CORBIC Cardio-Neuro-Vascular Institute
Medellín, Colombia
NCT Number: NCT01076036
An open-label, prospective, single-arm study is designed to evaluate safety, clinical and technical efficacy of the CorPath 200 System in delivery and manipulation of the coronary guide wires and balloon/stent systems for use in robotically-assisted, percutaneous coronary intervention (PCI) procedures.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Phase 2
Medellín, Colombia
Objective The study objective was to evaluate the safety and technical efficacy of the CorPath 200 System in delivery and manipulation of commercially available coronary guidewires and rapid exchange balloon/stent catheter for use in percutaneous coronary interventions (PCI).
I. Primary Endpoints A. Efficacy Device Clinical Success: Achievement of a < 30% final diameter stenosis after utilizing the CorPathTM 200 System to deliver a PTCA balloon and then stent to the target lesion, and successfully retract the devices without the occurrence of any In-Hospital MACE (Major Adverse Cardiac Event) evaluated at 48 hours post procedure or hospital discharge, whichever occurs first.
B. Safety In-Hospital MACE: Defined as the composite of death (all cause mortality), recurrent MI, and target vessel revascularization (emergent coronary artery bypass surgery [CABG] or PCI) evaluated at 48 hours post procedure or hospital discharge, whichever occurs first.
II. Secondary Endpoints A. Efficacy CorPath Success: Ability to navigate the guide wire and balloon/stent system utilizing the CorPath™ device to the target site without the occurrence of any In-Hospital MACE, evaluated at 48 hours post index procedure or hospital discharge, whichever occurs first.
Subject Clinical Success: Achievement of a <30% final diameter stenosis of target lesion after treatment with PTCA/coronary stent without the occurrence of any In-Hospital MACE, evaluated at 48 hours post-index procedure or hospital discharge, whichever occurs first.
B. Safety:
MACE at 30 Days: Defined as the composite of death, recurrent MI and/or target vessel revascularization (emergent coronary artery bypass surgery [CABG] or PCI) evaluated at 30 days post index procedure.
Adverse Events:
A summary of all adverse events observed in the trial summarized as either serious or non-serious and summarized by attribution.
C. Clinical Utility
Procedure Attributes:
CorPath Device Attributes:
Subjective assessment by the operator of the following device performance attributes:
Material & Methods Corindus obtained approval (from the CORBIC Ethics Committee and INVIMA - Colombian Ministry of Health) in 2009 to conduct the clinical study "CorPath™ 200 System: Coronary Remote Catheterization Feasibility Study" at CORBIC Cardio-Neuro-Vascular Institute, Envigado, Colombia.
The study is a single arm, open label, prospective registry to treat a de novo lesion (2.5 mm - 4.0 mm in diameter, 25.0 mm in length with >50% stenosis) utilizing the CorPath 200 System to deliver, manipulate and retrieve a guidewire and a balloon/stent catheter system.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
General Inclusion Criteria:
Angiographic Inclusion Criteria:
General Exclusion Criteria:
Angiographic Exclusion Criteria:
CorPath™ 200 robotically-assisted percutaneous coronary intervention
Time frame: 48-hrs or hospital discharge, whichever occurs first
The percentage of Participants with <30% final diameter stenosis of the target lesion without in-hospital major adverse cardiovascular events (MACE) (defined as the composite of death, recurrent MI, and target vessel revascularization)
Time frame: Intervention
Successful robotic delivery and retraction of all PCI devices during CorPath PCI procedure.
Siemens Healthineers Endovascular Robotics, Inc.
Industry
CorPath™ 200 System: Coronary Remote Catheterization Feasibility Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05035056
Arterial Occlusive Diseases, Arteriosclerosis
Los Angeles, California, United States
View Trial DetailsNCT06039748
Arterial Occlusive Diseases, Arteriosclerosis
Jieyang, Guangdong, China
View Trial DetailsNCT06614023
Angina Pectoris, Arterial Occlusive Diseases
View Trial DetailsNCT04826172
Arterial Occlusive Diseases, Arteriosclerosis
Aarhus, Denmark
View Trial Details