning patient. Recently Varian has introduced a one-step procedure where both implant and planning are based on UltraSound imaging and performed without patient repositioning. This planning system is approved by Health Canada and is commercially available.
This study will use High Dose Rate brachytherapy to treat 20 men. Treatment will be planned with TransRectal UltraSound and validated using Computed Tomography imaging.
Looking for future studies?
Notify Me45 year–80 year
Male
Interventional
Not applicable
Kelowna, British Columbia, V1Y 5L3, Canada
Twenty men with intermediate risk prostate cancer, suitable for the combination of external beam radiotherapy and High Dose Rate brachytherapy will be entered in this study. High Dose Rate brachytherapy will be performed using TransRectal UltraSound guidance and then planned using both cone-beam Computed Tomography and TransRectal UltraSound. Planning by Computed Tomography is to check the reliability and reproducibility of UltraSound imaging to correctly identify the needle positions. Correct needle localization is essential because this is the basis for determining source dwell positions, dose calculation and dose optimization.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
HDR prostate brachytherapy to be delivered in 2 fractions of 10 Gray as a "boost" combined with external beam radiotherapy
Time frame: Treatment was planned and delivered based on ultrasound identification of needles and needle tips relative to prostate. All measurements and comparisons of measurements pertain to the day of the procedure.
Precise location of the tip of each needle in 3-dimensional space relative to the prostate determines the pattern of dose delivery. Inaccuracies in needle tip location may lead to differences detected between UltraSound(US)-based and Computed Tomography (CT)-based plans.The distance of the needle tip (as identified on either CT images or US images) protruding beyond the template was measured in mm. The template acted as a fixed reference point as it was locked into the stabilizer/stepper apparatus. The 2 protrusion readings for each needle tip were compared, the difference recorded in mm, and categorized as < 1 mm, 1-2 mm, 2-3 mm and > 3 mm.
British Columbia Cancer Agency
Other
High Dose Rate (HDR)Prostate Brachytherapy With Vitesse tm
Acronym: Vitesse
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03269422
Genital Diseases, Genital Diseases, Male
Basking Ridge, New Jersey, United States
View Trial DetailsNCT05754658
Breast Cancer, Breast Diseases
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT03606837
Genital Diseases, Genital Diseases, Male
Bordeaux, France
View Trial DetailsNCT06540794
Genital Diseases, Genital Diseases, Male
Istanbul, Turkey (Türkiye)
View Trial Details