NCT Number: NCT00937248

Cone Beam Computed Tomography (CT) (CBCT) With and Without a Customized Vacuum Immobilization Device (CVID)

This study is designed to investigate whether or not the use of a customized vacuum immobilization device (CVID) to immobilize rectal cancer patients undergoing preoperative pelvic radiation therapy improves the positional stability of patients during each radiation treatment. This question is more relevant now in the era of image-guided radiation therapy (IGRT). Using state of the art IGRT technologies such as cone beam CT (CBCT) scanning, assessments of the accuracy of treatment delivery can be made during a course of radiation therapy allowing for patient set-up corrective strategies to be implemented. The use of CBCT scanning may minimize any potential benefit of of a CVID if the patient's pretreatment position can be corrected prior to treatment and our current immobilization strategy results in a stable patient position. While it is seemingly intuitive to assume that the use of CVID results in better patient stability, there is actually little data to support this.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University Health Network, Princess Margaret Hospital

Toronto, Ontario, M5G 2M9, Canada

About this study

Rectal cancer accounts for 5% of all cancers diagnosed in Canada for both men and women between 1995 and 2004 (Public Health agency of Canada _ Health 2004). Preoperative radiotherapy (RT), with or without chemotherapy, is an accepted treatment for patients with locally advanced rectal carcinoma followed by surgical resection (Bosset and Horiot 2001; Sauer, Fietkau et al. 2003; Birgisson, Talback et al. 2005). The current standard treatment at Princess Margaret Hospital (PMH) is preoperative pelvic radiation therapy to a total dose of 50 Gy/25 fractions/5 weeks. The total radiation dose is reduced to 45 Gy/25 fractions/5 weeks when there is a concern about the volume of small bowel within the treatment volume. Radiation therapy is delivered with 5-fluorouracil (5-FU), 225mg/m2/24h, by protracted venous infusion (PVI) or oral capecitabine, 825 mg/m2 BID for 5 weeks, starting the first day and completing the day of last day of radiation therapy.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Any rectal cancer patient who is to receive a 5 week course of preoperative pelvic radiation therapy with or without concurrent chemotherapy
  • Prone treatment position
  • Age 18 years or older
  • Informed consent

Exclusion criteria

  • Inability to provide informed consent
  • Inability to tolerate treatment in the prone position
  • Pregnancy
  • Patients with unilateral or bilateral metallic total hip replacements

Treatment and study plan

prone pillow and simple ankle fixation device

Device

Patients will lie face down (prone) on a soft cushion made of foam under their face and upper chest. Additionally, there is a foam support placed at the ankles.

Customized Vacuum Immobilization Device (CVID)

Device

This device is a bean bag like cushion that is placed from the abdomen to the thighs. When a patient is comfortably lying on this device, air within the bag is suctioned out resulting in an impression or cast of a patient.

Primary outcomes

  1. Comparing the use of a prone pillow and simple ankle fixation device vs. the use of a CVID for immobilization rectal patients during the course of preoperative radiation therapy using KV CBCT for IGRT.

    Time frame: 2 years

Secondary outcomes

  1. quantify interfractional set-up displacements using either of the two devices;determine a standard planning target volume margin; evaluate the role of soft-tissue image matching for IGRT using CBCT.

    Time frame: 2 years

Sponsors and collaborators

Lead sponsor

University Health Network, Toronto

Other

Registry information

Official study title

A Randomized Study Evaluating Set-up Reproducibility Using Cone Beam CT (CBCT) With and Without a Customized Vacuum Immobilization Device (CVID) in Rectal Cancer Patients Treated With Preoperative Pelvic Radiation Therapy

Important dates

Study start
2009
Primary completion
2023
Study completion
2023
First posted
Jul 10, 2009
Registry last updated
Oct 27, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.