Dokuz Eylül University, School of Medicine, Department of Anesthesiology and Reanimation
Izmir, Narlıdere, 35320, Turkey (Türkiye)
NCT Number: NCT02163486
Airway management is one of the basic topics in anesthetic practice. Use of endotracheal intubation and face mask are standard methods to maintain an open airway widely adopted for many years. As a result of a search for more appropriate choices from the point of view of effectiveness, reliability and side effects, supraglottic airway devices (SGAD) have been developed.
SGAD's are used for thyroid surgery, ear surgery, carotid endarterectomy, adenotonsillectomy and laser pharyngoplasty, which require a variety of head-neck positions. Changing the head and neck position leads to changes in the shape of the pharynx, which causes variation in the cuff pressure and oropharyngeal leak pressure. Oropharyngeal leak pressure values play a determining role in protecting the airway from high cuff pressure. Additionally it shows that the laryngeal mask is correctly placed and is a sign of the effectiveness of positive pressure ventilation. During surgery head-neck and trunk position may change. As a result there is a need for research evaluating the effect of head and neck position on oropharyngeal leak pressure during SGAD use.
AIM
The aim of this study is to compare the effect of different head and neck positions on the oropharyngeal leak pressure in LMA-Unique and I-Gel applications. Additionally the placement duration, ease and success of these two supraglottic airway devices will be compared.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
Izmir, Narlıdere, 35320, Turkey (Türkiye)
This prospective, randomized, double-blind study will receive permission from the Local Research Ethics Committee and after obtaining patients' informed consent, 103 patients with American society of anesthesiologists (ASA) classification group I-II, between 18-65 years, undergoing elective surgery with indications for supraglottic airway device placement were included in the study.
All patients preoperatively evaluated and ASA and Mallampati classification recorded.
All SGAD's inserted by the same experienced researcher. After placement of laryngeal mask, to standardize postoperative pharyngeal morbidity, cuff pressure (cuff pressure manometer, Ruch, Germany) was monitored.
Exclusion criteria
Patients taken to the operating room were given standard monitoring before anesthesia induction. Patients were preoxygenated with 6 L/min oxygen for 3 minutes through a face mask.
Anesthesia induction was provided by 0.02 mg/kg midazolam, 1-2 mcg/kg fentanyl, 1.5-2 mg/kg propofol and 0.5 mg/kg rocuronium.
All patients have neuromuscular junction monitoring (TOF-GUARD, Biometer International A.S. DENMARK) and when TOF is zero SGAD was inserted with the standard method according to the firm's recommendations.
During SGAD placement, if necessary additional dose of 0.5 mg/kg propofol was given depending on patient reaction. During this procedure cases were ventilated with 100% oxygen though a mask.
STUDY GROUPS:
Group U (UNIQUE): LMA- UNIQUE, inserted according to described standard method
Group I (I-GEL ) : I-GEL, inserted with standard technique according to users manual
For LMA-U the laryngeal mask cuff was inflated so that cuff pressure is less than 60 cm H2O with leak preventive volume. After the operation before the laryngeal mask was removed the cuff pressure was measured again and recorded.
To check SGAD placement bilateral chest movement was observed and capnography be used to confirm a square wave shape. After SGAD was placed oropharyngeal leak test was completed. Oropharyngeal leak pressure were tested in both groups first in neutral head position, then at maximum extension and with head at maximum rotation to the right. In every position the leak measurement was made 60 seconds after position is changed. In order to prevent the SGAD from being seen by the researcher during the tests the patient's head was covered.
Oropharyngeal leak pressure was measured with the ring system expiratory valve closed and 4 L/min flow. To prevent exposure of the lungs to barotrauma, when peak airway pressure reaches 40 cm H2O the expiratory valve was opened .
Leak pressure was evaluated in two ways;
When the sound of the leak is heard, the pressure on the manometer were recorded separately in both situations.
Anesthesia was maintained with 5% O2/air mix with 1.5-2.5% sevoflurane. Systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP), and heart rate (HR) values were measured and recorded immediately before anesthesia induction, immediately before airway device placement and at 1, 2, and 3 minutes after airway placement is checked. The time for successful placement (duration from mouth opening to first successful ventilation), number of attempts, and ease of placement were recorded.
Ease of insertion:
The Mallampati score, type of supraglottic airway device, type of operation and total duration of anesthesia were recorded. Any problems occurring during head and neck positions was noted.
The cuff pressure was measured after surgery while the patient is still in deep anesthesia.
When the patient is conscious the SGAD was removed and the duration of use was recorded (time from insertion to removal).
After the SGAD is removed the presence of blood was evaluated
The patients throat pain, voice loss and difficulty swallowing were evaluated when leaving the recovery room and by telephone 24 hours later by a researcher blind to the insertion technique. To evaluate throat pain the VAS 10 (verbal analogue scale) was used
EXPULSION CRITERIA:
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Before LMA-Unique was inserted, to lubricate the surface in contact with the palate a water-based gel without local anesthetic was applied to completely cover the LMA-Unique cuff.
Other names: Laryngeal Mask Airway-Unique, Teleflex, The Laryngeal Mask Company Limited, Singapore .
Before I-gel was inserted, to lubricate the surface in contact with the palate a water-based gel without local anesthetic was applied to completely cover the I-GEL cuff.
I-GEL: K-Y Jelly® is a registered trademark of Johnson and Johnson Inc
Other names: Group I (I-GEL): I-GEL
Time frame: Immediately after head and neck positioning is completed
The aim of this study is to compare the effect of different head and neck positions on the oropharyngeal leak pressure in LMA-Unique and I-Gel applications. Head and neck positions are limited to neutral, extension and right laterally deviated.
Time frame: Baseline to first successful ventilation, in seconds
Duration from mouth opening to first successful ventilation, in seconds
Time frame: Baseline to first successful ventilation,
The number of attempts until succesful placement of airway device
Time frame: Baseline
Ease of placement:
Time frame: at postoperative 1st and 24th hours
Patients were asked about the presence of sore throat - defined as the presence of constant pain in the throat, voice loss and difficulty swallowing , at postoperative 1st and 24th hours.
Dokuz Eylul University
Other
The Influence of Head and Neck Position On The Oropharyngeal Leak Pressure of LMA Unique ™ and I-GEL™
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07333703
Anaesthesia, Lumbosacral Spinal Stenosis
Samsun, Turkey (Türkiye)
View Trial DetailsNCT06976047
Anaesthesia, Anxiety
Damascus, Syria
View Trial DetailsNCT06724341
Anaesthesia, Anxiety
Damascus, Syrian Arab Republic, Syria
View Trial DetailsNCT04343807
Agnosia, Anaesthesia
Karachi, Sindh, Pakistan
View Trial Details