Sir Gangaram Hospital
Delhi, 110060, India
NCT Number: NCT06180564
Pilot RCT with 20 patients in both test and control group. In the control group resection & anastomosis was done using the conventional method. In the test group after devascularisation the resection line was marked on the bowel wall and IRT done using a forward looking infra- red camera with a rainbow display. Resection line was determined by a sharp change in colour on the display screen (corresponding to > 30C change in surface temperature) over the visualised bowel wall. Margins were revised if difference between surgeon and IRT determined resection lines were more than 1cm apart. Anastomosis was done as per surgeon's preference.AL was the primary outcome measure. Hospital stay, operative time, blood loss, post-operative complications as per Clavien-Dindo classification were the secondary outcome measures.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Interventional
Not applicable
Delhi, 110060, India
A pilot randomised control study was done on adult patients undergoing elective open and lap-assisted colo-rectal surgery with ileo-colic, colo-colic, colo-rectal and colo-anal anastomoses. Patients who did not consent, who were operated in emergency, pouch surgeries and in whom resection and anastomosis was not performed were excluded.
43 patients operated between August' 2021 to November' 2022 were allocated to test and control group by simple randomisation without blinding. In the test group after mesenteric devascularisation, the site of resection was marked by the operating surgeon. After that IRT was performed using Infra-red thermal imaging FLIR C2 portable camera in the video mode and the images seen in rainbow colour display mode. The bowel segments of interest were examined from a distance range of 6 to 12 inches at the standard operation theatre temperature and humidity. Colour mapping and corresponding temperature changes were used to demarcate vascularized and non-vascularized segments of bowel. IRT-guided resection line was assigned to the place where the greatest temperature "jump" was observed (corresponding to a change of >3oC and a sharp change of colour on the screen). The IRT determined resection line was compared with the position of the resection line determined by the surgeon using conventional method. A difference of greater than 1 cm between the IRT and surgeon determined resection line was classified as non-matching and the margin was revised till the difference was less than 1 cm. The process was repeated at proximal and distal resection margins. In the control group the resection line was determined by conventional visual and palpatory method. In both the groups after resection of bowel, anastomosis was done as per surgeon preference. Diverting loop ileostomy was done on surgeon's discretion. Occurrence of an anastomotic leak (AL) up-to 8weeks post-operatively was recorded as the primary outcome. AL was defined as at-least one of the following (i) Anastomotic defect noted on physical examination. (ii) Anastomotic defect confirmed in the operating room. (iii) Anastomotic defect seen on proctoscopy. (iv) Radiologic evidence of a leak consisting of either a defect in the anastomosis and an adjacent fluid collection or stranding or extravasation of rectal contrast into the extraluminal space. (v) Clinical evidence of leak such as feculent output from abdominal/pelvic drain. Operative time, blood loss, length of hospital-stay, 30-day mortality and post-operative complications as per the Clavien-Dindo scale were the secondary outcome measured.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Elective colo-rectal surgery, Laparoscopy assisted/ Open , Resection anastomosis done -
Exclusion criteria
Emergency, Pouch surgery, Consent refusal, No resection & anastomosis
-
. In the test group after devascularisation of the bowel segment surgeon marked the resection line using their conventional method, then IRT was used to determine the resection line using infra- red camera in rainbow display mode. Resection line was determined by abrupt colour change (corresponds to decrease in temperature >3 degree Celsius) over the visualised bowel wall. Margins were revised if difference between surgeon and IRT determined resection lines were more than 1cm apart.
Time frame: 8 weeks
Anastomotic leak detected clinically or radiologically
Time frame: 8 weeks
All post-operative complications
Time frame: 8 weeks
From the time of surgery to discharge
Time frame: 30 day
Post operative mortality
Time frame: 1 day
From incision to closure
Sir Ganga Ram Hospital
Other
Anastomotic Leak Rates in Patients Undergoing Colo-rectal Surgery With or Without Intra-operative Infra-red Thermography: Pilot Randomized Controlled Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07274098
Colo-rectal Surgery
Canterbury, Kent, United Kingdom
View Trial DetailsNCT07603232
Anorectal Malformation, Anorectal Malformations
Montreal, Quebec, Canada
View Trial DetailsNCT07113717
Colitis, Colitis, Ulcerative
Hillerød, Denmark
View Trial DetailsNCT07467980
Anastomotic Leak, Anastomotic Leak Large Intestine
Nashville, Tennessee, United States
View Trial Details