Comparison of a Novel 22-gauge Core Biopsy Needle

The goal of this clinical research study is to compare the performance of a newly available needle with reverse bevel design (called the EchoTip® Procore™ needle) with standard needles to see which needle gives better diagnostic information for pancreatic lesions.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University of Texas MD Anderson Cancer Center

Houston, Texas, 77030, United States

About this study

An endoscopic ultrasound-guided needle biopsy or FNA is a special endoscopic procedure used to sample lesions within or next to the digestive tract, including the pancreas. The needle is used to collect material for diagnosis. A special lighted, flexible tube called an endoscope is inserted through the mouth, into the stomach and small intestine. The endoscope also has an ultrasound probe at its tip which can be used to see the pancreas, which is located behind the stomach. The doctor will then use the ultrasound to guide the needle biopsy or FNA.

In this procedure, an average of 4 needle passes (needle sticks) is needed to collect enough tissue for diagnosis. However, the number of passes can be higher or lower, depending on the individual lesion and success of the needle passes.

If participant agrees to take part in this study, 2 different needles (the standard straight hollow-core needle and the new EchoTip® Procore™ needle) will be used to sample the pancreas lesion. Two (2) passes will be performed with each needle type and compared. If additional passes are needed for diagnosis, they will not be included in this study. After the first set of needle passes, the doctor may decide that more passes are needed.

Final test results will be taken from the diagnostic results from each needle pass. The results from both types of the needle will be included in the participant's medical record.

This is an investigational study. All needles used in this study are FDA approved and commercially available. Comparing the needles is investigational.

Up to 60 participants will take part in this study. All will be enrolled at MD Anderson.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient age 18 years and older.
  • All patients referred for EUS FNA of endoscopically accessible solid pancreatic lesions.

Exclusion criteria

  • Unable to obtain informed consent.
  • Unable to tolerate the procedure.
  • Women with known pregnancy at time.
  • Patient age less than 18 years of age.
  • Bleeding diathesis
  • Cystic pancreatic lesions
  • Lesion not accessible by EUS guided FNA

Treatment and study plan

Novel 22-gauge Core Biopsy Needle + Standard Biopsy Needle

Device

Two passes performed with the standard 22-gauge or 25-gauge straight hollow core needle and two passes will be performed using the 22-gauge EchoTip® Procore™ needle. All passes will be taken from a single lesion and from the same endoscopic location.

Primary outcomes

  1. Comparison of Diagnostic Adequacy Scores With SST vs. CST for Cytologic Diagnosis Using a 22G Core Needle.

    Time frame: Each EGD EUS-FNA endoscopy procedure takes about 1 hour. Each needle pass takes about 1-2 minutes.

    The main outcome measure of the study was the diagnostic adequacy of the 22Gpc using SST and CST. The cytologic diagnostic adequacy of 22Gpc was also compared to the standard 25 G needle. Each participant underwent 4 study passes, 2 passes with a standard 25 G needle using SST, plus a random assignment to one of two groups for 2 passes with the 22Gpc (1 pass for cytologic and 1 pass for histologic analysis) using SST (group 1) or CST (group 2). Diagnostic adequacy was defined as the ability to procure cytological aspirates or histological core tissue samples that were sufficient for diagnostic interpretation.

  2. Comparison of Diagnostic Adequacy Scores With SST vs. CST for Histologic Diagnosis Using a 22G Core Needle.

    Time frame: Each EGD EUS-FNA endoscopy procedure takes about 1 hour. Each needle pass takes about 1-2 minutes

    The main outcome measure of the study was the diagnostic adequacy of the 22Gpc using SST versus CST on EUS-FNA. The cytologic diagnostic adequacy of 22Gpc was also compared to the standard 25G needle. Diagnostic adequacy was defined as the ability to procure cytological aspirates or histological core tissue samples that were sufficient for diagnostic interpretation. Two cytopathologists, blinded to needle type and technique, reviewed and graded all the study slides. Cytologic diagnostic adequacy of each pass was graded on a semiquantitative scale from 0 to 3 based on sample cellularity. A score of 2 (estimated cell count > 500 cells) or 3 (estimated cell count > 1000 cells) was considered adequate for diagnosis; a score of 3 was most desirable. A score < 2 was considered inadequate. Histologic diagnostic adequacy was graded as either an adequate (score 2 or 3) or inadequate specimen for diagnosis.

Secondary outcomes

  1. Comparison of Diagnostic Adequacy of Single Pass With 22G Core Needle and Standard 25G Needle for Cytologic Diagnosis

    Time frame: Each EGD EUS-FNA endoscopy procedure takes about 1 hour. Each needle pass takes about 1-2 minutes

    The cytologic diagnostic adequacy of 22Gpc was compared to the standard 25G needle. Diagnostic adequacy was defined as the ability to procure cytological aspirates that were sufficient for diagnostic interpretation. Two cytopathologists, blinded to needle type and technique, reviewed and graded all the study slides. Cytologic diagnostic adequacy of each pass was graded on a semiquantitative scale from 0 to 3 based on sample cellularity. A score of 2 (estimated cell count > 500 cells) or 3 (estimated cell count > 1000 cells) was considered adequate for diagnosis; a score of 3 was most desirable. A score < 2 was considered inadequate.

Sponsors and collaborators

Lead sponsor

M.D. Anderson Cancer Center

Other

Registry information

Official study title

Prospective Comparison of a Novel 22-gauge Core Biopsy Needle With Reverse Bevel Design to a Standard Endoscopic Ultrasound (EUS) Guided Fine Needle Aspiration (FNA) Needle for Diagnosis of Solid Pancreatic Mass Lesions

Important dates

Study start
2012
Primary completion
2017
Study completion
2017
First posted
May 15, 2012
Registry last updated
Dec 27, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.