NCT Number: NCT04907318

Comparison Between a Toric Monofocal and Multifocal Intraocular Lens

The primary objective of the study is to observe the rotational stability of the implant 30 minutes, one day, 6 weeks, 6 months and 12 months after the implant surgery. In addition, the refraction will be measured as it is directly affected in the event of postoperative rotation. The correlation between postoperative rotation and the following parameters will be determined: PEXS, white-to-white, age, axial length, anterior chamber depth. Visual acuities with and without correction and the best refraction to assess the benefit of the implants will also be investigated.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–100 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Vista Alpina Eye Center

Visp, 3930, Switzerland

About this study

This retrospective study will include approximately 90 eyes of patients (adults) receiving conventional cataract surgery having a preoperative corneal astigmatism of 1.0 D or higher. They had been implanted with the Ankoris or T-Flex or FineVision toric implant (about 30/30 and20). So that the groups are comparable, the inclusion and exclusion criteria will be those applicable to a multifocal implant.

Inclusion criteria

for research participants.

  • Cataract (with or without presbyopia)
  • No pre-existing ocular pathology or history of ocular surgery
  • No phacodonesis

PEX patients (pseudoexfoliation syndrome) can be included. Exclusion criteria for research participants. To ensure equivalence of the two comparable groups, the patients with potential postoperative visual acuity less than 5/10, particularly due to an insufficient retinal function or poor corneal condition will be excluded.

In particular the patients with the following pathologies will be excluded:

  • Irregular astigmatism.
  • Cases of uncontrolled glaucoma.
  • Intraocular inflammation.
  • Narrow anterior chambers (2.5 mm).
  • Amblyopia with potential visual acuity less than 5/10.
  • Any corneal pathology potentially affecting topography (e.g., keratoconus).
  • Patients with a history of corneal surgery (especially refractive surgery).
  • Patients with diagnosed degenerative visual disorders (e.g., macular degeneration, diabetic retinopathy or other retina diseases or surgery) with known negative impact on visual function possibly leading to visual acuity levels below 0.5.
  • Patients with a history of ocular trauma.
  • Pathological miosis.
  • Patients with zonular laxity.
  • Patients suffering from chronic uveitis.
  • Patients with monophthalmia. Capsule rupture, intraocular haemorrhage, excessive loss of vitreous, vitreous flare, soft capsules during cataract surgery are also exclusion criteria.

3 - Adopted observation or investigation method This study involves the collection of data in patient records that fall within the normal framework of cataract surgery.

The demographic and clinical data collected will be the yeat of birth and patient's gender, including ocular or general comorbidities (such as diabetes or rheumatoid illnesses) justifying the visual acuity performance.

The preoperative data collected will be: visual acuity, intraocular pressure, cell density of the corneal endothelium, axial length and corneal power in both axes (data required to routinely calculate the power of the implant and entered into the record to understand any postoperative refractive errors).

The intraoperative data will be the power of the implant and any complications, if applicable.

The postoperative data will be data collected during the standard postoperative follow-up performed at 30 minutes, 1 day, one week, 6 weeks, 6 months and 1 year, with patient questioning, slit lamp observation with implant position, measuring intraocular pressure, determining the best refraction and measuring visual acuity with and without correction (near, far and intermediate vision).

4 - Origin and nature of collected personal data Reason for using this data Observations will be obtained by the doctor from patient records. Clinical data will be used to link potential poor postoperative visual acuity and a comorbidity.

Refractive data will help determine the implant stability in the eye in terms of its depth, i.e. in the sagittal plane, and its rotational stability, i.e. coronal plane stability.

Changes will determine its stability in the coronal plane around the visual axis.

The intraocular pressure analysis and slit lamp examination will help determine the eye inflammatory status before and after surgery.

The record of postoperative keratometry values will help determine whether the error or a refractive change caused by the corneal instability or by the change in the implant position.

Who can participate

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Cataract (with or without presbyopia)
  • No pre-existing ocular pathology or history of ocular surgery
  • No phacodonesis

PEX patients (pseudoexfoliation syndrome) can be included.

Exclusion criteria

To ensure equivalence of the two comparable groups, the patients with potential postoperative visual acuity less than 5/10, particularly due to an insufficient retinal function or poor corneal condition will be excluded.

In particular the patients with the following pathologies will be excluded:

  • Irregular astigmatism.
  • Cases of uncontrolled glaucoma.
  • Intraocular inflammation.
  • Narrow anterior chambers (2.5 mm).
  • Amblyopia with potential visual acuity less than 5/10.
  • Any corneal pathology potentially affecting topography (e.g., keratoconus).
  • Patients with a history of corneal surgery (especially refractive surgery).
  • Patients with diagnosed degenerative visual disorders (e.g., macular degeneration, diabetic retinopathy or other retina diseases or surgery) with known negative impact on visual function possibly leading to visual acuity levels below 0.5.
  • Patients with a history of ocular trauma.
  • Pathological miosis.
  • Patients with zonular laxity.
  • Patients suffering from chronic uveitis.
  • Patients with monophthalmia. Capsule rupture, intraocular haemorrhage, excessive loss of vitreous, vitreous flare, soft capsules during cataract surgery are also exclusion criteria.

Treatment and study plan

Cataract surgery

Device

Primary outcomes

  1. To observe the rotational stability of the implant

    Time frame: 6 Months

    Observation of rotational stability of the implant

Secondary outcomes

  1. Visual Acuity

    Time frame: 6 Months

    To assess the visual acuities with and without correction and the best refraction to assess the benefit of the implants

Sponsors and collaborators

Lead sponsor

Beaver-Visitec International, Inc.

Industry

Registry information

Official study title

Retrospective Study Analysing the Results of Toric and Toric Multifocal Intraocular Lens Implantation During Cataract Surgery.

Important dates

Study start
2016
Primary completion
2016
Study completion
2016
First posted
May 28, 2021
Registry last updated
Jun 2, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.