Erasme Hospital
Brussels, Brussels Capital, 1070, Belgium
NCT Number: NCT02964663
The purpose of this study was to compare CO measured by two easy to use non-invasive monitors, the esCCO (Nihon Kohden, Tokyo, Japan) to the Volume View (Edwards Lifesciences, Irvine, USA) and to assess their trending ability in patients undergoing cardiac surgery.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Brussels, Brussels Capital, 1070, Belgium
Cardiac output (CO) is a major physiological variable that should be monitored closely during cardiac surgery in order to assess and guide therapeutic interventions so as to decrease postoperative morbidity. The purpose of this study was to compare CO measured by two easy to use non-invasive monitors, the esCCO (Nihon Kohden, Tokyo, Japan) to the Volume View (Edwards Lifesciences, Irvine, USA) and to assess their trending ability in patients undergoing cardiac surgery. After Internal review board approval and written informed consent, 19 patients were included in this study. Before cardiopulmonary bypass (CPB), CO was measured simultaneously using both the esCCO and the Volume View device before and after 3 CO-modifying maneuvers [passive leg raise (PLR), end expiratory occlusion test (EEOT) and positive end expiratory pressure (PEEP) at 10 cm H2O. Five CO values for esCCO and three for volume view were averaged and compared during a one minute period of time before and after each maneuver. The precision error and its 95% confidence interval (CI) that corresponds to the least significant change (LSC) were calculated within this period of time. The Bland-Altman analysis was used to compare bias, precision and limits of agreement (LOA) of both devices. Trending ability of CO changes was assessed by a modified 4 quadrant plot analysis, within angular limits of agreement considered as acceptable when the mean angle between both delta CO was less than 30°.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
comparison of non-invasive monitoring esCCO vs VV on cardiac output measurements
Other names: VV
Time frame: 6 months
CO (L/min) was measured using esCCO and VV before and after 3 CO-modifying maneuvers (passive leg raise, PEEP of 10 cmH20, end expiratory occlusion test. Five CO values for esCCO and three for VV were averaged and compared during one minute period of time before and after each maneuver.
Université Libre de Bruxelles
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05101291
Anesthesia, Cardiac Output, Low
Gothenburg, Västra Götaland County, Sweden
View Trial DetailsNCT02728791
Cardiac Output, Low, Cardiovascular Diseases
Brest, France
View Trial DetailsNCT04871620
Cardiac Output, Low, Cardiovascular Diseases
Nîmes, France
View Trial DetailsNCT05905536
Cardiac Output, Low, Cardiovascular Diseases
Winston-Salem, North Carolina, United States
View Trial Details