Comparison of Intubation Success Rates of 3 Different Laryngoscope Blade Types in Morbidly Obese Patients

Reusable laryngoscope blades, which are the most commonly used devices for airway management, have been reported to be frequently contaminated and a possible source of infection. Although disposable laryngoscope blades are recommended to reduce the risk of infection, there are studies suggesting increased failed intubation attempt rates.

The major cause of anesthesia-related mortality and morbidity is the failure of airway management. The incidence of difficult airway is reported to be 1-4% in normal population while it ranges up to 12-20% in obese patients. Following the introduction of disposable blades and considering the increased rate of failed intubation in obese patients with these devices, the investigators aimed to make a comparison of successful intubation rates of plastic and metallic disposable blades in morbidly obese patients

Completed

Looking for future studies?

Notify Me

Key information

About this study

Successful airway management is the first and most important step of patient safety in anesthesia practice, and most common reason of morbidity and mortality related to anesthesia is failure to provide optimum airway safety.

Intubation helps the anesthesiologist have complete control over airway by keeping airway open, facilitating control over ventilation, reducing the risk of aspiration and providing safe airway during resuscitation, and laryngoscopes are most commonly used tools for this purpose. Laryngoscope are comprised of a handle and a blade (also contains light source) which are mostly reusable. But these parts are easily contaminated during intubation, creating susceptibility to infection. Some studies report that even handles have a chance of 50% to be contaminated with blood. Insufficiently disinfected blades are also a major source of infection. Laryngoscopes contact with non-intact mucous membranes and blood frequently, thus play an important role in cross contamination. Abramson et al. reported that 1/3 of reusable laryngoscope blades are contaminated with bacteria after multiple uses. Concerns about hygiene and risk of infection (including prion infections) caused many health professionals tend towards use of disposable medical devices. Following their introduction, single use laryngoscope blades have been subject to many studies, and many opinions were discussed in different platforms. In studies in which intubation success rates of metallic reusable, metallic disposable and plastic disposable blades were compared, while some have demonstratedd their success rates to be identical, others concluded that plastic disposable blades were ineffective compared to two other.

Laryngoscopy and endotracheal intubation may not be easily performed in every case. Airway management and endotracheal intubation are easier in non-obese patients compared to obese patients. Short and relatively immobile neck, narrow interincisor distance, hypertrophic tonsillae, uvula and adenoids in obese patients makes intubation more difficult in these patients. Additionally, loss of muscle tonus causes tongue to obstruct airway and epiglottis to touch posterior wall of pharynx, thus obstructing airway further.

The investigators couldn't find any study conducted on obese patients evaluating success rates for intubation of metallic reusable, metallic disposable and plastic disposable blades in the literature. In this study, they aimed to compare intubation success rates of metallic reusable, metallic disposable and plastic disposable blades in intubation of obese patients.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • morbidly obese patients with 18-60 years age

Exclusion criteria

  • less than 3 cm of mouth opening
  • airway pathology
  • restricted head and neck movement
  • expected difficult airway
  • sore throat
  • upper airway infection

Treatment and study plan

Endotracheal intubation

Device

patients were intubated with 3 different blades

Primary outcomes

  1. comparison success rate of intubation in three different blades

    Time frame: 3 minutes after anesthesia induction

    The investigators compared reusable metal, single-use metal and single-use plastic blades for their effectiveness in laryngoscopy and intubation in morbid obese patients.

Sponsors and collaborators

Lead sponsor

Turkish Society of Anesthesiology and Reanimation

Other

Registry information

Official study title

Comparison of Intubation Success Rates of Metallic Reusable Laryngoscope Blades and Metallic/Plastic Laryngoscope Blades in Morbidly Obese Patients

Important dates

Study start
2014
Primary completion
2015
Study completion
2015
First posted
Jul 20, 2020
Registry last updated
Jul 20, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.