Unit of Orthodontics and Pediatric Dentistry - Section of Dentistry - Department of Clinical, Surgical, Diagnostic and Pediatrics - University of Pavia
Pavia, Lombardy, 27100, Italy
NCT Number: NCT06278116
The aim of the study is to evaluate the most efficient product for the cleaning of Invisalign® clear aligners (Align Technology Inc., San Jose, CA, USA) through objective and subjective assessments after the use of 5 different products. For each aligner, one product is used for 2 weeks until all of them are used, therefore 5 different aligners are required for the study. A periodontal evaluation is conducted to assess variations during the time frame of the study.
Looking for future studies?
Notify Me14 year and older
All sexes
Interventional
Not applicable
Pavia, Lombardy, 27100, Italy
This randomized clinical trial aims to evaluate the efficacy of 5 different products for the cleansing of Invisalign® clear aligners among the followings:
Patients that will sign the informed consent will be enrolled for the study; parents will sign the consent for underage patients.
2 week before the beginning of the orthodontic treatment with Invisalign clear aligners, a professional manual and mechanical removal of supragingival and subgingival deposits of both arches will be performed. At the baseline (T0), the first aligner will be delivered to the patient, that must wear it for 22/24 h except for meals and oral hygiene procedures. One of the 5 cleaning product will be randomly assigned to the patient and toothbrush with silicone bristles (Kalipharm S.r.l., Alba, IT) will be given the cleaning procedures. Patients will be asked to fill in a questionnaire for the subjective appreciation on the cleaning material: the questionnaire presents 19 items evaluating organoleptic and visual characteristics of the aligners and the ease of use of the cleaning method after the first use, after 1 and after 2 weeks. After 2 weeks (T1), patient will be visited again: the questionnaire will be collected, together with the aligner, and a periodontal evaluation on the Ramfjiord teeth will be performed using the following indices: Plaque Index (PI), Bleeding on Probing (BoP), Probing Pocket Depth (PPD), (Gingival Index), BEWE (Basic Erosive Wear Examination), Schiff Air Index. After that, another questionnaire and the following aligner will be given to the patient, another cleaning product will be randomly assigned and another toothbrush will be given. The procedure will be repeated for the following 2 (T2), 4 (T3), 6 (T4) and 8 weeks (T5) until all the cleaning products are tested. All the products will be masked.
JASCO V-750 spectrophotometer (Jasco Corporation, Tokyo, Japan) will be used to evaluate adsorbance for each aligner after the application of the cleaning products. A control value will be calculated using a new clean aligner. The spectrophotometer calculates reflectance values that will be converted in adsorbance values.
Sample size
Sample size was calculated with the following assumptions: ability to detect a clinically relevant difference of 0.0265 in the adsorbance of the clear aligner (primary outcome) of the five groups with an alfa = 0.05 and power = 80%. The assumptions were based on findings of a previous study, with an expected value of 0.190 and a standard deviation of 0.03 for the first group after 2 weeks. Therefore, 20 aligners per each cleaning method were required for the study.
Statistical analysis Statistical analysis will be conducted with R software (R version 3.1.3, R Development Core Team, R Foundation for Statistical Computing, Wien, Austria).
For each variable, Significance for all statistical tests will be predetermined at P<0.05.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The product is masked in a spraying bottle without any labels. Once a day, for 14 days, the patient sprays the product on the aligner before cleaning it with a soft bristle toothbrush for 1 minute. Afterward, the aligner is rinsed under fresh running water.
the product is masked in a transparent bottle without any labels. Once a day, for 14 days, the patient puts the product on the aligner before cleaning it with a soft bristle toothbrush for 1 minute. Afterward, the aligner is rinsed under fresh running water.
the product is masked by deleting all labels on the packaging with a black permanent marker. Once a day, for 14 days, the patient dissolves the tablet in a glass full of warm water (30-35 °C), then the aligner is placed inside it for 5 minutes. Afterward the aligner is rinsed under fresh running water.
the product is masked by deleting all labels on the packaging with a black permanent marker. Once a day, for 14 days, the patient dissolves the crystals in a glass full of warm water (30-35 °C) mixing with a spoon for 20 seconds; then, the aligner is placed inside the glass for 15 minutes. Afterward, the aligner is rinsed under fresh running water.
the product is masked by deleting all labels on the packaging with a black permanent marker. Once a day, for 14 days, the patient puts the product on the aligner before cleaning it with a soft toothbrush for 1 minute. Afterward, the aligner is rinsed under fresh running water.
Time frame: Baseline (T0) and after 14 days from baseline (T1)
The changes in adsorbance values evaluated with a spectrophotometer.
Time frame: Baseline (T0) and after 14 days from baseline (T1)
Through a questionnaire, a subjective evaluation is carried out as regards:
For each of the 19 questions, a mark from 0 (worse mark) to 10 (best mark) will be provided.
Time frame: Baseline (T0) and after 14 days from baseline (T1)
PPD is evaluated with a periodontal probe on the facial and lingual surfaces of the Ramfjord teeth in three sites: distal, central and mesial.
Time frame: Baseline (T0) and after 14 days from baseline (T1)
Site-specific assessment of the presence or absence of gingival inflammation.
Scoring criteria:
Time frame: Baseline (T0) and after 14 days from baseline (T1)
Site-specific assessment of the presence or absence of gum bleeding after the insertion of the periodontal probe for the detection of PPD, detected on 4 sites (mesial, distal, vestibular, palatal/lingual).
Time frame: Baseline (T0) and after 14 days from baseline (T1)
Scoring criteria:
Time frame: Baseline (T0) and after 14 days from baseline (T1)
Scoring criteria:
Time frame: Baseline (T0) and after 14 days from baseline (T1)
Site specific assessment of the amount of plaque on dental surfaces; it is detected on facial and lingual surfaces of the Ramfjord teeth.
Scoring criteria:
University of Pavia
Other
Comparison of Absorbance Values, Sensory Evaluations and Periodontal Effects of Five Different Products for Clean Aligners Cleansing: Randomized Clinical Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05615688
Dental Malocclusion, Malocclusion
Lexington, Kentucky, United States
View Trial DetailsNCT06897852
Dental Malocclusion, Diagnosis
Asyut, Egypt
View Trial DetailsNCT05144555
Dental Malocclusion, Malocclusion
Pavia, Lombardy, Italy
View Trial DetailsNCT04266769
Dental Malocclusion, Malocclusion
Maple, Ontario, Canada
View Trial Details