Skip to main content
OpenTrials
Completed

NCT Number: NCT02122016

Comparison of Two Different Types of Mechanical Ventilation Weaning in Patients in the ICU

Mechanical ventilation is widely used for ICU patients as a lifesaving procedure. However, it is associated with several complications, such as ventilator-associated pneumonia and the increase of hospital morbidity and mortality. To avoid such complications, we need to wean these patients off the ventilator as soon as possible. This must however be done at the right time to avoid other complications, such as the need for re-intubation. For this reason, it is important to have a specific weaning protocol, which will reduce the time on mechanical ventilation, and avoiding the need for re-intubation and other complications. Recently, an argument has developed as to which weaning protocol would be more appropriated, and whether a computer driven weaning protocol could have better results than the conventional weaning protocols focusing on daily screening and daily interruption of sedation followed by a spontaneous breathing test. Our objective is to compare mechanical ventilation times, weaning success up to 48 hours after extubation, re-intubation rates between a group with computer driven weaning protocol (SmartCare) versus a weaning protocol with daily weaning screens and spontaneous breathing trials in ICU patients ventilated for more than 24 hours.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

Hospital Israelita Albert Einstein, São Paulo, Brazil

Loading trial locations.

About this study

Background: Mechanical ventilation (MV) weaning is commonly performed using Spontaneous Breathing Trials (SBT) with pressure support ventilation after a daily weaning screen [1]. Recently there has been an increased interest in automatic weaning trials, which consists of closed-loop ventilation, using ETCO2 monitoring during SBT [1, 2]. So far, there has been no clinical evidence to compare automatic weaning trials with those of SBT.

Objective: To compare MV weaning times between an Automatic Weaning Ventilation System (SmartCare/PS) and SBT groups.

Methods: A randomized, controlled study performed at a general ICU. Adult patients were enrolled who were ventilated for more than 24 hours. Tracheostomies patients, those with neurological conditions, and a Glasgow coma scales lower than 10 were excluded. Patients were randomized to either the control or Smart Care group. All patients were ventilated with a Drager Evita XL (Drager Medical, Lubeck, Germany) ventilator with SmartCare/PS software version 1.1 available for use immediately prior to randomization. The Control group consisted of a daily weaning screen and SBT with pressure support ventilation. If patients tolerated SBT, they were extubated. Smart Care group patients were also submitted to a daily weaning screen, after which they were ventilated with the SmartCare/PS mode. MV and weaning time, maximum inspiratory pressure (MIP), maximum expiratory pressure (MEP), vital capacity (VC), respiratory frequency to tidal volume ration (f/Vt), use of non-invasive ventilation (NIV) post extubation, and re-intubation rate we evaluated.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Recovery from the causes that had led to mechanical ventilation
  • Capacity to initiate a spontaneous breathing effort
  • Spontaneous eye opening and responsiveness even with low doses of sedation
  • Oxygen inspired fraction lower than 50% with oxygen pulse oximeter higher than 95%
  • Positive end-expiratory pressure under 10 cmH2O
  • Hemodynamic stability
  • Vasopressor drugs lower than 0.05mcg/ml/kg

Exclusion criteria

  • Tracheotomized patients
  • Neurological sequels with a poor prognostic (post cardiorespiratory arrest or central neurological injury)
  • Glasgow scale lower than 10

Treatment and study plan

SmartCare

Device

Ventilator with a SmartCare module that is capable of performing a computer-driven weaning trial taking into account patients lung mechanics and exaled CO2.

Conventional weaning protocol

Other

A conventional weaning protocol performed by physiotherapist with a daily weaning screen and a spontaneous breathing trial

Primary outcomes

  1. Weaning time from mechanical ventilation

    Time frame: From June 2011 to April 2012 an 11 month period

    The duration that patient's received mechanical ventilation until they were extubated comparing two weaning protocols (computer driven v daily weaning screen and spontaneous breathing trial).

Secondary outcomes

  1. weaning success

    Time frame: From June 2011 to April 2012 an 11 month period

    Evaluate the rate of weaning success of patients under mechanical ventilation. Success defined as patient not needing re-intubation up to 48 hours after extubation.

  2. re-intubation rate

    Time frame: From June 2011 to April 2012 an 11 month period

    Evaluate the re-intubation rate of patients that were extubated.

Sponsors and collaborators

Lead sponsor

Hospital Israelita Albert Einstein

Other

Registry information

Official study title

Weaning With Smartcare in Mechanically Ventilated Patients in the ICU - a Controlled and Randomized Study

Important dates

Study start
2011
Primary completion
2012
Study completion
2012
First posted
Apr 24, 2014
Registry last updated
Apr 24, 2014

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.