Skip to main content
OpenTrials
Recruiting

NCT Number: NCT07337499

Comparison of Maglumi X3 SNIBE With Other Analytical Methods in Laboratory Medicine for 25-(OH)D Quantification

The aim of this study is to assess the agreement among the results obtained using the Maglumi X3 SNIBE method and other analytical methods for the measurement of 25-(OH) vitamin D. The comparison between analytical methods is essential for evaluating the analytical performance of different measurement techniques. Assessing the level of comparability between measurements of the same analyte obtained using different methods is fundamental for the harmonization and quality of procedures used in laboratory medicine, ensuring a correct clinical interpretation of results.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Laboratory of Experimental Biochemistry and Advanced Diagnostic

Milan, Milano, 20175, Italy

Location status: Recruiting

Location contact

Giovanni Lombardi, PhD

CONTACT

[email protected]

+390283502222

Giovanni Lombardi, PhD

PRINCIPAL_INVESTIGATOR

Martina Faraldi, PhD

CONTACT

[email protected]

+390283502248

About this study

The analytical methods most commonly used in clinical laboratories and for which harmonization/standardization of procedures is required are immunoassays, which enable the quantification of an analyte.

Currently, the reference method for immunoassays is liquid chromatography tandem mass spectrometry (LC-MS/MS). LC-MS/MS is increasingly used in clinical laboratories. Its high specificity, sensitivity, and multi-analyte capability make it an ideal alternative to immunoassays or conventional high-performance liquid chromatography (HPLC). LC-MS/MS also provides greater flexibility than immunoassays, as LC-MS/MS assays are typically developed in-house. In addition, a single LC-MS/MS run can generate a large amount of quantitative or qualitative data.

All of these methods are essential in clinical diagnostics because they allow the detection and quantification of a wide range of biomarkers, including hormones, proteins, and antibodies across numerous areas of medicine. Despite their widespread use and importance, variability between different methods, within the same laboratory or across laboratories, represents a significant challenge, with considerable impact on results, clinical decisions, and ultimately on patient care. This variability may depend on various factors, including the quality and source of reagents, the quality of calibrators critical for analyte quantification, detection methods, and testing protocols.

Every clinical laboratory is therefore required to assess the agreement of results whenever new instruments or analytical procedures are introduced, compared with a method already in use. Method comparison is indeed one of the principals of the International Standard (ISO 15189:2012) for the accreditation of medical laboratories and of the IVD Directive 98/79 EC, which defines the requirements for in vitro diagnostic devices (IVDs) at the European level.

The comparison of two methods requires defining a maximum acceptable difference between the concentrations of an analyte obtained using the analytical techniques of interest; therefore, two methods may be considered comparable if the differences between the results are below a predefined acceptable limit: the maximum acceptable error. The definition of the maximum acceptable error is based on analytical quality specifications established according to five hierarchical models defined at the 1999 Stockholm Conference:

  • a model based on the evaluation of the effect of analytical performance on clinical outcomes under specific clinical conditions;
  • a model based on the evaluation of the effect of analytical performance on clinical decisions;
  • a model based on the biological variability of the analyte;
  • a model based on published expert recommendations;
  • a model based on the current state of the art (of instruments and/or methods), derived for example from EQA programs.

Therefore, the study will be structured into several phases, beginning with the collection of information on the analytical characteristics and performance of the instruments being compared, verifying method repeatability. For each analyte, the maximum acceptable error will be defined a priori, based on analytical quality specifications, such as analytical imprecision and inaccuracy.

Statistical tests will be performed to assess the error between the analyte measurements obtained using the different methods and, if comparability is not achieved, additional evaluations will be carried out to rule out methodological errors.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Healthy volunteer subjects:

Subjects who sign the informed consent to participate in the study Age ≥ 18 years Employees, in various roles, of the IRCCS Galeazzi-Sant'Ambrogio Hospital

-Patients:

Subjects who sign the informed consent to participate in the study Age ≥ 18 years Patients referred for major orthopedic surgery: hip and knee replacement (bicompartmental and unicompartmental) Patients referred for cardiothoracic surgery

Exclusion criteria

  • Neoplastic diseases (until remission)
  • Grade I, II, and III obesity
  • Age < 18 years
  • Women who are pregnant or breastfeeding, based on self-declaration
  • Individuals unable to understand and make decisions

Treatment and study plan

Blood sampling

Other

No intervention, besides blood sampling for 25-(OH) vitamin D quantification, is required since this study intends to assess the agreement among the results obtained using the Maglumi X3 SNIBE method and other analytical methods for the measurement of 25-(OH) vitamin D.

Primary outcomes

  1. Comparison of 25-(OH) vitamin D quantification with LC-MS/MS and Maglumi X3 SNIBE

    Time frame: The study requires a single time point

    The primary outcome of this study is to evaluate the agreement between the results obtained for the measurement of 25-(OH) vitamin D using the Maglumi X3 SNIBE method and other analytical methods . Serum level of 25-(OH) vitamin D will be measured in 200 subjects enrolled in Ospedale Galeazzi-Sant'Ambrogio and than analyzed using appropriate statistic test to define the maximum acceptable error among the measurements.

Secondary outcomes

  1. Comparison of 25-(OH) vitamin D quantification with Maglumi X3 SNIBE and other immunoassay based analytival methods

    Time frame: The study requires a single time point

    The secondary outcomes of this study are to evaluate the agreement among the results obtained for the measurement of 25-(OH) vitamin D using the Maglumi X3 SNIBE method and other analytical methods . Serum level of 25-(OH) vitamin D will be measured in 200 subjects enrolled in Ospedale Galeazzi-Sant'Ambrogio and than analyzed using appropriate statistic test to define the maximum acceptable error among the measurements obtained using the diffente methods

Study contacts

Contact information is provided by the study sponsor or research team.

Giovanni Lombardi, PhD

CONTACT

[email protected]

+390283502222

Martina Faraldi, PhD

CONTACT

[email protected]

+390283502248

Sponsors and collaborators

Lead sponsor

I.R.C.C.S Ospedale Galeazzi-Sant'Ambrogio

Other

Registry information

Official study title

Comparison of the Maglumi X3 SNIBE Method With Other Analytical Methods in Laboratory Medicine

Important dates

Study start
2025
Primary completion
2026
Study completion
2026
First posted
Jan 13, 2026
Registry last updated
Jan 13, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.