NCT Number: NCT00459303
This study is to compare intraindividually the functional vision provided by two different posterior chamber intraocular lenses: AMO Tecnis Z9000 and Alcon SA60AT Acrysoft. To see if the aspherical intraocular lenses provide better functional vision than traditional spherical intraocular lenses.
Looking for future studies?
Notify Me45 year–80 year
All sexes
Interventional
Phase 4
Taipei, Taiwan
In this prospective study, 20 patients with bilateral catarct presenting for cataract surgery are randomly assigned to recieve an aspherical intraocular lens(AMO Tecnis Z9000) in one eye and a spherical intraocular lens(Alcon SA60AT Acrysof)in the other. All surgeries are performed by one experienced surgeon(Fung-Rong Hu,MD)with clear cornea small incision phacoemulsification and in-the-bag posterior chamber intraocular implantation.
The patients are followed for 3 months, and postoperative contrast sensitivity, contrast acuity, corneal & total ocular high-ordered aberrations are measured and compared intraidividually between two different IOL groups.
Outcome Measurement:
Data Analysis:
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
implantation of aspherical intraocular lenses(AMO Tecnis Z9000)during cataract suregry (small cornea incision phacoemulsification, deliver with Monarch II device, in the bag implantation)
Other names: AMO Tecnis Z9000
implantation of spherical intraocular lenses(Alcon SA60AT Acrysof)during cataract suregry (small cornea incision phacoemulsification, deliver with Monarch II device, in the bag implantation)
Other names: Alcon SA60AT Acrysof
Time frame: average data of post-op 3rd, 6th, 12th week measurements
Contrast acuity testing was measured with spectacle correction for the target distance of three meters using a logMAR letter chart (Precision Vision®) represented on a wall-mounted illuminator cabinet. Two types of contrast charts were used, high contrast (Cat.No.2103 SLOAN translucent chart) and low contrast (Cat.No.2132 10% SLOAN translucent chart), and these were tested under both photopic (250 Lux) and mesopic (0.5 Lux) conditions. The contrast acuity tested ranges from 20/160 to 20/20(from worse to best), which equals LogMAR(Logarithm of the Minimum Angle of Resolution)0.9 to -0.3. All of the visual acuity and functional vision testing examinations mentioned above were performed by a single ophthalmologist. The outcomes were recorded as average of three post-operative measurments.
Time frame: average data of post-operative 3rd week, 6th week, 12th week measurements
Contrast sensitivity testing was measured with spectacle correction for the target distance of three meters using a wall-mounted FACT sine-wave grating chart with nine levels of contrast (Stereo Optical Inc.)and five spatial frequency targets (1.5, 3, 6, 12, 18 cycles per degree (cpd)) at 250 lux. The last correct grating seen for each spatial frequency is recorded and translated by the "EYEVIEW™ Functional Analysis Software" into a log contrast sensitivity unit. The outcomes were recorded as average of the three post-operative measurements.
( physiological range of contrast sensitivity: 1.5 cpd : 25~82.5 ; 3 cpd: 30~150 ; 6 cpd: 65 ~ 200 ; 12 cpd: 20 ~130 ; 18 cpd: 6.5 ~ 65 )
Time frame: pre-op & averate data of post-op 3rd, 6th, 12th week measurements
Corneal topography was performed with a TMS-4 corneal tomographer (Tomey, Japan). We used the 31-rings placido-based system that covers 10.9 mm of corneal diameter which is sufficient for the study of aberrations up to the fifth order for 6 mm diameter. Corneal HOAs were described with Zernike polynomials of 3rd- to 5th-order root-mean-square (RMS) of central 6mm diameter using VOLPro 6.89 software (Fa. Sarver and Associates, Carbondale. Ill, USA).
Time frame: average data of post-op 3rd, 6th, 12th week measurements
A Hartmann-Shack aberrometer (Zywave, Bausch & Lomb Inc., Rochester, New York ) was used for measurement of HOAs of the whole eye. The measurements were done under maximal mydriasis with Mydrin-P (phenylephrine hydrochloride 0.5% and tropicamide 0.5%, Santen). The wavefront errors were described using the RMS of Zernike polynomials for total HOA at pupil diameters of 5 mm and 6 mm, primary spherical (Z 4,0) and 3rd-to 5th-order aberration at the pupil diameter of 6 mm.
National Taiwan University Hospital
Other
Intraidivisual Comparison of Functional Vision Provided by AMO Tecnis Z9000 and ALcon SA60AT Acrysof Posterior Chamber Intraocular Lenses
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07735000
Age Related Cataract, Cataract
Peshawar, KPK, Pakistan
View Trial DetailsNCT07605260
Cataract, Eye Diseases
Islamabad, Punjab Province, Pakistan
View Trial DetailsNCT06428955
Cataract, Eye Diseases
Indianapolis, Indiana, United States
View Trial DetailsNCT06111222
Cataract, Eye Diseases
Heidelberg, Germany
View Trial Details