NCT Number: NCT02027883
As the indications for Implantable Cardioverter Defibrillator implantation expand, minimizing implant time is critical. Also, patients receiving biventricular ICDs are sometimes more unstable and minimization of sedation time is crucial. Multiple induction attempts, with a 1-Joule shock, can cause disruption in lead position. Therefore limiting the number of attempts will allow for better lead stability throughout the procedure and a more straightforward implant process.
Investigator proposes a detailed documentation of success rates from various Ventriculart Fibrillation induction methods during implant of Medtronic defibrillation capable devices.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Kingsport, Tennessee, 37660, United States
Our clinical experience has found that attempts to induce patients receiving ICDs at implant using the nominal Medtronic T-shock settings are not always effective at inducing ventricular fibrillation. When this results, a change to the parameters for T-shock is made before reattempting to induce ventricular fibrillation in patients undergoing ICD implantation.
Another available induction method is 50 Hz Burst. "The 50 Hz Burst induction is designed to induce VF by delivering a rapid burst of pacing pulses. The amplitude and pulse width of these pulses are selectable, but the pacing interval is fixed at 20 ms."2 If multiple attempts using the T-shock method are unsuccessful, 50 Hz Burst provides an additional method for inducing ventricular fibrillation. It is a less desirable method since it can result in very fine VF that is difficult to identify the initiation of possibly resulting in longer times in VF causing higher defibrillation threshold or in undersensing due to the fine nature of the rhythm.
T-shock has been found to be a fast and reliable method for inducing ventricular fibrillation in ICD implants. Greater success of inducing ventricular fibrillation using the T-shock method has been found when the energy of the T-shock was higher and the coupling interval was shorter. In addition, increasing the shock strength increases the window of vulnerability. For the T-shock method to be most efficient, initial success at inducing ventricular fibrillation, and therefore a reduced number of attempts, is important. This requires a better understanding of the optimal programmed settings for the initial T-shock induction attempt.
Moreover, in recent years, ICD indications have grown to include primary prevention patients. These patients may have different vulnerable periods than patients previously evaluated to develop Medtronic nominal settings.
Our clinical experience has found that the nominal T-shock settings are only effective at inducing ventricular fibrillation approximately seventy-five percent of the time. However, a detailed collection of success rates has not been performed.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Nominal Parameter Set 1 Programming Values for EnTrust
Other names: Medtronic ICDs
Experimental Parameter Set 2 Programming Values
Other names: Medtronic ICDs
Time frame: 2 hours
The primary endpoint is the successful induction of sustained ventricular fibrillation.
Time frame: 2 hours
Determine if any pre-implant patient demographics are factors impacting T-shock success according to parameter settings.
Time frame: 2 hours
Number of participants that were monitored for safety issues, including increased heart rate, blood pressure, decreased oximetry levels, and stable rhythm during the entire procedure.
James Merrill
Other
Comparison of Ventricular Fibrillation Induction Techniques During Medtronic Implantable Cardioverter Defibrillator Implant
Acronym: VF
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03057561
Arterial Occlusive Diseases, Arteriosclerosis
View Trial DetailsNCT01143519
Cancer, Cardiomyopathies
Research Triangle Park, North Carolina, United States
View Trial DetailsNCT07272330
Cardiomyopathies, Cardiomyopathy
Beijing, Beijing Municipality, China
View Trial DetailsNCT01648634
Cardiomyopathies, Cardiomyopathy
Paris, France
View Trial Details