Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT07703592

Comparison of Manual PAOP and Automatic PAOP (Smart Wedge)

The pulmonary artery catheter (Swan-Ganz) is a standard tool in intensive care for measuring and monitoring the pulmonary artery occlusion pressure (PAOP). The Swan-Ganz IQ™ model also allows automatic measurement to reduce the risk of error (Smart Wedge). However, the concordance between this automatic method and the manual method remains poorly studied in real clinical conditions and may vary depending on certain clinical situations. This study therefore aims to compare the PAOP automatically measured (Smart Wedge) with the manual PAOP measurement at bedside based on data collected in clinical practice.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

About this study

The pulmonary artery catheter (or Swan-Ganz catheter) is a standard tool for measuring and monitoring PAOP in intensive care. It measures PAOP manually, which is considered the gold standard method. The Swan-Ganz IQ™ model also offers automatic measurement of PAOP during inflation of the balloon in the pulmonary artery (Smart Wedge). The ability to automatically measure PAOP would decrease the risk of error. However, the concordance between manual PAOP (reference method) and automatic PAOP (Smart Wedge) remains poorly evaluated by independent data in real clinical conditions. Furthermore, this agreement may vary depending on the clinical situation. In this context, this study aims to compare the manual PAOP measurement and the automatic PAOP measurement (Smart Wedge) based on data collected in the clinical setting.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age ≥18 years;
  • Admission to an intensive care unit;
  • Presence of a Swan-Ganz IQ™ pulmonary artery catheter placed as part of patient care;
  • Measurement of pulmonary artery occlusion pressure (PAOP) performed by the attending clinician as part of patient care.

Exclusion criteria

  • Pregnancy;
  • Court-ordered protective measures.
  • Refusal to participate by the patient's family members or the patient themselves.
  • Cardiac output measurements by thermodilution or by continuous cardiac output analysis that cannot be interpreted.

Treatment and study plan

Swan-Ganz IQ™, Smart Wedge

Diagnostic Test

Swan-Ganz IQ™ is a device that provides continuous measurement of cardiac index by analyzing the right ventricular pressure wave. The "Smart Wedge" module provides an automated estimate of PAPO as well as a signal quality indicator ("wedge index"), designed to assess the reliability of the measurement and alert the operator in the event of an unusable signal. This algorithm underwent regulatory validation based on retrospective data compared to an expert interpretation of selected tracings, leading to its approval for clinical use.

Primary outcomes

  1. Assess the agreement between PAOP values measured by the "Smart Wedge" algorithm and PAOP values analyzed by an expert in patients in shock who are being monitored via a pulmonary artery catheter (Swan Ganz IQ)

    Time frame: 1 day

    The concordance between manual PAOP and automatic PAOP (assessed by the SmartWedge algorithm during the inflation of the ballon in the arterial pulmonary).

Secondary outcomes

  1. Identify situations where there is a risk of discrepancy in the "Smart Wedge" value

    Time frame: 1 day

    Identify situations where there is a risk of discrepancy in the "Smart Wedge" value: mechanical ventilation vs. spontaneous ventilation, high auto-PEEP, mitral regurgitation, arrhythmia.

  2. Assess the variability between PAOP values measured by the Smart Wedge algorithm and those measured by an expert.

    Time frame: 1 day

    Describe the variation and the relationship between the PAOP values measured by the "Smart Wedge" algorithm and those determined by expert interpretation.

  3. Assess the agreement between the PAPO value provided by the "Smart Wedge" algorithm and the PAPO value used in clinical practice, and compare it to the agreement observed between the algorithm and the expert interpretation performed retrospectively.

    Time frame: 1 day

    Evaluate the agreement between the PAPO value provided by the "Smart Wedge" algorithm and the PAPO value used in clinical practice at the patient's bedside (as recorded in the medical record by the attending clinician), and compare this agreement to that observed between the algorithm and the expert reading performed retrospectively.

Study contacts

Contact information is provided by the study sponsor or research team.

Nicolas FAGE

CONTACT

[email protected]

Xavier MONNET

CONTACT

[email protected]

0145213539

Sponsors and collaborators

Lead sponsor

Assistance Publique - Hôpitaux de Paris

Other

Registry information

Official study title

Comparison of Pulmonary Artery Occlusion Pressure (PAOP) Measurements Performed by an Expert Versus Those Obtained Using the SmartWedge Algorithm in Patients Undergoing Pulmonary Artery Catheterization (Swan-Ganz IQ™).

Acronym: SMART-PAPO

Important dates

Study start
2026
Primary completion
2028
Study completion
2028
First posted
Jul 14, 2026
Registry last updated
Jul 17, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.