Continuous Positive Airway Pressure and Oxygen Concentration on Measurement of Rapid Shallow Breathing Index

To compare the rapid shallow breathing index (RSBI) values, the incidence of adverse reactions, and the predictive accuracy measured under 5 different ventilator strategies in the same patient group.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Observational

Primary location

Respiratory Therapy Intensive Care Unit, Taipei Veterans General Hospital

Taipei, 112, Taiwan

About this study

98 ready for weaning patients were included and divided into success (n=71) and failure (n=27) groups based upon their weaning outcome. Before weaning, the RSBI values were determined under the patients disconnecting from the ventilator (RA-no ventilator) and still connecting to the ventilator with 4 different settings (fraction of inspired oxygen (FiO2) 21 or 40% combined with continuous positive airway pressure (CPAP) 0 or 5 cm H2O). The patients were extubated after completing the weaning trials. Successful weaning was defined as patients free from the ventilator for over 48 hours.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • intubated medical patients with mechanically ventilated more than 48 hours
  • clinically ready for weaning
  • Glasgow coma scales were at least 8
  • their ventilator settings were: assist-controlled, pressure support (PS)or synchronized intermittent mandatory ventilation plus PS mode, FiO2 40% or less, positive end-expiratory pressure 5 cm H2O or less, and sensitivity setting on 1 L/min. Their arterial blood gases results were acceptable

Exclusion criteria

  • having ongoing lung or neuromuscular disease and signs of increased intracranial pressure

Treatment and study plan

Primary outcomes

  1. The patients connecting or disconnecting to the ventilators affected the RSBI values but not their predictive accuracies.

    Time frame: Before the patient processing weaning trials

Secondary outcomes

  1. Changes in FiO2 and CPAP settings have no effect on RSBI values but ventilator methods with FiO2 21% have higher incidence of adverse reactions.

    Time frame: Before the patient processing weaning trials

Sponsors and collaborators

Lead sponsor

Taipei Veterans General Hospital, Taiwan

Other Gov

Registry information

Official study title

Effect of Continuous Positive Airway Pressure and Oxygen Concentration on Measurement of Rapid Shallow Breathing Index

Important dates

Study start
2004
Primary completion
2004
Study completion
2005
First posted
Mar 10, 2008
Registry last updated
Mar 10, 2008

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.