Correlation Analysis Between Mostcare Parameters and Spontaneous Breathing Trial in Patients After Cardiac Surgery

Cardiac output (CO) monitoring is of primary importance in high-risk surgery and critically ill patients.

Intermittent thermodilution (ThD) by means of a pulmonary artery catheter (PAC) was invasiveness, the occurrence of complications, and inability to estimate CO on a beat-by-beat basis may explain the reduction in routine use. Echocardiography is now widely used. However, a poor acoustic window, inaccurate diameter calculations, and difficulty maintaining the angle of insonation and blood flow within the recommended values may lead to inaccuracy in CO estimation.Pulse contour methods (PCMs) are commonly used as they seem to fulfill most of the characteristics of an "ideal" hemodynamic monitoring system.

Mostcare can continuously and real-time monitor important circulatory indicators such as cardiac output, peripheral vascular resistance index (SVRI), cardiovascular impedance (Ztot), cardiac cycle efficiency (CCE), and maximum pressure gradient (dp/dt MAX). It may help identify the causes of difficulty in weaning patients from ventilators after cardiac surgery.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Department of Critical Care Medicine of pekin union medical college hospital

Beijing, Beijing Municipality, 100730, China

About this study

Cardiac output (CO) monitoring is of primary importance in high-risk surgery and critically ill patients.

Intermittent thermodilution (ThD) by means of a pulmonary artery catheter (PAC) has been used as the reference method and to validate alternative monitoring systems. Its invasiveness, the occurrence of complications, and inability to estimate CO on a beat-by-beat basis may explain the reduction in routine use.

Echocardiography is now widely used in ICUs for the complete assessment of heart function, volume status, and CO measurement. Because it has been well accepted as a first-line diagnostic tool for circulatory failure, it has been proposed as an alternative for ThD to evaluate CO in selected patient populations . A poor acoustic window, inaccurate diameter calculations, and difficulty maintaining the angle of insonation and blood flow within the recommended values may lead to inaccuracy in CO estimation.Finally, training is of major importance.

Pulse contour methods (PCMs) are commonly used in operating rooms or ICUs as they seem to fulfill most of the characteristics of an "ideal" hemodynamic monitoring system.

Mostcare can continuously and real-time monitor important circulatory indicators such as cardiac output, peripheral vascular resistance index (SVRI), cardiovascular impedance (Ztot), cardiac cycle efficiency (CCE), and maximum pressure gradient (dp/dt MAX). It may help identify the causes of difficulty in weaning patients from ventilators after cardiac surgery.

This is a prospective observational study. Patients admitted to the ICU after cardiac surgery and mechanically ventilated for more than 24 hours were monitored for mostcare before attempting to withdraw from the ventilator, and assessment of systemic circulation and cardiac ultrasound was completed.

Patients were given an spontaneous breathing test(SBT) off the ventilator. Mostcare parameters were also recorded. If the SBT experiment was successful the endotracheal tube was removed, if it failed then mostcare monitoring and assessment of circulation and ultrasound were performed again after resumption of mechanical ventilation.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients admitted to the ICU after cardiac surgery
  • mechanically ventilated for more than 24 hours

Exclusion criteria

  • the presence of pathologies that could affect the quality and reliability of the arterial pulse transmission (aortic valve diseases, aortic aneurysm or dissection, thoracic outlet syndrome);
  • arrhythmias;
  • hemodynamic instability;
  • age less than 18 years or more than 80 years

Treatment and study plan

Primary outcomes

  1. The Cardiac Cycle Efficiency (CCE)(unit)

    Time frame: Day1

    The Cardiac Cycle Efficiency (CCE) parameter provided by Mostcare is a comprehensive index of cardiac function that takes into account the mechanical and geometric properties of the heart. It integrates the changes in pressure and volume throughout the cardiac cycle to provide a single value that reflects the heart's efficiency.

    CCE is computed as CCE= Wsys/Wbeat*K(t), where Wsys is the power function from the systolic pressure wave, Wbeat is the power function from the entire cardiac cycle pressure wave, and K(t) is the ratio of mean pressure expected over mean pressure measured.

Sponsors and collaborators

Lead sponsor

Peking Union Medical College Hospital

Other

Registry information

Important dates

Study start
2024
Primary completion
2024
Study completion
2024
First posted
Jan 30, 2024
Registry last updated
Jan 14, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.