Luis A Gaitini M.D.
Haifa, Israel
NCT Number: NCT02859922
The study compared the Laryngeal Tube Suction (LTS-D) Disposable with the Supreme Laryngeal Mask Airway (SLMA) during spontaneous ventilation. The investigators hypothesized that the LTS-D and the SLMA perform similarly during spontaneous ventilation despite differences in their structural design.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Haifa, Israel
The Supreme Laryngeal Mask Airway (SLMA), (Intavent Orthofix, Maidenhead, UK), and Laryngeal Tube Suction -Disposable (LTS-D, (VBM Medizintechnik GmbH, Sulz, Germany), are second generation single-use supraglottic airway devices (SADs) with gastric access, for airway management in spontaneously and mechanically ventilated patients undergoing general anesthesia.
The SLMA has been compared to the Proseal Laryngeal Mask Airway (PLMA) during mechanical and spontaneous ventilation the LTS II (multiple use version of the LTS-D) with the PLMA.
Recently, the LTS-D and SLMA have been compared when used during pressure controlled mechanical ventilation.
To date, there is no published data comparing the SLMA to the LTS-D during spontaneous ventilation. The investigators hypothesized that the SLMA and LTS-D perform similarly during spontaneous ventilation despite differences in their structural design.
The chief aim of this prospective randomized study was to compare the SLMA and the LTS-D with respect to 1) Oxygen saturation and End Tidal carbone dioxide during spontaneous ventilation, 2) time to achieve an effective airway, 3) ease of insertion, 4) need for interventions to achieve an effective airway, 5) cuff seal (leak) pressure at an intracuff pressure of 60 cm H2O, 6) ventilatory variables during spontaneous ventilation, 7) fiberoptic score, 8) adverse perioperative events.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Laryngeal Tube Suction Disposable
Supreme Laryngeal Mask Airway
Time frame: 30 min
The data were recorded by the Anesthesia Delivery Unit (Datex-Ohmeda, Helsinki, Finland). monitor from starting the establishment of spontaneous ventilation until the device was removed
Time frame: 15 sec
The time was measured in seconds after the anesthesiologist removed the facemask and insert the device and the square-wave capnograph tracing was observed.Two attempts at insertion were permitted. If unsuccessful the patient's airway was managed with a conventional endotracheal tube.
Time frame: After the patient was released from Post Anesthesic Care Unit and 24 hours postoperatively.
Sore throat was assessed subjectively by the patient using the 0-10 Numeric Rating Scale.
Bnai Zion Medical Center
Other Gov
A Comparison Between the Supreme Laryngeal Mask Airway and the Laryngeal Tube Suction During Spontaneous Ventilation: A Randomized Prospective Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02570269
Adverse Anesthesia Outcome
Zurich, Switzerland
View Trial DetailsNCT03015857
Adverse Anesthesia Outcome
View Trial DetailsNCT02884921
Adverse Anesthesia Outcome, Neurologic Manifestations
View Trial DetailsNCT02884986
Adverse Anesthesia Outcome, Neurologic Manifestations
Haifa, Israel
View Trial Details