Comparison of Two Needles (ProCore vs EchoTip) for the Diagnosis of Pancreatic Solid Mass Under EUS

The negative predictive value of fine needle aspiration under ultrasound endoscopy (EUS) for the diagnostic of solid pancreatic masses is 70% on average in the current literature with 22 gauge needles. There is a wide variability of this rate across studies (from 38 to 92%). In case of negativity of the biopsy, the risk of missing a pancreatic cancer whose prognosis is severe and extensive treatment, remains important. To improve the sensitivity of EUS echo endoscopy, several methods were used. A new needle (Echo Tip ® HD ProCore ™) has received CE Mark in the field of EUS. This instrument combines the comfortable and handy size of 22 Gauge and innovative design (window lateralized bevel) with in vitro studies obtaining core biopsy. In addition, a single pass through the tumor is achieved with this hand against several (2-3 minimum) with the current hardware. The theoretical goal is to have a tissue material more abundant during the sampling, without increasing morbidity and increase the diagnostic accuracy. A preliminary prospective study with this material has shown interesting results (increase the diagnostic accuracy of 15%).

To determine the diagnostic gain with this new hand, it seemed essential to propose a prospective comparative study (22 gauge needle ProCore ™ versus the old EchoTip ® 22-Gauge) randomized (randomization of the order of the needles) in crossover (on the same lesion) in samples of pancreatic solid tumors. The caliber of 22 gauge is the gauge most often used for punctures under ultrasound endoscopy, resulting in less morbidity. Puncture by the 2 needles on the same injury can limit the effect of variability between patients and thereby have a better power for the investigators study without increasing the risk of complications (the needle ProCore ™ does not require that one pass through the tumor). The study of pancreatic solid tumors is one that poses the biggest diagnostic problem still present in the investigators daily practice. The aim of this study is to compare the diagnostic accuracy of the needle ProCore™ versus EchoTip® in etiological cyto histological diagnostic for pancreatic solid tumors under EUS.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 3

Primary location

Hôpital L'Archet 2, CHU Nice, BP 3079

Nice, 06202, France

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Solid tumor of the pancreas (<50% share or anechoic fluid) to receive a biopsy under endoscopic ultrasonography (EUS)

Exclusion criteria

  • Contraindications to the achievement of an upper gastrointestinal endoscopy
  • Haemorrhagic disease, disorder of hemostasis and coagulation (PT <60%, CaT> 40 sec. and platelets <60000/mm3)
  • Pancreatic cystic mass (fluid quota valued at more than 50% of the mass lesion on imaging)
  • Pregnant or lactating

Treatment and study plan

Puncture with fine needle aspiration under endoscopic ultrasonographic control

Procedure

Puncture of the pancreatic solid mass with fine needle aspiration under endoscopic ultrasonographic control Passage in the same pancreatic mass of first EchoTip HD Procore then EchoTip 22 Gauge or vice versa according to the randomization

Primary outcomes

  1. Diagnostic accuracy of fine needle aspiration Echo Tip® HD ProCore™ versus EchoTip® in the etiological cyto histological in pancreatic solid tumors explored under endoscopy ultrasonography.

    Time frame: 6 months

Secondary outcomes

  1. Immediate morbidity per procedure of both techniques and delayed morbidity (up to D30) of the complete procedure (corresponding to all of the discussion with the punctures of 2 needles).

    Time frame: 2 minutes and 30 days

    Adverse effects (%, number of event for each needle passage) during the procedure or during the follow up period (30 days)

  2. Quality of histological specimen obtained with the 2 needles

    Time frame: 10 days

    Visual analogic scale and Maier score used for this point

  3. Dysfunction in two type of needle biopsy

    Time frame: Day one

    failure or difficulty reports with each needle (%)

  4. ease of puncture between the 2 types of equipment.

    Time frame: day one

    Visual analogic scale

Sponsors and collaborators

Lead sponsor

VANBIERVLIET

Other

Registry information

Official study title

COMPARATIVE STUDY OF DIAGNOSTIC VALUE FOR THE ECHOTIP® PROCORE™ 22 Gauge NEEDLE VERSUS ECHOTIP® 22 Gauge IN THE DIAGNOSIS OF PANCREATIC SOLID TUMORS UNDER ENDOSCOPIC ULTRASONOGRAPHY : THE "PICORE" STUDY

Acronym: PICORE

Important dates

Study start
2011
Primary completion
2012
Study completion
2012
First posted
Nov 24, 2011
Registry last updated
Apr 23, 2014

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.