A) For the investigation of Visual acuity, inter-test agreement and the test-retest reliability were used three different visual acuity tests: ETDRS charts, Landoltring chart and Freiburg Visual Acuity Test (FrACt). The examinees passed each visual acuity test twice but the sequence of the visual acuity tests were randomize and so different for each examinee. The examinees were 24 adult Aalen university students (except students of ophthalmic optics in terms 2 - 7) with a minimal distant visual acuity without or with correction of 0.2. Another inclusion criteria was a maximum myopia of sph -2,00 dpt, a maximum hyperopia of sph +5,50 dpt and a maximum astigmatism of cyl 2,50 dpt. The Landolt C was projected in eight-orientations. For the FrACT Test we used two different devices for response input: a modified keypad with Landoltring symbols (FrACTk) and a haptic Landolt device with an adjustable Landoltring (FrACTh). The primary objective was the comparison between FrACTk and FrACTh. The secondary Objective contains the comparison between all visual acuity tests.
B) Background: Landolt Cs and letters are commonly used optotypes. In the explorative study we compare four different ways of applying them: The Freiburg visual acuity test (FrACT) using a keypad and a haptic Landolt device, a Landolt C chart in accordance to ISO 8596 and DIN 58220 with eight-orientated Landolt C and ETDRS charts. The aims of the survey were to determine examinee´s/examiner´s subjective ratings using Visual analogue scales (VAS), the inter-test agreement between the tests and test-retest reliability of the tests, concerning the test duration.
Subjects and Methods: Twenty-four adult examinees with a visual acuity of ≥ 0,2 were included in the explorative study. The visual acuity of one eye was measured monocularly, randomized with regard to the leading/non-leading eye. The subjects passed every visual acuity test twice in a randomized sequence of the visual acuity tests, which is maintained by a pre-specified randomization list, making use of forced choice.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Aalen, Baden-Wurttemberg, 73430, Germany
luminance level 151 cd/m2 , surround luminance level 75 cd/m2 , assessed with luminance meter (IS-110 Laptop Minolta, Tokyo/Japan)
luminance level: 237 cd/m², surround luminance level 85 cd/m²
luminance level: 236 cd/m², surround luminance level 84 cd/m²
luminance level: 380 cd/m², surround luminance level 70 cd/m²
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
maximum myopia sph -2.00 dpt maximum hyperopia sph +5.50 dpt maximum astigmatism cyl 2.5 dpt
Exclusion criteria
Other names: VISUCAT, FrACT, ETDRS Chart, Landolt C
Time frame: July - August, 2014 (1 month)
Comparison of visual acuity measurements, visualized by Bland-Altman plots
Time frame: July - August, 2014 (1 month)
Assessment of inter-test agreement between FrACTh and FrACTk by comparison between these two methods, visualized by Bland-Altman plots
Time frame: July - August, 2014 (1 month)
Assessment of test-retest reliability of FrACTh and FrACTk by repeated measurements, visualized by Bland-Altman plots
Time frame: July - August, 2014 (1 month)
Assessment of examinees´ / examiner´s subjective ratings, using box & whisker plots for analysis of the visual analogue scale (VAS) results
Time frame: July - August, 2014 (1 month)
Assessment of test duration and its comparison, using box & whisker plots and/or Bland-Altman plots
Schiefer Ulrich
Other
Comparison of the Freiburg Visual Acuity Test (FrACT) With the EDTRS- and Landoltring Charts: a) Assessment of the Inter-test Agreement and the Test-retest Reliability b) Analysis of Examinees' / Examiner's Subjective Rating and of Test Durations
Acronym: FEL
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.