NCT Number: NCT02175628
Purpose: This study will evaluate a new ultrasound imaging technology called acoustic angiography. Acoustic angiography uses an ultrasound contrast agent, already FDA approved for use in cardiology, to enhance imaging of blood vessels. Since acoustic angiography uses ultrasound, and not x-rays, the patient is not exposed to ionizing radiation, unlike traditional angiography and mammography. Specific goals will be to evaluate the quality of the images provided by acoustic angiography in the human breast, and furthermore to evaluate whether or not acoustic angiography provides additional diagnostic information over traditional ultrasound which could provide an improvement in assessing breast lesions. Specifically, this additional diagnostic information will hopefully enable us to reduce false positive tests and discriminate lethal cancers from non-lethal disease.
Participants: The investigators are recruiting 60 patients from the UNC Breast Clinic who are undergoing core needle biopsy or surgical biopsy (BIRADS 4 and 5 breast lesions).
Procedures (methods): Acoustic Angiography imaging will be performed in conjunction with standard diagnostic imaging, including b-mode ultrasound . Then, a reader study will be conducted to compare these modalities. Finally, the images will be analyzed with image processing techniques to determine quantitative metrics exhibited by the blood vessel morphology in the images. These metrics will be utilized to develop a "malignancy score" equation to predict malignancy of a lesion.
Looking for future studies?
Notify Me18 year and older
Female
Interventional
Not applicable
Chapel Hill, North Carolina, 27599, United States
Increasing the sensitivity and specificity of diagnostic imaging in patients at high risk for breast cancer could provide substantial clinical benefit by improving diagnosis, preventing over-treatment, and reducing healthcare costs. Acoustic angiography is a new type of contrast enhanced ultrasound imaging which is specifically sensitive to microvascular structure and density. It evaluates tumor micro-vasculature and may provide a powerful prognostic tool for the diagnosis of breast cancer, and eventually for treatment evaluation.
Sixty patients who are to have a clinical surgical breast biopsy based on results from pre-study standard of care (SOC) imaging will be recruited from the UNC Breast Clinic for participation in the study. The primary objective of this single arm study is to compare the sensitivity and specificity of acoustic angiography with traditional b-mode ultrasound in the distinction of malignant versus benign breast lesions. Secondary objectives include a comparison of area under the curve (AUC) for acoustic angiography versus b-mode ultrasound, comparison of radiologist preference for the two imaging techniques for each of 3 lesion characteristics, and quantification of vessel tortuosity based on acoustic angiography imaging results. These metrics will be used to develop a predictive model of malignancy which will subsequently be compared to results from radiology review.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Acoustic angiography imaging involves a research high frequency ultrasound scanner (VisualSonics Vevo 770) and a prototype transducer as well as conventional b-mode ultrasound to guide the location of the imaging. The conventional ultrasound will be conducted just prior to the acoustic angiography for localization. The imaging also requires administration of Definity ultrasound contrast agent.
Acoustic angiography imaging will be performed by trained medical personnel using mild compression to eliminate motion. Total imaging time is estimated to be less than 15 minutes. All image data will be de-identified and transferred for off-line analysis based on a study ID. The research images will NOT be interpreted or analyzed for clinical decisions related to the patient.
Time frame: 1.5 years
To compare (using a reader study) the sensitivity and specificity of acoustic angiography to the sensitivity and specificity of conventional b-mode ultrasound in evaluation of breast lesions
Time frame: 1.5 years
The AUC of acoustic angiography compared to the AUC of b-mode ultrasound
Time frame: 1.5 years
To compare radiologist preference of acoustic angiography to conventional b-mode ultrasound for each lesion characteristic (shape, margins and vascularity)
Time frame: 1.5 years
To quantify vessel tortuosity metrics for the acoustic angiograph images, and to use these metrics to develop a model for predicting malignancy (a model-based malignancy score)
Time frame: 1.5 years
To compare the model-based malignancy score to the acoustic angiography reader study
UNC Lineberger Comprehensive Cancer Center
Other
Comparison of the Sensitivity and Specificity of Acoustic Angiography (Micro-tumor Detection by Quantifying Tumor-induced Vascular Abnormalities) to the Sensitivity and Specificity of Conventional Ultrasound
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04606199
Behavior, Behavioral Symptoms
San Francisco, California, United States
View Trial DetailsNCT05255380
Behavior, Behavioral Symptoms
San Francisco, California, United States
View Trial DetailsNCT03003403
Body Weight, Nutrition Disorders
Durham, North Carolina, United States
View Trial DetailsNCT05408611
Dysmenorrhea Primary, Neurologic Manifestations
Yenişehir, Mersin, Turkey (Türkiye)
View Trial Details