Hacettepe Üniversitesi
Ankara, altındağ, 06230, Turkey (Türkiye)
NCT Number: NCT07077733
This study aims to compare video laryngoscope (VL), video stylet (VS), and fiberoptic bronchoscope (FOB) in elective endotracheal intubations of patients aged 18 to 65 years, classified as ASA I-II and without predicted difficult airways. The primary endpoints are the incidence of postoperative sore throat and hoarseness, while secondary endpoints include intubation time, first-attempt intubation success, hemodynamic responses, and procedure-related complications. Postoperative sore throat and hoarseness will be assessed at the bedside at the 20th minute and 6th hour following extubation.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Observational
Ankara, altındağ, 06230, Turkey (Türkiye)
Objective: The selection of an appropriate device for endotracheal intubation is essential for successful airway management. Although various publications in the literature compare the techniques used for intubation in terms of their advantages and disadvantages, there remains a lack of consensus regarding the superiority of one method over another. This study aims to compare video laryngoscope (VL), video stylet (VS) and fiberoptic bronchoscope (FOB) devices in patients without anticipated difficult airway undergoing elective intubation, primarily in terms of postoperative sore throat and hoarseness, and secondarily in terms of intubation time, first-attempt success rate, hemodynamic responses, and complications.
Materials and Methods: The study included patients aged 18-65 years, with ASA physical status I-II, who underwent elective surgery under general anesthesia at the operating rooms of Hacettepe University Hospitals, and who had no predictors of a difficult airway. Patients were allocated into three groups: Group VL (n=105) was intubated using the iS3-L Video Laryngoscope (Shenzhen Insighters Medical Technology, Gaung Dong, China); Group VS (n=102) using the iS3-R Video Rigid Stylet (Shenzhen Insighters Medical Technology, Gaung Dong, China); and Group FOB (n=104) using the iS3-C Video Flexible Laryngoscope (Shenzhen Insighters Medical Technology, Gaung Dong, China).
The primary outcome was the incidence of postoperative sore throat and hoarseness at the 20th minute and 6th hour postoperatively. Secondary outcomes included intubation time, first-attempt success rate, hemodynamic responses to intubation, and complications during the procedure.
Sample size calculations were performed using the G*Power 3.1.9.6 (Franz Faul, Universität Kiel, Kiel, Germany) software. To detect at least a 20% difference in the incidence of postoperative sore throat between any two groups with 80% power and a 5% significance level, the required total sample size was calculated as 294 patients. However, accounting for potential exclusions and data loss, a minimum of 102 patients per group was targeted.
This was a non-randomized, comparative clinical study. The anesthesiologist responsible for each case was not interfered with regarding the management of general anesthesia or the method of endotracheal tube insertion.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 6 hours postoperatively
Primary aim of this study is to compare video laryngoscope (VL), video stylet (VS) and fiberoptic bronchoscope (FOB) devices in patients without anticipated difficult airway undergoing elective intubation, in terms of postoperative sore throat and hoarseness at the 20th minute and 6th hour postoperatively.
Time frame: from the beginning to the end of the intubation procedure
The duration between the placement of the airway device, selected by the attending anesthesiologist, into the patient's mouth and the confirmation of successful intubation (as indicated by the appearance of end-tidal CO₂ on the capnograph) was recorded as the intubation time.
Time frame: from the beginning to the end of the intubation procedure
The success of intubation with the selected airway device on the first attempt was recorded; in cases where the first attempt failed, the total number of intubation attempts was noted.
Time frame: from the beginning to the end of the intubation procedure
The patient's hemodynamic changes during intubation were noted
Time frame: from the beginning to the end of the intubation procedure
Complications during intubation were noted
Hacettepe University
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06218836
Infections, Otorhinolaryngologic Diseases
New Delhi, National Capital Territory of Delhi, India
View Trial DetailsNCT07485972
Endotracheal Tube Cuff Pressure, Postoperative Airway Complications
Adana, Turkey (Türkiye)
View Trial DetailsNCT06122324
Postoperative Sore Throat
Kadiköy, Istanbul, Turkey (Türkiye)
View Trial DetailsNCT06713343
General Anesthesia, Insertion of LMA
Ankara, Çankaya, Turkey (Türkiye)
View Trial Details