Vista Alpina Eye Center
Visp, 3930, Switzerland
NCT Number: NCT04907318
The primary objective of the study is to observe the rotational stability of the implant 30 minutes, one day, 6 weeks, 6 months and 12 months after the implant surgery. In addition, the refraction will be measured as it is directly affected in the event of postoperative rotation. The correlation between postoperative rotation and the following parameters will be determined: PEXS, white-to-white, age, axial length, anterior chamber depth. Visual acuities with and without correction and the best refraction to assess the benefit of the implants will also be investigated.
Looking for future studies?
Notify Me18 year–100 year
All sexes
Observational
Visp, 3930, Switzerland
This retrospective study will include approximately 90 eyes of patients (adults) receiving conventional cataract surgery having a preoperative corneal astigmatism of 1.0 D or higher. They had been implanted with the Ankoris or T-Flex or FineVision toric implant (about 30/30 and20). So that the groups are comparable, the inclusion and exclusion criteria will be those applicable to a multifocal implant.
Inclusion criteria
for research participants.
PEX patients (pseudoexfoliation syndrome) can be included. Exclusion criteria for research participants. To ensure equivalence of the two comparable groups, the patients with potential postoperative visual acuity less than 5/10, particularly due to an insufficient retinal function or poor corneal condition will be excluded.
In particular the patients with the following pathologies will be excluded:
3 - Adopted observation or investigation method This study involves the collection of data in patient records that fall within the normal framework of cataract surgery.
The demographic and clinical data collected will be the yeat of birth and patient's gender, including ocular or general comorbidities (such as diabetes or rheumatoid illnesses) justifying the visual acuity performance.
The preoperative data collected will be: visual acuity, intraocular pressure, cell density of the corneal endothelium, axial length and corneal power in both axes (data required to routinely calculate the power of the implant and entered into the record to understand any postoperative refractive errors).
The intraoperative data will be the power of the implant and any complications, if applicable.
The postoperative data will be data collected during the standard postoperative follow-up performed at 30 minutes, 1 day, one week, 6 weeks, 6 months and 1 year, with patient questioning, slit lamp observation with implant position, measuring intraocular pressure, determining the best refraction and measuring visual acuity with and without correction (near, far and intermediate vision).
4 - Origin and nature of collected personal data Reason for using this data Observations will be obtained by the doctor from patient records. Clinical data will be used to link potential poor postoperative visual acuity and a comorbidity.
Refractive data will help determine the implant stability in the eye in terms of its depth, i.e. in the sagittal plane, and its rotational stability, i.e. coronal plane stability.
Changes will determine its stability in the coronal plane around the visual axis.
The intraocular pressure analysis and slit lamp examination will help determine the eye inflammatory status before and after surgery.
The record of postoperative keratometry values will help determine whether the error or a refractive change caused by the corneal instability or by the change in the implant position.
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
PEX patients (pseudoexfoliation syndrome) can be included.
Exclusion criteria
To ensure equivalence of the two comparable groups, the patients with potential postoperative visual acuity less than 5/10, particularly due to an insufficient retinal function or poor corneal condition will be excluded.
In particular the patients with the following pathologies will be excluded:
Time frame: 6 Months
Observation of rotational stability of the implant
Time frame: 6 Months
To assess the visual acuities with and without correction and the best refraction to assess the benefit of the implants
Beaver-Visitec International, Inc.
Industry
Retrospective Study Analysing the Results of Toric and Toric Multifocal Intraocular Lens Implantation During Cataract Surgery.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07735000
Age Related Cataract, Cataract
Peshawar, KPK, Pakistan
View Trial DetailsNCT07605260
Cataract, Eye Diseases
Islamabad, Punjab Province, Pakistan
View Trial DetailsNCT06428955
Cataract, Eye Diseases
Indianapolis, Indiana, United States
View Trial DetailsNCT06111222
Cataract, Eye Diseases
Heidelberg, Germany
View Trial Details