Ankara Etlik City Hospital
Ankara, Etlik, 06170, Turkey (Türkiye)
Location status: Recruiting
NCT Number: NCT07522957
This study aims to compare two commonly used airway devices (I-gel and Air-Q) in children aged 1-10 years undergoing general anesthesia for surgery. These devices help doctors keep the airway open and support breathing during the operation. The study will evaluate how well each device works, how easy they are to place, and whether they cause air to enter the stomach. Ultrasound will be used to safely check the position of the device and detect any air in the stomach. The results of this study may help improve the safety and effectiveness of airway management in children during anesthesia.
Interested in participating?
Request Info1 year–10 year
All sexes
Observational
Ankara, Etlik, 06170, Turkey (Türkiye)
Location status: Recruiting
This study is designed to compare two commonly used airway devices, I-gel and Air-Q, in children aged 1-10 years who are undergoing surgery under general anesthesia. These devices are used by anesthesiologists to keep the airway open and allow safe breathing during the procedure. Although both devices are widely used in clinical practice, their performance and safety in children may differ.
In this study, children will be randomly assigned to receive one of the two devices during anesthesia. The researchers will measure how effectively each device seals the airway, how easy and quick it is to place, and whether it causes air to enter the stomach, which can be an unwanted effect. Ultrasound imaging, a safe and non-invasive method, will be used to assess both the position of the device and the presence of air in the stomach.
All procedures performed in this study are part of standard clinical care, and no additional risks beyond routine anesthesia practice are expected. The information obtained from this study may help doctors choose the most effective and safest airway device for children, thereby improving the quality of anesthesia care and reducing potential complications.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
I-gel Laryngeal Mask Airway:
The I-gel is a second-generation supraglottic airway device with a non-inflatable cuff designed to provide an anatomical seal of the airway. In this study, the device will be selected according to patient weight and inserted following standard clinical practice during general anesthesia. Its performance will be evaluated using oropharyngeal leak pressure measurements and ultrasonographic assessment of gastric insufflation and device position.
Other names: I-gel laryngeal mask airway
Air-Q SP Laryngeal Mask Airway:
The Air-Q SP is a supraglottic airway device with a self-pressurizing, non-inflatable cuff designed to provide effective airway sealing. It will be selected based on patient weight and inserted using standard techniques. Its performance will be assessed using the same parameters as the I-gel, including oropharyngeal leak pressure, ultrasonographic evaluation of gastric insufflation, and device positioning.
Other names: Air-Q SP laryngeal mask airway
Time frame: Immediately after device placement and at the end of the surgical procedure during anesthesia
Measured in cmH₂O after device placement and at the end of surgery using standard anesthesia machine settings (fresh gas flow 3 L/min, APL valve set to 30 cmH₂O).
Time frame: Immediately after device placement and at the end of surgery
Assessed using ultrasonography by measuring gastric antral cross-sectional area (CSA) after device placement and at the end of surgery.
Time frame: Immediately after device placement, after patient positioning, and at the end of surgery
Evaluated using ultrasonography to assess anatomical alignment at predefined time points.
Time frame: At the time of device placement (periprocedural)
Measured in seconds from picking up the device to achieving effective ventilation.
Time frame: At the time of device placement (periprocedural)
Assessed by the operator using a subjective scoring scale (1-4).
Time frame: From device placement until discharge from the Post-Anesthesia Care Unit (PACU), up to 2 hours
Recorded as the occurrence of events such as desaturation, laryngospasm, coughing, vomiting, or blood staining on the device.
Ankara Etlik City Hospital
Other Gov
Effect of I-gel and Air-Q SP LMAs on Oropharyngeal Leak Pressure and Gastric Insufflation in Children: An Ultrasonography-Guided Randomized Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07461779
Anesthesia General, Lung Resection Surgery
Madrid, Spain
View Trial DetailsNCT02930096
Anesthesia General
Poitiers, France
View Trial DetailsNCT07346768
Airway Management, Body Weight
View Trial DetailsNCT04989439
Computed Tomography, Electric Impedance
Vienna, Austria
View Trial Details